Our Products
Our Complete range of products are Welding Cable, ADCAB-FR House Wire, Armoured Power Cable, Unarmoured Power Cable and ADCAB Multi Core Wire.
Working with a pool of professionals, we are offering excellent quality product from Kutch Gandhidham(India). Dedicated towards bringing forth the finest and premium quality Welding Cable, we are a well-established Supplier in this domain.
The raw materials that are used for the production of our finished products are acquired in minimally processed or unprocessed states; these are free from impurities as well. We ensure that the packing of the products remain intact and there will be zero damage while handling, warehousing and transit. For this, we make use of high quality packaging material.
Details
Nominal Area of Conductor | Number/Nom.Dia of wires* (Nom.) |
Thickness of Insulation (Nom.) |
Overall Diameter (Max) |
Current Carrying Capacity* | Resistance(Max) Km.@20°C | |
Casing | Concealed | |||||
Sq,mm | Number/mm | mm | mm | Amps | Amps | Ohm/Km |
0.75 | 24/0.20 | 0.6 | 2.5 | 8 | 7 | 26 |
1 | 14/0.30 | 0.7 | 2.8 | 12 | 11 | 18.1 |
1.5 | 22/0.30 | 0.7 | 3.1 | 16 | 13 | 12.1 |
2.5 | 36/0.30 | 0.8 | 3.8 | 22 | 18 | 7.41 |
4 | 56/0.30 | 0.8 | 4.4 | 29 | 24 | 4.95 |
6 | 84/0.30 | 0.8 | 5.2 | 37 | 31 | 3.3 |
* As per IS 3961 (PartV)-1968 and conductor as per IS-8130:1984 |
Technical Specification
FR Properties | ||
---|---|---|
Test | Specification | Value |
Critical Oxygen Index | ASTM-D 2863 | Minimum 29 |
Temperature Index | ASTM-D 2863 | Minimum 250ºC |
We have different payment options to choose from as per the convenience of the clients. In the type of operation processed online, the procedure depends on the gateway or processor model; both of them ensure complete security. We assure purchasers that our entire range is subjected to stringent quality policies to meet industry standards.
Details
Maximum Conductor temperature | 70°C |
---|---|
Ambient air temperature | 40°C |
Ground temperature | 30°C |
Depth of laying (for cables laid direct in ground) |
75 cm (1.1 KV) 90 cm (3.3, 6.6 KV) |
Thermal resistivity of soil | 150°C cm/Watt |
Thermal resistivity of ‘ATLAS’ cables | 650°C cm/Watt |
Technical Specification
No of Cores |
Overall Dia mm Nominal |
1.5 Sqmm Amp rating |
Overall Dia mm Nominal |
2.5 Sqmm Amp rating |
||
Laid in Ground | Laid in Air | Laid in Ground | Laid in Air | |||
2 | 13.5 | 23 | 20 | 15 | 32 | 27 |
3 | 13.95 | 21 | 17 | 16 | 27 | 24 |
4 | 15 | 21 | 17 | 16.4 | 27 | 24 |
5 | 16.05 | 17 | 14 | 17.4 | 23 | 19 |
6 | 17 | 15 | 13 | 18.5 | 21 | 18 |
7 | 17 | 14 | 12 | 21.85 | 20 | 17 |
10 | 20.2 | 13 | 11 | 22.2 | 17 | 15 |
12 | 20.5 | 12 | 10 | 23.3 | 16 | 14 |
14 | 20.7 | 11 | 10 | 24.35 | 16 | 13 |
16 | 21.5 | 10 | 9 | 25.6 | 15 | 12 |
19 | 22.5 | 9 | 9 | 29.1 | 14 | 12 |
24 | 24.4 | 9 | 8 | 29.6 | 13 | 11 |
27 | 25.8 | 8 | 7 | 30.6 | 12 | 10 |
30 | 26.6 | 8 | 7 | 31 | 12 | 10 |
The above Current Rating are based on IS: 3961 and Subject to all derating factors as mentioned therein or wherever applicable. Dimensions are Approximate for Guidance only and not Binding. |
Current Rating In Amps
Aluminium Conductor P.V.C. Insulated Armoured & P.V.C. Sheathed Cables for Working Voltage up to 1100 Volts as per IS: 3961 |
||||||
Conductor Dia in mm Nominal |
Laid in Ground | Laid in Air | ||||
Single Core | 2 Core | 4 Core | Single Core | 2 Core | 4 Core | |
2.5 | 17 | 18 | 16 | 15 | 16 | 13 |
4 | 31 | 32 | 28 | 27 | 27 | 23 |
6 | 39 | 40 | 35 | 35 | 35 | 30 |
10 | 51 | 55 | 46 | 47 | 47 | 40 |
16 | 66 | 70 | 60 | 64 | 59 | 51 |
25 | 86 | 90 | 76 | 84 | 78 | 70 |
35 | 100 | 110 | 92 | 105 | 99 | 86 |
50 | 120 | 135 | 110 | 130 | 125 | 105 |
Interested buyers can place orders with us, timely delivery of the same are our foremost concern. We carry out the quality examinations only under the vigil supervision of the quality auditors.
Unarmoured Power Cables, Copper Conductor (YY) To IS:1554 (Part I)
Conductor Dia in mm Nominal |
2 core | 3 core | 4 core | ||||||
Overall Diameter in mm Approx. |
Weight (Kg/Km) Approx. |
Overall Diameter in mm Approx. |
Weight (Kg/Km) Approx. |
Overall Diameter in mm Approx. |
Weight (Kg/Km) Approx. |
The following code shall be used for designating the cable | |||
1.5 | 10.5 | 145 | 11 | 170 | 11.8 | 204 | Constituent | Code Letter | |
2.5 | 12 | 185 | 12.3 | 210 | 13.8 | 270 | Aluminum conductor | A | |
4 | 14.1 | 245 | 14.5 | 300 | 15.9 | 366 | PVC Insulation | Y | |
6 | 14.2 | 310 | 15 | 350 | 16.3 | 475 | