Post Buy Requirement

Measuring Instruments & Equipment

Our offered Product range includes Standard Penetrometer, Rapid Moisture Meter, Sokkia CX Series and Sand Pouring Cylinder.

Standard Penetrometer

Used to determine grade of bitumen. The penetration tests determine consistency of bitumen for the purpose of grading. Depth in units 1/10 of millimeter to which a standard needle having a standard weight will penetrate vertically in a duration of five seconds at a temperature of 25ºC determines penetration for gradation.

 

Salient Features:

  • Specifications: It consists of a vertical pillar mounted on a base provided with leveling screws. The head, together with dial plunger rod and cone (or needle) slides on a pillar and can be clamped at any desired height. A rack & pinion and pointer assemble provides fine adjustment of needle or cone tip to sample. It incorporates a clutch mechanism which makes reading of penetration and subsequent resetting a simple and accurate operation. The dial is graduated in 400 1/10 and the millimeter sub-divisions and the needle pointer against figures makes easy reading. Supplied with bitumen penetration needle, ring weight one each 50 gms, and two sample container.
  • Accessories: Penetration cone for empirical estimation of penetration of lubricating grease, petroleum jelly etc.

 

Automatic Standard Penetrometer: Same as above but supplied with transistorized timer and Electro magnet incorporated in the clutch mechanism to accurately control penetration time to exact five seconds.

View Complete Details

Rapid Moisture Meter

Features:

We provide highly efficient rapid moisture meter which is basically used for quick determination of moisture percentage of materials in powder form like Soil.

Calcium carbide when comes in contact with moisture acetylene gas in generate. This principle is used in rapid moisture meter. A weighted quantity of sample is mixed with fixed quantity of calcium carbide reagent and the whole mixture is thoroughly shaken in a vessel to which a pressure gauge is fixed. The acetylene gas produced developes pressure and pressure gauge is calibrated to read percentage moisture. The instrument indicates moisture on wet/weight basis easily convertible to dry weight basis.

 

The apparatus is offered in polished wooden carrying case and includes:

  • Pressure vessel with clamp for sealing

 

Rubber sealing gasket:

  • Pressure gauge in moisture content 0-25% or 0-50% on wet weight basis
  • A counter poised balance to weigh the sample
  • A scoop for measuring carbide reagent
  • One cleaning brush
  • Set of 4 steel balls and one bottle of calcium carbide (500 gm)
View Complete Details

Sokkia CX Series

Advanced Angle Measurement System:

  • CX features SOKKIA's original absolute encoders that provide long-term reliability in any job site condition. Dual-axis compensator ensures stable measurements even when setup on uneven terrain.
  • Sokkia’s traditional motion clamp and tangent screw are employed to ensure stable angle measurement.
  • CX101 and CX102 feature groundbreaking IACS (Independent Angle Calibration System) technology for extremely reliable angle measurement.

 

The Longest*1 Battery Life 36 Hours!

  • The CX single battery can last up to 36 hours.
  • Greatly reduces likelihood of low power during any full-days work.
  • Eliminates the need for nightly recharging or carrying extra batteries.

 

Waterproof, Rugged, and Operator Friendly:

  • IP66 dustproof / waterproof rating.
  • Metal chassis and heavy duty handle add ruggedness.
  • Standard usage temperature range -20° to +50°C. Low temperature models can be used as low as -30° and high temperature models up to +60°C.
  • Low and High temperature models available as options.

