Post Buy Requirement
BP
Agra, Uttar Pradesh, India
Verified Add Review

Generators #1123709

Mini Generator

  • Red Silver
  • Brand Name VIDHATA
We offer mini generator.- 3kva mini generator- diesel operated- fuel cons. 600gms per hour.- small size(portable)- no vibration- maintenance free- 1year warranty- export quality product- 100% genuine spare parts- made in india
View Complete Details

Dc Generator

  • Creator gensets from country AC GENSET
  • For N+1 redundancy, peak load demand, and site expansion, multiple DC generators can be operated at the same time and power outputs can be paralleled. It is impractical to parallel AC generators for these applications; therefore they must be over-sized for peak load demands and future expansion. Small loads can cause the engine to “wet stack”.
  • DC generator backs up both utility power and the rectifier bank. rectifier bank. AC generators back up only utility power. If the rectifier fails, the site is down.
  • Backing up power board reduces N+1 redundancy demand on the number of rectifier modules. This lowers the purchase and operational costs. N+1 redundancy of rectifier modules within a power board increases site capital and operating cost.
  • The battery charger or rectifier and the transfer switch for both prime power and solar hybrid applications can be eliminated. Fuel consumption is reduced, and reliability is greatly increased. Rectifiers, transfer switch and controls add considerably to the purchase, installation, and maintenance costs.
  • Variable engine speed option automatically adjusts to meet battery charging and load requirements, providing up to 40% savings in fuel. Engine speeds can vary without affecting voltage regulation. Engine must run at fixed speeds in order to maintain 60 or 50Hz frequency. Engine speed control provisions add to maintenance and reliability problems. Running engine without load shortens engine life.
  • Continuously running the DC generator during long power outages can be avoided in order to conserve fuel and reduce maintenance. The generator can charge the battery, then shut down and begin cycle again. The cumbersome design of an AC Generator/ transfer switch/rectifier system make frequent cycling undesirable.
  • With VIDHATA ’s high efficiency alternator we are able to use smaller horsepower engines, which produce lower acoustic noise. Smaller engines also facilitate installation permits on sites where the regulations are based on horsepower and noise. Combined with the rectifier power losses and the rectifier and air conditioning current surges during startup, the engines and alternators on the AC sets require over sizing. Engines are also oversized to assist in output frequency regulation.
  • A DC generator can “come on line faster than an AC generator. This allows a reduction in the size of the battery bank. Reducing the battery bank size lowers procurement and replacement costs. From experience, larger battery banks are required for AC generator backup systems.

Generator using its bush less / AVR Alternator technology in 2008. Since then numerous organizations have performed extensive testing on our generators VIDHATA assembles the genset to meet its clients requirements by adding the appropriate diesel engine to our DC alternators. The engines are available in either a liquid or air-cooled version. VIDHATA has designed this DC alternator incorporating state-of-the-art technologies and all new tooling to meet the increased performance demand for.

  • Low Maintenance
  • Low EMI Emissions
  • Very High Quality Electrical Output
  • Light Weight
  • Low Fuel Consumption
  • Low Acoustic Noise
  • High and Low Ambient Operation (-40 to 125 F)

VIDHATAPower has met these performance goals through an integrated engineering effort involving detailed analysis of engine, voltage regulator, field coil, magnet, stator, rotor systems output voltage and current.

SPECIFICATIONS

  • DC output 12 volts, 200 Amps
  • DC Voltage regulated at 1 Volt from no-load to full load
  • Dc Voltage will reduce drastically after the load current reaches its rated current & hence protecting generator & Engine from over load
  • Seperately Excited, Brushless, Provided with class H Insulation, Temp. rise limited to Class F. Suitable for an ambient temperature of 40C
  • D.C. Alternator for recharging battery banks. This is not an automotive style alternator because of their poor efficiency
  • 200 amps DC for recharging battery banks, DC generator is the most efficient and least cost solution
  • Require 5 h.p Prime mover at 1500 RPM ENGINE suitable to make a DC generator
  • We can supply complete DC generator close coupled or coupling type both with water cooled and air cooled engines

LOW MAINTENANCE AND HIGH RELIABILITY

  • The unique alternator design allows us to turn the engine at low speeds, thereby extending engine life.
  • The voltage regulator has automatic governing at high electrical load demands the regulator automatically increases engine RPM; at low loads the engine speed is automatically decreased.
  • VIDHATA Powers alternator has no: brushes, slip rings, There are no alternator parts to wear.
  • There are no electronic parts (diodes, etc.) nor electrical connections inside the alternator. There is nothing to short or vibrate loose inside the alternator.
  • The alternator is almost impossible to damage electrically. The outputs can be shorted for minutes without damage.
  • The output current is monitored by the voltage regulator through a current transducer. The voltage regulator has an adjustable current limit on the output. It is virtually impossible to overload the alternator.
  • VIDHATA Powers alternator should have an life of exceeding 50000 hours
  • The engine is protected against: over-temperature, low oil pressure, over-speed, (OPTIONAL).
  • The alternators rotor is dynamically balanced to improve the engines bearing life.

LOW FUEL CONSUMPTIONThe VIDHATA alternator has an efficiency of between 75 to 85% versus 55 to 70% for other DC alternators. Consume only 700 gm diesel in 1 hr.

