Single Core Insulated Copper Conductor (Unsheathed) - 01

Single Core Insulated Copper Conductor(Unsheathed)Flexible Cables 1100 Voltage Grade For Industrial Application

Basic Code Nominal Cross Sectional area of conductor Number/Nom. Dia of cond. strands* Thickness of Insulation (Nom) Approx. Overall Diameter Conduit/Trunking Unenclosed clipped directly to a surface or on cable trays Max. Conductor Resistance per KM at 200C
Life Line (FR) Sq. mm. mm mm mm Amps Amps Ohms
WHFFDN--B1010 10 80/0.4 1.0 6.30 50 61 1.91
WHFFDN--B1016 16 126/0.4 1.0 7.40 68 82 1.21
WHFFDN--B1025 25 196/0.4 1.2 9.10 85 103 0.780
WHFFDN--B1035 35 276/0.4 1.2 10.30 108 132 0.554
WHFFDN--B1050 50 396/0.4 1.4 12.20 144 174 0.386
Note : Conductor as per class V. 100 meter packing lengths as per IS:694 & in bigger packing on request.

The number and diameter of conductor strands are for reference only. Conductor resistance as per IS:8130 is the governing criteria.

Construction :-
Conductor : Plain annealed copper conductor as per IS:8130
Insulation
Primary - Natural Type A PVC.
Secondary - Skin colour coated PVC.(25 sq. mm & above are provided with unicolour Insulation only)
Colour : Red, Yellow, Blue, Black & Green








View Complete Details

Single Core Insulated Copper Conductor (Unsheathed) - 02

Single Core Insulated Copper Conductor (Unsheathed)Cable For Fixed Wiring 1100 Voltage Grade

Basic Code Nominal Cross Sectional area of conductor Stranding No./Nom Dia of Cond. Thickness of Insulation (Nom) Stands* Approx. Overall Diameter Conduit/Trunking Unenclosed clipped directly to a surface or on cable trays Max. Conductor Resistance per K.M. at 200C Amps
Sq. MM MM MM MM Amps Amps Ohms
WHFMDNA11X0 1.0 7/0.43 0.7 2.8 13 14 18.10
WHFMDNA11X5 1.5 7/0.52 0.7 3.1 16 19 12.10
WHFMDNA12X5 2.5 7/0.67 0.8 3.8 22 26 7.41
WHFMDNA14X0 4.0 7/0.85 0.8 4.30 29 35 4.61
WHFMDNA16X0 6.0 7/1.04 0.8 4.90 37 49 3.08
WHFMDNA1010 10 7/1.35 1.0 6.30 50 66 1.83
WHFMDNA1016 16 7/1.70 1.0 7.40 68 89 1.15
WHFMDNA1025 25 7/1.70 1.2 9.10 85 116 0.727
WHFMDNA1035 35 7/2.50 1.2 10.30 109 143 0.524
WHFMDNA1050 50 19/1.78 1.4 12.20 144 174 0.387
Note : 1-6 sq.mm in 90 mtrs. and 10-50 sq.mm. in 100 mtrs & in bigger packing on request Generally as per IS:694. Manufactured against customer's orders only for economical runs.

The number and diameter of conductor strands are for reference only. Conductor resistance as per IS:8130 is the governing criteria.

Construction
Conductor :
Plain annealed copper conductor as per IS:8130
Insulation : Primary - Natural PVC Type A PVC
Secondary - Skin colour coated PVC.
Colour : Red/Yellow/Blue/Black/Green
(25 sq. mm & above are provided with unicolour Insulation only)








View Complete Details

Multicore Round Insulated Copper Conductor And Sheathed

Multicore Round Insulated Copper Conductor And Sheathed Black Flexible Cables 1100 Voltage Grade

Basic Code Nominal Cross Sectional area of conductor MM Number Nom. Dia of cond. strands MM Thickness of Insulation (Nom) MM Sheath Two Core MM Sheath Three Core MM Sheath Four Core MM Diameter Two Core MM Diameter Three Core MM Diameter Four Core MM Current Rating AC Amps DC or Single Phase AC 3 Phase AC Max. Conductor Resistance per KM at 200C
WHMFDSKB_X50 0.5 16/0.20 0.6 0.9 0.9 0.9 6.2 6.6 7.2 5 83 72 39.0
WHMFDSKB_X75 0.75 24/0.20 0.6 0.9 0.9 0.9 6.5 6.9 7.6 8 56 48 26.0
WHMFDSKB_1X0 1.0 32/0.20 0.6 0.9 0.9 0.9 6.9 7.3 8.2 13 43 37 19.5
WHMFDSKB_1X5 1.5 30/0.25 0.6 0.9 0.9 1.0 7.6 8.2 9.3 18 31 26 13.3
WHMFDSKB_2X5 2.5 50/0.25 0.7 1.0 1.0 1.0 9.0 9.6 10.5 24 18 16 7.98
WHMFDSKB_4X0 4.0 56/0.30 0.8 1.0 1.0 1.0 10.3 10.9 12.3 31 11 9.6 4.95

Note : Conductor as per class V. Supplied in 100 meter lengths with black outer sheath & in bigger packing on request. Any colour on specific request can be supplied, in economical run.

The number and diameter of conductor strands are for reference only. Conductor resistance as per IS:8130 is the governing criteria.