Specification

Model CX-101 CX-102 CX-103 CX-105 CX-107
Telescope
Magnification / Resolving power 30x / 2.5" 30x / 3.5"
Others Length: 171mm (6.7in.), Objective aperture: 45mm (1.8in.) (48mm (1.9in.) for EDM), Image: Erect,
Field of view: 1°30' (26m/1,000m),Minimum focus: 1.3m (4.3ft.), Reticle illumination: 5 brightness levels
Angle measurement
Display resolution 0.5" / 1"
(0.0001 / 0.0002gon, 0.002 / 0.005mil)
1" / 5"
(0.0002 / 0.001gon, 0.005 / 0.02mil)
Accuracy (ISO 17123-3:2001) 1" 2" 3" 5" 7"
IACS (Independent Angle Calibration System) Provided -
Dual-axis compensator / Collimation compensation Dual-axis liquid tilt sensor, working range: ±6' (±111mgon) / Collimation compensation available
Distance measurement
Laser output *1 Reflectorless mode: Class 3R / Prism / sheet mode: Class 1
Measuring range Reflectorless*3 0.3 to 500m(1.0 to 1,640ft.)
(under average conditions*2) Reflective sheet*4/*5 RS90N-K: 1.3 to 500m (4.3 to 1,640ft.)
RS50N-K: 1.3 to 300m (4.3 to 980ft.), RS10N-K: 1.3 to 100m (4.3 to 320ft.)
Mini prisms CP01: 1.3 to 2,500m (8,200ft.), OR1PA: 1.3 to 500m (1,640ft.)
One AP prism 1.3 to 4,000m (4.3 to 13,120ft.) / Under good conditions*6: 5,000m (16,400ft.)
Three AP prisms to 5,000m (16,400ft.) / Under good conditions*6: to 6,000m (19,680ft.)
Display resolution Fine/Rapid: 0.001m / 0.01ft. / 1/8in. Tracking: 0.01m / 0.1ft. / 1/2in.
Accuracy*2
(ISO 17123-4:2001)
(D=measuring distance in mm)
Reflectorless*3 (3 + 2ppm x D) mm*7
Reflective sheet*4 (3 + 2ppm x D) mm
AP/CP prism (2 + 2ppm x D) mm
Measuring time*8 Fine: 0.9s (initial 1.7s), Rapid: 0.7s (initial 1.4s), Tracking: 0.3s (initial 1.4s)
Interface and Data management
Display / Keyboard Graphic LCD, 192 x 80 dots, backlight, contrast adjustment / Alphanumeric keyboard / 25 keys with backlight
Control panel location*9 On both faces On one face
Trigger key On right instrument support
Data storage Internal memory Approx. 10,000 points
Plug-in memory device USB flash memory (max. 8GB)
Interface Serial RS-232C, USB2.0 (Type A, for USB flash memory)
Bluetooth modem (option)*10 Bluetooth Class 1, Ver.2.1+EDR, Operating range: up to 300m (980ft.)*11
General
Laser-pointer*12 Coaxial red laser using EDM beam
Guide light*12 Green LED (524nm) and Red LED (626nm), Operating range: 1.3 to 150m (4.3 to 490ft.)
Levels Graphic 6’ (Inner Circle)
Circular level 10' / 2mm
Optical plummet Magnification: 3x, Minimum focus: 0.3m (11.8in.) from tribrach bottom
Laser plummet (option) Red laser diode (635nm±10nm), Beam accuracy: <=HYPERLINK "mailto:%3D1.0mm@1.3m"1.0mm@1.3m, Class 2 laser product
Dust and water protection IP66 (IEC 60529:2001)
Operating temperature*13 -20 to +50ºC (-4 to +122ºF)
Size with handle*8 Control panel on both faces: W191 x D181 x H348mm (W7.5 x D7.1 x H13.7in.)
Control panel on one face: W191 x D174 x H348mm (W7.5 x D6.9 x H13.7in.)
Weight with handle and battery Approx. 5.6kg (12.3 lb.)
Power supply
Battery BDC70 detachable battery Li-ion rechargeable battery
Operating time (20ºC) BDC70 Approx. 36 hours (single distance measurement every 30 seconds)
External battery (option) BDC60: approx. 44 hours, BDC61: approx. 89 hours
(single distance measurement every 30 seconds)








View Complete Details

Sand Pouring Cylinder

  • Body Material Steel

Sand Replacement Method: Three Sizes Available.

  • 10cm (Small Size)
  • 15cm (Medium Size)
  • 20cm (Large Size)

 

10cm (Small Size):- Sand Replacement Method. Consists Of Sand Pouring Cylinder, One Calibrating Container 10 Cm Dia & A Square Tray Of 30 Cm X 30 Cm With A Central Hole Of 10 Cm Diameter. Relevant Standard : Is : 2720(Part-xxviii)

 

15cm (Medium Size):- Sand Replacement Method. Consisting Of Sand Pouring Cylinder Container Metal Tray Hole In The Centre.

 

20cm (Large Size):- Sand Replacement Method. With Calibrating Container Of 250mm Internal Depth, One Metal Tray 450 Mm Square And 50 Mm Deep With A 200 Mm Dia Hole In The Centre.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

Retailer of Measuring Instruments & Equipment from Vadodara, Gujarat by Bansal And Company
Post Buy Requirement

Measuring Instruments & Equipment

Our offered Product range includes Standard Penetrometer, Rapid Moisture Meter, Sokkia CX Series and Sand Pouring Cylinder.

