Post Buy Requirement
BL

Bergen LED and Solar Products Pvt. Ltd.

Verified Add Review

PV Grid Connected

Together with their range of accessories, StecaGrid inverters represent an innovative family of inverter solutions for grid-connected solar power systems. Whether being used in a small solar power system for a single-family house, or an elaborate combined solution for an industrial complex, Steca grid-feeding inverters all have one thing in More..

Stecagrid - Coolcept-x

Stecagrid 1500xstecagrid 2000xstecagrid 2500xstecagrid 3010xstecagrid 3600xstecagrid 4200x highest efficiency with longer service life the high efficiency results in a peak efficiency of 98.6 % and a european efficiency of up to 98.3 %, which results in less lost power that must be dissipated into the environment. This improves your yields. In addition to this, a new and unique cooling concept inside the inverter ensures an even distribution of the dissipated heat and a long service life for the device. product design and visualisation the stecagrid has a graphical lcd display for visualising the energy yield values, current performance and operating parameters of the system. Its innovative menu allows individual selection of the various measurements. The guided, pre-programmed menu allows easy final commissioning of the device.
View Complete Details

StecaGrid Coolcept X 3203

Stecagrid 3203x, stecagrid 4003x, stecagrid 4803x, stecagrid 5503x inverter topology the coolcept inverter topology was first implemented in the singlephase stecagrid. It achieved optimum efficiency ratings thanks to the innovative switching concept. The three-phase coolcept-x inverters also benefit from the advantages of this switching concept. The three-phase topology is fully reactive current capable and therefore set up to meet demands that may be made in future as well. always symmetrical the advantage of three-phase feeding is that the produced solar capacity is always symmetrically distributed on all three power conductors to the public power grid. This is the case across the whole output range offered by these inverters. The symmetrical feed-in is very much in the interests of the power supply companies, and is also compatible with domestic three-phase consumption.
View Complete Details

Stecagrid - Coolcept

Stecagrid 1500, stecagrid 2000, stecagrid 2500, stecagrid 3010, stecagrid 3600, stecagrid 4200 highest efficiency with longer service life the high efficiency results in a peak efficiency of 98.6 % and a european efficiency of up to 98.3 %, which results in less lost power that must be dissipated into the environment. This improves your yields. In addition to this, a new and unique cooling concept inside the inverter ensures an even distribution of the dissipated heat and a long service life for the device. product design and visualisation the stecagrid has a graphical lcd display for visualising the energy yield values, current performance and operating parameters of the system. Its innovative menu allows individual selection of the various measurements. The guided, pre-programmed menu allows easy final commissioning of the device.
View Complete Details

Stecagrid Coolcept 3203

Stecagrid 3203 stecagrid 4003, stecagrid 4803, stecagrid 5003 stecagrid 5503, three-phase grid inverterhighest efficiency at all input voltagessuitable for use in indoor areas (ip 21)lightweight at only 10 kg inverter topology the coolcept inverter topology was first implemented in the singlephase stecagrid. It achieved optimum efficiency ratings thanks to the innovative switching concept. The three-phase coolcept-x invertersalso benefit from the advantages of this switching concept. The three-phase topology is fully reactive current capable and therefore set up to meet demands that may be made in future as well. Always symmetrical the advantage of three-phase feeding is that the produced solar capacity is always symmetrically distributed on all three power conductors to the public power grid. This is the case across the whole output range offered by these inverters. The symmetrical feed-in is very much in the interests of the power supply companies, and is also compatible with domestic three-phase consumption.
View Complete Details

StecaGrid 8000+ 3ph And StecaGrid 10000+ 3ph

Always symmetricalthe advantage of three-phase feeding is that the produced solar capacity is always symmetrically distributed on all three power conductors to the public power grid. This is the case across the whole output range offered by these inverters. When designing a system, the laborious avoidance of an asymmetry of more than 4.6 kw through the appropriate selection of separate inverters is thus dispensed with. Symmetrical feeding is greatly in the interests of energy supply companies. Lengthy discussions with such companies are therefore a thing of the past. long service live while the voltage passes through zero on the grid-feeding phase, single-phase inverters must temporarily accommodate all energy supplied by the solar modules within the device. This is usually realised by electrolytic capacitors. These components influence the service life of an electronic device, due to the possibility of drying out. With three-phase inverters, energy is fed into the grid on at least two phases at all times. Thus, the necessity of intermediate storage of energy in the device is greatly reduced, which is of benefit to the system operator with regard to a longer service life.
View Complete Details