HIGH AND LOW AMBIENT OPERATION

  • During starting the regulator keeps the field current off. This feature coupled with the small light weight rotor provides a minimal load on the starter motor.
  • For low ambient temperatures (-40 to 10 F) cold starting aids are available.
  • The higher alternator efficiency allows the engine to run cooler in high ambient temperatures. The increased alternator efficiency reduces the mechanical load on the engine which then reduces the engines cooling requirement.
OPTIONS

ENGINE STYLES

  • Diesel Engine: either air-cooled or water-cooled.

VIDHATA DC GENERATORS ARE MORE EXPENSIVE TO PURCHASE THAN AC GENERATORS BECAUSE

  • Our alternators uses a high frequency design (360Hz) that reduces weight, size, and greatly improves the quality of electrical power. The high frequency design requires more labor to wind the stator. Typical AC generators are only 50 or 60 Hz.
  • The stator has a 6-phase design to also improve electrical quality and the torque ripple on the engine for better fuel economy. The 6-phase design requires more labor to wind the stator. Standard AC generators are only single or three phase.
  • The VIDHATAs DC generator set is optimized to produce a high current, low voltage power output for charging batteries and powering DC loads directly. The AC generator is optimized for a high voltage, low current output and requires an external power supply or battery charger to convert AC into DC. The low voltage, heavy current windings are more expensive to wind.
  • VIDHATAs DC generator is very corrosion resistant. We make extensive use of stainless steel fasteners and coated aluminum materials. Certain components must be constructed of steel due the magnetic properties; here we coat with high temperature coatings and/or Cadmium (CAD) plating. Corrosion resistance is important for installations in marine or humid environments or exposed to agricultural and garden chemicals. This construction is not typical of AC generators.
  • VIDHATA uses the very best magnetic wire in an HML grade for a class H rating. This facilitates long life in warm or dusty climates.

Why use DC Generators for Telecommunications, Solar, UPS, Backup, Prime Power.There is not a single universal reason why all applications should choose a DC generator over an AC generator. There are, however, specific reasons for each project or a combination of reasons that favor the DC generator. Some of which include.

APPLICATIONS IN GENERAL (INCLUDING SOLAR/WIND HYBRID, PRIME POWER, AND BACKUP)

  • The DC generator system is designed and optimized to deliver the high currents at low voltages required for battery charging and operating DC loads. No battery chargers or power supplies are required.
  • DC generators do not require a transfer switch. Transfer switches lower system reliability.
  • In prime power applications the DC generator lowers the overall cost of the system.
  • Certain AC generators and switch mode power supplies are incompatible. These AC generators have voltage regulators that cannot regulate voltage due to the current pulsing load of the switch mode power supplies. VIDHATA DC generators when connected to a battery do not suffer this incompatibility.
  • DC generators are more fuel-efficient. Site operators want the longest run time with the least amount of fuel on site.
  • VIDHATAs DC generators are simpler in design, have considerably less maintenance and are more reliable than AC generators. Propane carburetion and electronic speed governors require frequent calibration and testing. If the propane carburetion, ignition system, or governor speed control should develop a problem, alternator voltage regulation and frequency control will fail. Some equipment powered by the generator will be damaged, other equipment may survive. How many of your AC loads can tolerate a wide swing in frequency?.
  • VIDHATAs DC generators have a current limit control to prevent the alternator from overheating and the engine from stalling during shorts or overloads. This feature is extremely important in battery charging because a battery in a low state of charge can demand more power than the generator or battery charger can manage. VIDHATAs DC generators will continues to supply power under current limit control, allowing the battery to increase its charge and drop its current demand. The AC generator uses a fuse or circuit breaker to protect against shorts and over current so the battery fails to get charged if it is overly discharged. The additional problem is that for remote sites a person is required to visit the site to replace or reset the fuse or circuit breaker and devise a means where the batteries can be brought to a state of charge where the batteries can take over.
  • VIDHATA DC generators can be connected in parallel and load share. Paralleling these small AC generators is not practical. In many projects there are concerns about future site expansion and given load estimates are sometimes understated.
  • Maintainability. DC generators use smaller engines that can be lifted by hand and transported to a shop for repair. The high-level generator mechanics are not required, or their expensive travel time to the site.
  • AC generators are typically oversized to handle starting currents of motors and to provide light enough engine loads to facilitate speed regulation. Engines that are lightly loaded build up carbon around the valves and exhaust lines (wet stacking) this creates additional engine maintenance.
  • DC generators are considerably smaller in size and use smaller horsepower engines. This facilitates both roof mount installations and installations inside the small shelters, as well as the required permit process.
  • DC generator lowers the costs to install and operate. It is smaller in size and requires less site support. Transport to the site and installation is facilitated because: smaller shelter and concrete pads can be used, elevator transport to roof rather than crane, smaller helicopters or vehicles for transport. Fuel consumption is lower, so cost to transport fuel to the site is lower (transportation of the fuel to the site can be very expensive).
  • Engines need a warm up period before they are able to provide full power, for an AC generator this translates to providing a stable frequency and voltage. VIDHATA s DC generator can deliver power at a reduced level immediately after starting, then switch to full power after warn up. Also a cold engine can exhibit speed fluctuations, which has no effect on VIDHATA s DC generators.