Standard Penetrometer

Used to determine grade of bitumen. The penetration tests determine consistency of bitumen for the purpose of grading. Depth in units 1/10 of millimeter to which a standard needle having a standard weight will penetrate vertically in a duration of five seconds at a temperature of 25ºC determines penetration for gradation.

 

Salient Features:

  • Specifications: It consists of a vertical pillar mounted on a base provided with leveling screws. The head, together with dial plunger rod and cone (or needle) slides on a pillar and can be clamped at any desired height. A rack & pinion and pointer assemble provides fine adjustment of needle or cone tip to sample. It incorporates a clutch mechanism which makes reading of penetration and subsequent resetting a simple and accurate operation. The dial is graduated in 400 1/10 and the millimeter sub-divisions and the needle pointer against figures makes easy reading. Supplied with bitumen penetration needle, ring weight one each 50 gms, and two sample container.
  • Accessories: Penetration cone for empirical estimation of penetration of lubricating grease, petroleum jelly etc.

 

Automatic Standard Penetrometer: Same as above but supplied with transistorized timer and Electro magnet incorporated in the clutch mechanism to accurately control penetration time to exact five seconds.

View Complete Details

Rapid Moisture Meter

Features:

We provide highly efficient rapid moisture meter which is basically used for quick determination of moisture percentage of materials in powder form like Soil.

Calcium carbide when comes in contact with moisture acetylene gas in generate. This principle is used in rapid moisture meter. A weighted quantity of sample is mixed with fixed quantity of calcium carbide reagent and the whole mixture is thoroughly shaken in a vessel to which a pressure gauge is fixed. The acetylene gas produced developes pressure and pressure gauge is calibrated to read percentage moisture. The instrument indicates moisture on wet/weight basis easily convertible to dry weight basis.

 

The apparatus is offered in polished wooden carrying case and includes:

  • Pressure vessel with clamp for sealing

 

Rubber sealing gasket:

  • Pressure gauge in moisture content 0-25% or 0-50% on wet weight basis
  • A counter poised balance to weigh the sample
  • A scoop for measuring carbide reagent
  • One cleaning brush
  • Set of 4 steel balls and one bottle of calcium carbide (500 gm)
View Complete Details

Sokkia CX Series

Advanced Angle Measurement System:

  • CX features SOKKIA's original absolute encoders that provide long-term reliability in any job site condition. Dual-axis compensator ensures stable measurements even when setup on uneven terrain.
  • Sokkia’s traditional motion clamp and tangent screw are employed to ensure stable angle measurement.
  • CX101 and CX102 feature groundbreaking IACS (Independent Angle Calibration System) technology for extremely reliable angle measurement.

 

The Longest*1 Battery Life 36 Hours!

  • The CX single battery can last up to 36 hours.
  • Greatly reduces likelihood of low power during any full-days work.
  • Eliminates the need for nightly recharging or carrying extra batteries.

 

Waterproof, Rugged, and Operator Friendly:

  • IP66 dustproof / waterproof rating.
  • Metal chassis and heavy duty handle add ruggedness.
  • Standard usage temperature range -20° to +50°C. Low temperature models can be used as low as -30° and high temperature models up to +60°C.
  • Low and High temperature models available as options.