Solar System Data Logger

Data loggers by solare datensysteme are sought-after specialists for optimised remote monitoring of photovoltaics systems. The combination of stecagrid inverters with solar-logtm now guarantees complete monitoring of your photovoltaic system: all operating parameters, status and error messages of the connected inverters can be viewed simply and reliably. That guarantees maximum yield from your system at all times. advantages at a glance a. Guaranteed yield via comprehensive system monitoring and a wide range of alarm options b. Web-based software no need to install programmes c. Clear presentation of the yield and system values in graphs and tables d. View data via internet connection anywhere, any time e. Optional recording, calculation and optimisation of electricity consumption f. Comprehensive range of accessories - provides many other functions
View Complete Details

StecaGrid SEM

Smart Energy Manager for coolcept, coolcept-120, coolcept-x, StecaGrid 8000+ 3ph and 10000+ 3phThe feed-in management solutionIn Germany, photovoltaic systems require feed-in management. To this end, ripple control receivers of the respective grid operators are installed. These ripple control receivers transmit a reduction signal from the grid operator whenever the system has to be throttled due to grid overloads. StecaGrid SEM is the easiest way to connect your StecaGrid inverter to the ripple control receiver. StecaGrid SEM evaluates the relay outputs of the ripple control receiver and transmits the signals via the Steca solar bus (or Steca RS485 bus) to the connected inverters. SEM stands for Smart Energy Manager Easiest installation StecaGrid SEM can be installed in the switching cabinet right next to the ripple control receiver. The casing features a dimensioning typical for switching cabinets and can be mounted onto a top-hat rail. Its width is 4 HP. Direct power supply at 230 V. A mains adapter plug or an external direct current power supply are not required. Easily accessible service interface All connected StecaGrid inverters can be accessed via a USB interface on the StecaGrid SEM. Connection to a PC is possible via a standard USB cable. The interface is on the front side of the casing the cover does not need to be removed in the switching cabinet. Other functions As of firmware version 3.x, StecaGrid SEM offers additional functions: data can be read from an energy meter via a S0 interface. This allows for a distinction between the share of PV energy used at home and that fed into the grid. With this measurement data, StecaGrid SEM monitors the house connection and ensures that no more than 70% of the systems output is fed into the grid. If required, it accurately reduces the output of the connected inverters.
View Complete Details

StecaGrid Portal

Free web portal for system monitoring Plug and Play When the Ethernet interface of the coolcept inverter is connected to a router, the data from the data logger of the inverter is sent directly to the StecaGrid Portal. Setting up the portal is easy: Follow the link below to the system data entry mask. In addition to system output, the modules used and the location of the system, the serial numbers of the installed inverters are queried. On the StecaGrid Portal, up to 5 coolcept* and coolcept-x inverters can be combined to one system. The data of the individual devices are added up and displayed as a complete system. Free use for two years If the system operator agrees to having his system data published on www.solare-energiewende.de, the StecaGrid Portal (offered in collaboration with meteocontrol) can be used free of charge for two years. Afterwards for further optional use, which is not free of charge, he will receive an offer. Clear presentation of yield data The software interface is very clearly structured. In addition to the system data, yield data is displayed in daily, weekly, monthly and annual profiles. A scale evaluates current yield data of the system in comparison to values from other systems in the same region. This allows the user to determine at a glance whether the systems yield lies above or below the regional average. The display also shows the users environmental contribution in terms of CO2 saved due to yields. Smart networking Monitor the output of your PV system for free with the StecaGrid Portal. With the intuitive user interface, you can access your yield data anywhere and at any time even from your smartphone or tablet PC.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us