UPS SYSTEMS

  • VIDHATA s DC generators connect direct to the battery bank so there are fewer problems with on site permitting. Many inspectors and utilities are concerned with isolation of the AC generator from the utility grid. Using a DC generator there should be no questions on isolation from the inspectors.
  • VIDHATA s DC generator can provide regulated charging to the battery and is unaffected by the pulse currents of the switch mode inverter.
View Complete Details

Tractor PTO Shaft Operated Generator

Tractor PTO shaft Operated Generator for driving submersible pumps for IrrigationVIDHATA range of Tractor Operated Generators is available in rotating field. These Tractor Operated Generators are self-excited and self-regulated in semi-brushless and compounding system. Made from the finest quality rolled steel with welded feet and heavy duty cast iron construction, the electric performance gives a voltage regulation and adjustment within a range of 5% plus/minus. Our generators are rated for single or three phase operations apart from customized requirements offered. Backed by team of adroit professionals, we are offering a qualitative range of Tractor Driven Generator Set that are best for operating farm electric motors where electric power is not available or voltage are too low or only few weeks using of pumps where electric grid power is expensive, It is fabricated as per the latest technological quality approved raw materials under the supervision of our skilled technocrats. Vidhata manufacture and exporter of Tractor Driven Generator Set in various sizes & designs and can also be custom designed as per the clients demands.

OPTIONAL CONTROL PANEL AND PTO SHAFT ARE PROVIDED WITH PRODUCT

  • We supply various size of belts and pulley and PTO SHAFT to suit various tractors RPM 540 , 750, 1000,
  • COMPACTABLE TRACTORS FOR VIDHATA PTO OPERATED TRACTOR GENERATORS / GENSET
  • Landani, Angad Tractors, Balwan Tractors, Eicher, Escorts, Farmer Tractor, HMT Tractors, Indo Farm, John Deere
  • Mahindra, New Holland Fiat India, Sonalika , Standard, TAFE

KVA (MODEL) SUITABLE FOR PUMP HP REQUIRED PRIME MOVER
10  / PTO V 5 -7.5 HP MONOBLOCK / SUMERSIBLE PUMP 15 TRACTOR PTO
15 /  PTO V 10 HP MONOBLOCK / SUMERSIBLE PUMP 20 TRACTOR PTO
20 / PTO V 10-12.5 HP MONOBLOCK / SUMERSIBLE PUMP 25- 35 TRACTOR PTO
25 / PTO V 12.5 – 15 MONOBLOCK / SUMERSIBLE PUMP 35 TRACTOR PTO
30 / PTO V 12.5 -17  HP MONOBLOCK / SUMERSILE PUMP 35 -41 TRACTOR PTO
35 / PTO MAXO 12.5 -20 HP MONOBLOCK / SUMERSILE PUMP 35 TO 50 TRACTOR PTO
40 / PTO V 20   HP MONOBLOCK / SUMERSILE PUMP 50 -60 TRACTOR
50 / PTO V 20-25  HP MONOBLOCK / SUMERSILE PUMP 65-70 TRACTOR
65 / PTO V 30-35 HP MONOBLOCK / SUMERSILE PUMP 70-90 TRACTOR
View Complete Details

Diesel Generators

  • Phase Single/Three
  • Frequency 50 Hz
  • ENGINE Cooling
  • Water /Air No. of Cyl.
  • One / Two Fuel
  • H.S. Diesel Speed
  • 1500 RPM SFC 1
  • gms/HP-Hr A. C. GENERATOR
  • Voltage 230/415 V
  • Regulation ± 5 % Max.
  • Insulation F Class
  • Mounting Foot

GOVERNINGA sensible mechnanical centrifugal type governer mounted on the camshaft gear. Speed variation is controlledwithin limits to comply with class B1 governing as per IS:10001 (GENERAL PURPOSE).

COOLINGEngine is continuously cooled by flow of water. Either by Radiator mounted on engine or direct water supply. Front radiator mounted engines also available.

STARTINGThe engine is designed for starting by hand. Electric Start Provision can also be provided against specific reauirement. Dynamo battery chargers also available

POLLUTION CONTROL DEVICESingle Element Catalytic Converter for control of NOx, CO, THC & HAPs.

SOUND & VIBRATION CONTROL DEVICEWe offer Canopy, Industrial type Air cleaner & Silencer, Round Duct Expansion Joints, Anti Vibration Mounts etc.

ENGINE SAFTY DEVICE (OPTIONAL)Engine controller with Manual Start/ Stop, Automatic shut down for fault, Keyswitch operation, 16A contacts for start/stop, Electronic warning lamp.

ENGINE SAFTY DEVICE CONTROLLER (OPTIONAL)Display of Battery Voltage, Oil Pressure, Temperature, Engine RPM & Running Hrs. , 14 Programmable parameters, Electronic alternator excitation circuit, 5 Digital & 4 Analog inputs, 3 relay outputs for start, Stop and one is programmable, Engine run hours counter, Automatic & manual operation mode, Remote Start & stop function. Sound Proofing canopy can also supplied.