Specification

Model CX-101 CX-102 CX-103 CX-105 CX-107
Telescope
Magnification / Resolving power 30x / 2.5" 30x / 3.5"
Others Length: 171mm (6.7in.), Objective aperture: 45mm (1.8in.) (48mm (1.9in.) for EDM), Image: Erect,
Field of view: 1°30' (26m/1,000m),Minimum focus: 1.3m (4.3ft.), Reticle illumination: 5 brightness levels
Angle measurement
Display resolution 0.5" / 1"
(0.0001 / 0.0002gon, 0.002 / 0.005mil)
1" / 5"
(0.0002 / 0.001gon, 0.005 / 0.02mil)
Accuracy (ISO 17123-3:2001) 1" 2" 3" 5" 7"
IACS (Independent Angle Calibration System) Provided -
Dual-axis compensator / Collimation compensation Dual-axis liquid tilt sensor, working range: ±6' (±111mgon) / Collimation compensation available
Distance measurement
Laser output *1 Reflectorless mode: Class 3R / Prism / sheet mode: Class 1
Measuring range Reflectorless*3 0.3 to 500m(1.0 to 1,640ft.)
(under average conditions*2) Reflective sheet*4/*5 RS90N-K: 1.3 to 500m (4.3 to 1,640ft.)
RS50N-K: 1.3 to 300m (4.3 to 980ft.), RS10N-K: 1.3 to 100m (4.3 to 320ft.)
Mini prisms CP01: 1.3 to 2,500m (8,200ft.), OR1PA: 1.3 to 500m (1,640ft.)
One AP prism 1.3 to 4,000m (4.3 to 13,120ft.) / Under good conditions*6: 5,000m (16,400ft.)
Three AP prisms to 5,000m (16,400ft.) / Under good conditions*6: to 6,000m (19,680ft.)
Display resolution Fine/Rapid: 0.001m / 0.01ft. / 1/8in. Tracking: 0.01m / 0.1ft. / 1/2in.
Accuracy*2
(ISO 17123-4:2001)
(D=measuring distance in mm)
Reflectorless*3 (3 + 2ppm x D) mm*7
Reflective sheet*4 (3 + 2ppm x D) mm
AP/CP prism (2 + 2ppm x D) mm
Measuring time*8 Fine: 0.9s (initial 1.7s), Rapid: 0.7s (initial 1.4s), Tracking: 0.3s (initial 1.4s)
Interface and Data management
Display / Keyboard Graphic LCD, 192 x 80 dots, backlight, contrast adjustment / Alphanumeric keyboard / 25 keys with backlight
Control panel location*9 On both faces On one face
Trigger key On right instrument support
Data storage Internal memory Approx. 10,000 points
Plug-in memory device USB flash memory (max. 8GB)
Interface Serial RS-232C, USB2.0 (Type A, for USB flash memory)
Bluetooth modem (option)*10 Bluetooth Class 1, Ver.2.1+EDR, Operating range: up to 300m (980ft.)*11
General
Laser-pointer*12 Coaxial red laser using EDM beam
Guide light*12 Green LED (524nm) and Red LED (626nm), Operating range: 1.3 to 150m (4.3 to 490ft.)
Levels Graphic 6’ (Inner Circle)
Circular level 10' / 2mm
Optical plummet Magnification: 3x, Minimum focus: 0.3m (11.8in.) from tribrach bottom
Laser plummet (option) Red laser diode (635nm±10nm), Beam accuracy: <=HYPERLINK "mailto:%3D1.0mm@1.3m"1.0mm@1.3m, Class 2 laser product
Dust and water protection IP66 (IEC 60529:2001)
Operating temperature*13 -20 to +50ºC (-4 to +122ºF)
Size with handle*8 Control panel on both faces: W191 x D181 x H348mm (W7.5 x D7.1 x H13.7in.)
Control panel on one face: W191 x D174 x H348mm (W7.5 x D6.9 x H13.7in.)
Weight with handle and battery Approx. 5.6kg (12.3 lb.)
Power supply
Battery BDC70 detachable battery Li-ion rechargeable battery
Operating time (20ºC) BDC70 Approx. 36 hours (single distance measurement every 30 seconds)
External battery (option) BDC60: approx. 44 hours, BDC61: approx. 89 hours
(single distance measurement every 30 seconds)








View Complete Details

Sand Pouring Cylinder

  • Body Material Steel

Sand Replacement Method: Three Sizes Available.

  • 10cm (Small Size)
  • 15cm (Medium Size)
  • 20cm (Large Size)

 

10cm (Small Size):- Sand Replacement Method. Consists Of Sand Pouring Cylinder, One Calibrating Container 10 Cm Dia & A Square Tray Of 30 Cm X 30 Cm With A Central Hole Of 10 Cm Diameter. Relevant Standard : Is : 2720(Part-xxviii)

 

15cm (Medium Size):- Sand Replacement Method. Consisting Of Sand Pouring Cylinder Container Metal Tray Hole In The Centre.

 

20cm (Large Size):- Sand Replacement Method. With Calibrating Container Of 250mm Internal Depth, One Metal Tray 450 Mm Square And 50 Mm Deep With A 200 Mm Dia Hole In The Centre.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us