Download Detail File : Click Here
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

Retailer of Electrical Conductor from Delhi, Delhi by Banarsi Dass Enterprises
Post Buy Requirement
BD

Banarsi Dass Enterprises

Add Review

Electrical Conductor

Our product range contains a wide range of Single Core Insulated Copper Conductor (Unsheathed) - 01, Single Core Insulated Copper Conductor (Unsheathed) - 02 and Multicore Round Insulated Copper Conductor And Sheathed

Single Core Insulated Copper Conductor (Unsheathed) - 01

Single Core Insulated Copper Conductor(Unsheathed)Flexible Cables 1100 Voltage Grade For Industrial Application

Basic Code Nominal Cross Sectional area of conductor Number/Nom. Dia of cond. strands* Thickness of Insulation (Nom) Approx. Overall Diameter Conduit/Trunking Unenclosed clipped directly to a surface or on cable trays Max. Conductor Resistance per KM at 200C
Life Line (FR) Sq. mm. mm mm mm Amps Amps Ohms
WHFFDN--B1010 10 80/0.4 1.0 6.30 50 61 1.91
WHFFDN--B1016 16 126/0.4 1.0 7.40 68 82 1.21
WHFFDN--B1025 25 196/0.4 1.2 9.10 85 103 0.780
WHFFDN--B1035 35 276/0.4 1.2 10.30 108 132 0.554
WHFFDN--B1050 50 396/0.4 1.4 12.20 144 174 0.386
Note : Conductor as per class V. 100 meter packing lengths as per IS:694 & in bigger packing on request.

The number and diameter of conductor strands are for reference only. Conductor resistance as per IS:8130 is the governing criteria.

Construction :-
Conductor : Plain annealed copper conductor as per IS:8130
Insulation
Primary - Natural Type A PVC.
Secondary - Skin colour coated PVC.(25 sq. mm & above are provided with unicolour Insulation only)
Colour : Red, Yellow, Blue, Black & Green








View Complete Details

Single Core Insulated Copper Conductor (Unsheathed) - 02

Single Core Insulated Copper Conductor (Unsheathed)Cable For Fixed Wiring 1100 Voltage Grade

Basic Code Nominal Cross Sectional area of conductor Stranding No./Nom Dia of Cond. Thickness of Insulation (Nom) Stands* Approx. Overall Diameter Conduit/Trunking Unenclosed clipped directly to a surface or on cable trays Max. Conductor Resistance per K.M. at 200C Amps
Sq. MM MM MM MM Amps Amps Ohms
WHFMDNA11X0 1.0 7/0.43 0.7 2.8 13 14 18.10
WHFMDNA11X5 1.5 7/0.52 0.7 3.1 16 19 12.10
WHFMDNA12X5 2.5 7/0.67 0.8 3.8 22 26 7.41
WHFMDNA14X0 4.0 7/0.85 0.8 4.30 29 35 4.61
WHFMDNA16X0 6.0 7/1.04 0.8 4.90 37 49 3.08
WHFMDNA1010 10 7/1.35 1.0 6.30 50 66 1.83
WHFMDNA1016 16 7/1.70 1.0 7.40 68 89 1.15
WHFMDNA1025 25 7/1.70 1.2 9.10 85 116 0.727
WHFMDNA1035 35 7/2.50 1.2 10.30 109 143 0.524
WHFMDNA1050 50 19/1.78 1.4 12.20 144 174 0.387
Note : 1-6 sq.mm in 90 mtrs. and 10-50 sq.mm. in 100 mtrs & in bigger packing on request Generally as per IS:694. Manufactured against customer's orders only for economical runs.

The number and diameter of conductor strands are for reference only. Conductor resistance as per IS:8130 is the governing criteria.

Construction
Conductor :
Plain annealed copper conductor as per IS:8130
Insulation : Primary - Natural PVC Type A PVC
Secondary - Skin colour coated PVC.
Colour : Red/Yellow/Blue/Black/Green
(25 sq. mm & above are provided with unicolour Insulation only)








View Complete Details

Multicore Round Insulated Copper Conductor And Sheathed

Multicore Round Insulated Copper Conductor And Sheathed Black Flexible Cables 1100 Voltage Grade

Basic Code Nominal Cross Sectional area of conductor MM Number Nom. Dia of cond. strands MM Thickness of Insulation (Nom) MM Sheath Two Core MM Sheath Three Core MM Sheath Four Core MM Diameter Two Core MM Diameter Three Core MM Diameter Four Core MM Current Rating AC Amps DC or Single Phase AC 3 Phase AC Max. Conductor Resistance per KM at 200C
WHMFDSKB_X50 0.5 16/0.20 0.6 0.9 0.9 0.9 6.2 6.6 7.2 5 83 72 39.0
WHMFDSKB_X75 0.75 24/0.20 0.6 0.9 0.9 0.9 6.5 6.9 7.6 8 56 48 26.0
WHMFDSKB_1X0 1.0 32/0.20 0.6 0.9 0.9 0.9 6.9 7.3 8.2 13 43 37 19.5
WHMFDSKB_1X5 1.5 30/0.25 0.6 0.9 0.9 1.0 7.6 8.2 9.3 18 31 26 13.3
WHMFDSKB_2X5 2.5 50/0.25 0.7 1.0 1.0 1.0 9.0 9.6 10.5 24 18 16 7.98
WHMFDSKB_4X0 4.0 56/0.30 0.8 1.0 1.0 1.0 10.3 10.9 12.3 31 11 9.6 4.95

Note : Conductor as per class V. Supplied in 100 meter lengths with black outer sheath & in bigger packing on request. Any colour on specific request can be supplied, in economical run.

The number and diameter of conductor strands are for reference only. Conductor resistance as per IS:8130 is the governing criteria.