MODEL KVA KW BHP RPM No. Of Piston Cooling Packing Size (cm) Nett. Wt. Kg. Gross Wt. Kg.
SINGLE PHASE   240 Volts 50 Hz            
MINI 2 2 4.5 1500 SINGLE Water/Air 90x50x100 125 170
V-2 4 4 6.5 1500 SINGLE Water/Air 112x65x130 325 475
V-3 5 5 8 1500 SINGLE Water/Air 112x65x130 330 485
V-4 6 6 10 1500 SINGLE Water/Air 112x65x130 360 510
V-5 7 7 11 1500 SINGLE Water/Air 112x65x135 370 520
V-6 8 8 14 1500 SINGLE Water 112x65x135 390 540
V-7 10 10 15 1500 DOUBLE Water/Air 120x70x160 445 64
V-8 12 12 20 1500 DOUBLE Water/Air 120x70x160 450 645
V-9 14 14 22 1500 DOUBLE Water/Air 120x70x160 460 655
V-10 16 16 18 1500 DOUBLE Water 125x85x165 470 665
V-10H 18 18 30 1500 DOUBLE Water 125x85x165 490 690
MODEL KVA KW BHP RPM No. Of Piston Cooling Packing Size (cm) Nett. Wt. Kg. Gross Wt. Kg.
THREE PHASE   415 Volts 4 pole 50 Hz          
V-11 6.25 5 8 1500 SINGLE Water/Air 112x65x130 340 490
V-12 7.5 6 10 1500 SINGLE Water/Air 112x65x130 365 515
V-13 8.75 7 11 1500 SINGLE Water/Air 112x65x135 380 530
V-14 10 8 14 1500 SINGLE Water 120x70x160 400 550
V-15 10 8 15 1500 DOUBLE Water/Air 120x70x160 450 640
V-16 12.5 10 15 1500 DOUBLE Water/Air 120x70x160 456 645
V-17 15 12 20 1500 DOUBLE Water/Air 120x70x160 485 670
V-18 17.5 14 22 1500 DOUBLE Water/Air 120x70x160 495 690
V-19 20 16 28 1500 DOUBLE Water 125x85x165 510 710
V-19H 22 18 30 1500 DOUBLE Water 125x85x165 130 740
View Complete Details

Welding Generator

Welding set that can be used on sites where there is no electricity

    • Alternating Current (AC)
    • Welding Rate: Normal :200 Amp., 250 Amp. & 400 Amp. .
    • Vidhata Diesel engine 10, 12 & 22 H.P
    • Engine cooling water or air cooled
    • Starting Electric start / Manual hand cranking.
    • Battery charging 12 Volt dynamo
    • Engine safety high engine temp or LOP uto shut off
    • Amp. meter
    • Max rod: 6 mm
    • Auxillary Output: 4kw 230v (with Circuit Breaker).
    • Alternator Semi Brushless.
    • With current controller remote.
    • AVAILABLE IN A.C. OR D.C Current
    • Open Type Frame & Canopy / Trailer type availabl.
    • Heavy-duty, field-provide design for long life.
    • Four way welding voltage regulator.
    • Low or high current usage switch.
    • Environmental protection for adverse conditions.
    • Short circuit protector 10 Amp. Fuse in control panel.
    • Diesel Engine Air or Water Cooling Optional.
    • 2000 Watt. 230 Volts External Output.
    • Hand Cranking as well as 12 Volt electric start optional.
    • Hand Cranking as well as 12 Volt electric start optional.
    • Battery charger 12 Volt Dynamo type or electronic(Optional).
    • A. C. Welding Current suitable to run 12/10/08 No Rod continuously and 06 no Rod when in need.
    • Rutile: An electrode for general use which is very flexible in use.
    • Cellulose: An electrode suitable for downward welding.
    • Basic: An electrode for top security technical assembly. This use is recommened for parts under significant mechanical strain. It requires welding under direct current (DC).
    • The maximum diameter of the welding rods is also an important criteria when selecting your Weldart set, do not forget to take this into account.

Auxillary Power:

    All Weldart welding sets are capable of producing current through their auxillary outlets. They can be used as standard electricity generating sets and the choice of model for this function is subject to the same criteria as the other electricity generating sets in the Vidhata Portable Power range.

Weldart Open Range Type: MODEL WL 250 / WL 400/ WL 600
Engine: Brand: Vidhata
Run Time: 7 hrs./ 15 hrs.
Tank: 10 Lit/ 20 Lit
Auxillary Source: 230v 2 Kw / 4 kw
   
Welding Rate:    
Normal 200 / 400 / 600 Amp.
Adjustments: Amp Min / Max 60 – 400 Amps
Current: AC / dc
Rods: ø Mini Maxi mm 1.6 – 5.2
Rutile Yes
All Types No
Maximum Starting Current: 55 V
Nominal: 25 V
EEC Noise Level:  
dB(A) @ 7m: 85
Dimensions L x W x H in cm: 112x65x130
Weight in Kg: 150/ 370 / 600
Options: Trolley Kit : Optional
Welding Kit optional
View Complete Details

AC Welding Sets Generators

AC Welding SetLeveraging on our long experience in the field, we produce a wide assortment of AC welding sets. These AC welding sets are made with supreme quality raw materials. Our range is demanded in pipe line welding, Road Construction etc and others. The specifications of the range are given below:

  • Type-Slipring and Semi brushless (rotating field)
  • Range 200 to 400 AMP
  • Dual function-Welding and Single phase light (2.0 KVA to 5.0 KVA)
  • Smooth welding control
  • Low diesel design

These welding genset are best available in economy range in India, which can help small and medium scale workshop owners do perform their daily routine work efficiently with out increasing the load of main line current, and these welding set technology perform very good in long cource of time with out any burning or parts requirements, These welding genset can easily cut metal from 2 or 3 mm ROD , its also called metal cutting machines which are portable and provision of taking high and low current output with regulator to select the current power, one 10 Amp. Fuse provided for sort circuit protection.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

Retailer of Generators from Agra, Uttar Pradesh by Basant Products India
Post Buy Requirement
BP

Basant Products India Agra, Uttar Pradesh

Agra, Uttar Pradesh, India
Verified Add Review

Generators #1123709

We are leaders in the market for providing best range of Mini Generator, dc generator, Tractor PTO shaft Operated Generator, Diesel Generators and Welding Generator

Mini Generator

  • Red Silver
  • Brand Name VIDHATA
We offer mini generator.- 3kva mini generator- diesel operated- fuel cons. 600gms per hour.- small size(portable)- no vibration- maintenance free- 1year warranty- export quality product- 100% genuine spare parts- made in india
View Complete Details

Dc Generator

  • Creator gensets from country AC GENSET
  • For N+1 redundancy, peak load demand, and site expansion, multiple DC generators can be operated at the same time and power outputs can be paralleled. It is impractical to parallel AC generators for these applications; therefore they must be over-sized for peak load demands and future expansion. Small loads can cause the engine to “wet stack”.
  • DC generator backs up both utility power and the rectifier bank. rectifier bank. AC generators back up only utility power. If the rectifier fails, the site is down.
  • Backing up power board reduces N+1 redundancy demand on the number of rectifier modules. This lowers the purchase and operational costs. N+1 redundancy of rectifier modules within a power board increases site capital and operating cost.
  • The battery charger or rectifier and the transfer switch for both prime power and solar hybrid applications can be eliminated. Fuel consumption is reduced, and reliability is greatly increased. Rectifiers, transfer switch and controls add considerably to the purchase, installation, and maintenance costs.
  • Variable engine speed option automatically adjusts to meet battery charging and load requirements, providing up to 40% savings in fuel. Engine speeds can vary without affecting voltage regulation. Engine must run at fixed speeds in order to maintain 60 or 50Hz frequency. Engine speed control provisions add to maintenance and reliability problems. Running engine without load shortens engine life.
  • Continuously running the DC generator during long power outages can be avoided in order to conserve fuel and reduce maintenance. The generator can charge the battery, then shut down and begin cycle again. The cumbersome design of an AC Generator/ transfer switch/rectifier system make frequent cycling undesirable.
  • With VIDHATA ’s high efficiency alternator we are able to use smaller horsepower engines, which produce lower acoustic noise. Smaller engines also facilitate installation permits on sites where the regulations are based on horsepower and noise. Combined with the rectifier power losses and the rectifier and air conditioning current surges during startup, the engines and alternators on the AC sets require over sizing. Engines are also oversized to assist in output frequency regulation.
  • A DC generator can “come on line faster than an AC generator. This allows a reduction in the size of the battery bank. Reducing the battery bank size lowers procurement and replacement costs. From experience, larger battery banks are required for AC generator backup systems.

Generator using its bush less / AVR Alternator technology in 2008. Since then numerous organizations have performed extensive testing on our generators VIDHATA assembles the genset to meet its clients requirements by adding the appropriate diesel engine to our DC alternators. The engines are available in either a liquid or air-cooled version. VIDHATA has designed this DC alternator incorporating state-of-the-art technologies and all new tooling to meet the increased performance demand for.

  • Low Maintenance
  • Low EMI Emissions
  • Very High Quality Electrical Output
  • Light Weight
  • Low Fuel Consumption
  • Low Acoustic Noise
  • High and Low Ambient Operation (-40 to 125 F)

VIDHATAPower has met these performance goals through an integrated engineering effort involving detailed analysis of engine, voltage regulator, field coil, magnet, stator, rotor systems output voltage and current.

SPECIFICATIONS

  • DC output 12 volts, 200 Amps
  • DC Voltage regulated at 1 Volt from no-load to full load
  • Dc Voltage will reduce drastically after the load current reaches its rated current & hence protecting generator & Engine from over load
  • Seperately Excited, Brushless, Provided with class H Insulation, Temp. rise limited to Class F. Suitable for an ambient temperature of 40C
  • D.C. Alternator for recharging battery banks. This is not an automotive style alternator because of their poor efficiency
  • 200 amps DC for recharging battery banks, DC generator is the most efficient and least cost solution
  • Require 5 h.p Prime mover at 1500 RPM ENGINE suitable to make a DC generator
  • We can supply complete DC generator close coupled or coupling type both with water cooled and air cooled engines

LOW MAINTENANCE AND HIGH RELIABILITY

  • The unique alternator design allows us to turn the engine at low speeds, thereby extending engine life.
  • The voltage regulator has automatic governing at high electrical load demands the regulator automatically increases engine RPM; at low loads the engine speed is automatically decreased.
  • VIDHATA Powers alternator has no: brushes, slip rings, There are no alternator parts to wear.
  • There are no electronic parts (diodes, etc.) nor electrical connections inside the alternator. There is nothing to short or vibrate loose inside the alternator.
  • The alternator is almost impossible to damage electrically. The outputs can be shorted for minutes without damage.
  • The output current is monitored by the voltage regulator through a current transducer. The voltage regulator has an adjustable current limit on the output. It is virtually impossible to overload the alternator.
  • VIDHATA Powers alternator should have an life of exceeding 50000 hours
  • The engine is protected against: over-temperature, low oil pressure, over-speed, (OPTIONAL).
  • The alternators rotor is dynamically balanced to improve the engines bearing life.

LOW FUEL CONSUMPTIONThe VIDHATA alternator has an efficiency of between 75 to 85% versus 55 to 70% for other DC alternators. Consume only 700 gm diesel in 1 hr.

HIGH AND LOW AMBIENT OPERATION

  • During starting the regulator keeps the field current off. This feature coupled with the small light weight rotor provides a minimal load on the starter motor.
  • For low ambient temperatures (-40 to 10 F) cold starting aids are available.
  • The higher alternator efficiency allows the engine to run cooler in high ambient temperatures. The increased alternator efficiency reduces the mechanical load on the engine which then reduces the engines cooling requirement.
OPTIONS

ENGINE STYLES

  • Diesel Engine: either air-cooled or water-cooled.

VIDHATA DC GENERATORS ARE MORE EXPENSIVE TO PURCHASE THAN AC GENERATORS BECAUSE

  • Our alternators uses a high frequency design (360Hz) that reduces weight, size, and greatly improves the quality of electrical power. The high frequency design requires more labor to wind the stator. Typical AC generators are only 50 or 60 Hz.
  • The stator has a 6-phase design to also improve electrical quality and the torque ripple on the engine for better fuel economy. The 6-phase design requires more labor to wind the stator. Standard AC generators are only single or three phase.
  • The VIDHATAs DC generator set is optimized to produce a high current, low voltage power output for charging batteries and powering DC loads directly. The AC generator is optimized for a high voltage, low current output and requires an external power supply or battery charger to convert AC into DC. The low voltage, heavy current windings are more expensive to wind.
  • VIDHATAs DC generator is very corrosion resistant. We make extensive use of stainless steel fasteners and coated aluminum materials. Certain components must be constructed of steel due the magnetic properties; here we coat with high temperature coatings and/or Cadmium (CAD) plating. Corrosion resistance is important for installations in marine or humid environments or exposed to agricultural and garden chemicals. This construction is not typical of AC generators.
  • VIDHATA uses the very best magnetic wire in an HML grade for a class H rating. This facilitates long life in warm or dusty climates.

Why use DC Generators for Telecommunications, Solar, UPS, Backup, Prime Power.There is not a single universal reason why all applications should choose a DC generator over an AC generator. There are, however, specific reasons for each project or a combination of reasons that favor the DC generator. Some of which include.

APPLICATIONS IN GENERAL (INCLUDING SOLAR/WIND HYBRID, PRIME POWER, AND BACKUP)

  • The DC generator system is designed and optimized to deliver the high currents at low voltages required for battery charging and operating DC loads. No battery chargers or power supplies are required.
  • DC generators do not require a transfer switch. Transfer switches lower system reliability.
  • In prime power applications the DC generator lowers the overall cost of the system.
  • Certain AC generators and switch mode power supplies are incompatible. These AC generators have voltage regulators that cannot regulate voltage due to the current pulsing load of the switch mode power supplies. VIDHATA DC generators when connected to a battery do not suffer this incompatibility.
  • DC generators are more fuel-efficient. Site operators want the longest run time with the least amount of fuel on site.
  • VIDHATAs DC generators are simpler in design, have considerably less maintenance and are more reliable than AC generators. Propane carburetion and electronic speed governors require frequent calibration and testing. If the propane carburetion, ignition system, or governor speed control should develop a problem, alternator voltage regulation and frequency control will fail. Some equipment powered by the generator will be damaged, other equipment may survive. How many of your AC loads can tolerate a wide swing in frequency?.
  • VIDHATAs DC generators have a current limit control to prevent the alternator from overheating and the engine from stalling during shorts or overloads. This feature is extremely important in battery charging because a battery in a low state of charge can demand more power than the generator or battery charger can manage. VIDHATAs DC generators will continues to supply power under current limit control, allowing the battery to increase its charge and drop its current demand. The AC generator uses a fuse or circuit breaker to protect against shorts and over current so the battery fails to get charged if it is overly discharged. The additional problem is that for remote sites a person is required to visit the site to replace or reset the fuse or circuit breaker and devise a means where the batteries can be brought to a state of charge where the batteries can take over.
  • VIDHATA DC generators can be connected in parallel and load share. Paralleling these small AC generators is not practical. In many projects there are concerns about future site expansion and given load estimates are sometimes understated.
  • Maintainability. DC generators use smaller engines that can be lifted by hand and transported to a shop for repair. The high-level generator mechanics are not required, or their expensive travel time to the site.
  • AC generators are typically oversized to handle starting currents of motors and to provide light enough engine loads to facilitate speed regulation. Engines that are lightly loaded build up carbon around the valves and exhaust lines (wet stacking) this creates additional engine maintenance.
  • DC generators are considerably smaller in size and use smaller horsepower engines. This facilitates both roof mount installations and installations inside the small shelters, as well as the required permit process.
  • DC generator lowers the costs to install and operate. It is smaller in size and requires less site support. Transport to the site and installation is facilitated because: smaller shelter and concrete pads can be used, elevator transport to roof rather than crane, smaller helicopters or vehicles for transport. Fuel consumption is lower, so cost to transport fuel to the site is lower (transportation of the fuel to the site can be very expensive).
  • Engines need a warm up period before they are able to provide full power, for an AC generator this translates to providing a stable frequency and voltage. VIDHATA s DC generator can deliver power at a reduced level immediately after starting, then switch to full power after warn up. Also a cold engine can exhibit speed fluctuations, which has no effect on VIDHATA s DC generators.

UPS SYSTEMS

  • VIDHATA s DC generators connect direct to the battery bank so there are fewer problems with on site permitting. Many inspectors and utilities are concerned with isolation of the AC generator from the utility grid. Using a DC generator there should be no questions on isolation from the inspectors.
  • VIDHATA s DC generator can provide regulated charging to the battery and is unaffected by the pulse currents of the switch mode inverter.
View Complete Details

Tractor PTO Shaft Operated Generator

Tractor PTO shaft Operated Generator for driving submersible pumps for IrrigationVIDHATA range of Tractor Operated Generators is available in rotating field. These Tractor Operated Generators are self-excited and self-regulated in semi-brushless and compounding system. Made from the finest quality rolled steel with welded feet and heavy duty cast iron construction, the electric performance gives a voltage regulation and adjustment within a range of 5% plus/minus. Our generators are rated for single or three phase operations apart from customized requirements offered. Backed by team of adroit professionals, we are offering a qualitative range of Tractor Driven Generator Set that are best for operating farm electric motors where electric power is not available or voltage are too low or only few weeks using of pumps where electric grid power is expensive, It is fabricated as per the latest technological quality approved raw materials under the supervision of our skilled technocrats. Vidhata manufacture and exporter of Tractor Driven Generator Set in various sizes & designs and can also be custom designed as per the clients demands.

OPTIONAL CONTROL PANEL AND PTO SHAFT ARE PROVIDED WITH PRODUCT

  • We supply various size of belts and pulley and PTO SHAFT to suit various tractors RPM 540 , 750, 1000,
  • COMPACTABLE TRACTORS FOR VIDHATA PTO OPERATED TRACTOR GENERATORS / GENSET
  • Landani, Angad Tractors, Balwan Tractors, Eicher, Escorts, Farmer Tractor, HMT Tractors, Indo Farm, John Deere
  • Mahindra, New Holland Fiat India, Sonalika , Standard, TAFE

KVA (MODEL) SUITABLE FOR PUMP HP REQUIRED PRIME MOVER
10  / PTO V 5 -7.5 HP MONOBLOCK / SUMERSIBLE PUMP 15 TRACTOR PTO
15 /  PTO V 10 HP MONOBLOCK / SUMERSIBLE PUMP 20 TRACTOR PTO
20 / PTO V 10-12.5 HP MONOBLOCK / SUMERSIBLE PUMP 25- 35 TRACTOR PTO
25 / PTO V 12.5 – 15 MONOBLOCK / SUMERSIBLE PUMP 35 TRACTOR PTO
30 / PTO V 12.5 -17  HP MONOBLOCK / SUMERSILE PUMP 35 -41 TRACTOR PTO
35 / PTO MAXO 12.5 -20 HP MONOBLOCK / SUMERSILE PUMP 35 TO 50 TRACTOR PTO
40 / PTO V 20   HP MONOBLOCK / SUMERSILE PUMP 50 -60 TRACTOR
50 / PTO V 20-25  HP MONOBLOCK / SUMERSILE PUMP 65-70 TRACTOR
65 / PTO V 30-35 HP MONOBLOCK / SUMERSILE PUMP 70-90 TRACTOR
View Complete Details

Diesel Generators

  • Phase Single/Three
  • Frequency 50 Hz
  • ENGINE Cooling
  • Water /Air No. of Cyl.
  • One / Two Fuel
  • H.S. Diesel Speed
  • 1500 RPM SFC 1
  • gms/HP-Hr A. C. GENERATOR
  • Voltage 230/415 V
  • Regulation ± 5 % Max.
  • Insulation F Class
  • Mounting Foot

GOVERNINGA sensible mechnanical centrifugal type governer mounted on the camshaft gear. Speed variation is controlledwithin limits to comply with class B1 governing as per IS:10001 (GENERAL PURPOSE).

COOLINGEngine is continuously cooled by flow of water. Either by Radiator mounted on engine or direct water supply. Front radiator mounted engines also available.

STARTINGThe engine is designed for starting by hand. Electric Start Provision can also be provided against specific reauirement. Dynamo battery chargers also available

POLLUTION CONTROL DEVICESingle Element Catalytic Converter for control of NOx, CO, THC & HAPs.

SOUND & VIBRATION CONTROL DEVICEWe offer Canopy, Industrial type Air cleaner & Silencer, Round Duct Expansion Joints, Anti Vibration Mounts etc.

ENGINE SAFTY DEVICE (OPTIONAL)Engine controller with Manual Start/ Stop, Automatic shut down for fault, Keyswitch operation, 16A contacts for start/stop, Electronic warning lamp.

ENGINE SAFTY DEVICE CONTROLLER (OPTIONAL)Display of Battery Voltage, Oil Pressure, Temperature, Engine RPM & Running Hrs. , 14 Programmable parameters, Electronic alternator excitation circuit, 5 Digital & 4 Analog inputs, 3 relay outputs for start, Stop and one is programmable, Engine run hours counter, Automatic & manual operation mode, Remote Start & stop function. Sound Proofing canopy can also supplied.

MODEL KVA KW BHP RPM No. Of Piston Cooling Packing Size (cm) Nett. Wt. Kg. Gross Wt. Kg.
SINGLE PHASE   240 Volts 50 Hz            
MINI 2 2 4.5 1500 SINGLE Water/Air 90x50x100 125 170
V-2 4 4 6.5 1500 SINGLE Water/Air 112x65x130 325 475
V-3 5 5 8 1500 SINGLE Water/Air 112x65x130 330 485
V-4 6 6 10 1500 SINGLE Water/Air 112x65x130 360 510
V-5 7 7 11 1500 SINGLE Water/Air 112x65x135 370 520
V-6 8 8 14 1500 SINGLE Water 112x65x135 390 540
V-7 10 10 15 1500 DOUBLE Water/Air 120x70x160 445 64
V-8 12 12 20 1500 DOUBLE Water/Air 120x70x160 450 645
V-9 14 14 22 1500 DOUBLE Water/Air 120x70x160 460 655
V-10 16 16 18 1500 DOUBLE Water 125x85x165 470 665
V-10H 18 18 30 1500 DOUBLE Water 125x85x165 490 690
MODEL KVA KW BHP RPM No. Of Piston Cooling Packing Size (cm) Nett. Wt. Kg. Gross Wt. Kg.
THREE PHASE   415 Volts 4 pole 50 Hz          
V-11 6.25 5 8 1500 SINGLE Water/Air 112x65x130 340 490
V-12 7.5 6 10 1500 SINGLE Water/Air 112x65x130 365 515
V-13 8.75 7 11 1500 SINGLE Water/Air 112x65x135 380 530
V-14 10 8 14 1500 SINGLE Water 120x70x160 400 550
V-15 10 8 15 1500 DOUBLE Water/Air 120x70x160 450 640
V-16 12.5 10 15 1500 DOUBLE Water/Air 120x70x160 456 645
V-17 15 12 20 1500 DOUBLE Water/Air 120x70x160 485 670
V-18 17.5 14 22 1500 DOUBLE Water/Air 120x70x160 495 690
V-19 20 16 28 1500 DOUBLE Water 125x85x165 510 710
V-19H 22 18 30 1500 DOUBLE Water 125x85x165 130 740
View Complete Details

Welding Generator

Welding set that can be used on sites where there is no electricity

    • Alternating Current (AC)
    • Welding Rate: Normal :200 Amp., 250 Amp. & 400 Amp. .
    • Vidhata Diesel engine 10, 12 & 22 H.P
    • Engine cooling water or air cooled
    • Starting Electric start / Manual hand cranking.
    • Battery charging 12 Volt dynamo
    • Engine safety high engine temp or LOP uto shut off
    • Amp. meter
    • Max rod: 6 mm
    • Auxillary Output: 4kw 230v (with Circuit Breaker).
    • Alternator Semi Brushless.
    • With current controller remote.
    • AVAILABLE IN A.C. OR D.C Current
    • Open Type Frame & Canopy / Trailer type availabl.
    • Heavy-duty, field-provide design for long life.
    • Four way welding voltage regulator.
    • Low or high current usage switch.
    • Environmental protection for adverse conditions.
    • Short circuit protector 10 Amp. Fuse in control panel.
    • Diesel Engine Air or Water Cooling Optional.
    • 2000 Watt. 230 Volts External Output.
    • Hand Cranking as well as 12 Volt electric start optional.
    • Hand Cranking as well as 12 Volt electric start optional.
    • Battery charger 12 Volt Dynamo type or electronic(Optional).
    • A. C. Welding Current suitable to run 12/10/08 No Rod continuously and 06 no Rod when in need.
    • Rutile: An electrode for general use which is very flexible in use.
    • Cellulose: An electrode suitable for downward welding.
    • Basic: An electrode for top security technical assembly. This use is recommened for parts under significant mechanical strain. It requires welding under direct current (DC).
    • The maximum diameter of the welding rods is also an important criteria when selecting your Weldart set, do not forget to take this into account.

Auxillary Power:

    All Weldart welding sets are capable of producing current through their auxillary outlets. They can be used as standard electricity generating sets and the choice of model for this function is subject to the same criteria as the other electricity generating sets in the Vidhata Portable Power range.

Weldart Open Range Type: MODEL WL 250 / WL 400/ WL 600
Engine: Brand: Vidhata
Run Time: 7 hrs./ 15 hrs.
Tank: 10 Lit/ 20 Lit
Auxillary Source: 230v 2 Kw / 4 kw
   
Welding Rate:    
Normal 200 / 400 / 600 Amp.
Adjustments: Amp Min / Max 60 – 400 Amps
Current: AC / dc
Rods: ø Mini Maxi mm 1.6 – 5.2
Rutile Yes
All Types No
Maximum Starting Current: 55 V
Nominal: 25 V
EEC Noise Level:  
dB(A) @ 7m: 85
Dimensions L x W x H in cm: 112x65x130
Weight in Kg: 150/ 370 / 600
Options: Trolley Kit : Optional
Welding Kit optional
View Complete Details

AC Welding Sets Generators

AC Welding SetLeveraging on our long experience in the field, we produce a wide assortment of AC welding sets. These AC welding sets are made with supreme quality raw materials. Our range is demanded in pipe line welding, Road Construction etc and others. The specifications of the range are given below:

  • Type-Slipring and Semi brushless (rotating field)
  • Range 200 to 400 AMP
  • Dual function-Welding and Single phase light (2.0 KVA to 5.0 KVA)
  • Smooth welding control
  • Low diesel design

These welding genset are best available in economy range in India, which can help small and medium scale workshop owners do perform their daily routine work efficiently with out increasing the load of main line current, and these welding set technology perform very good in long cource of time with out any burning or parts requirements, These welding genset can easily cut metal from 2 or 3 mm ROD , its also called metal cutting machines which are portable and provision of taking high and low current output with regulator to select the current power, one 10 Amp. Fuse provided for sort circuit protection.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us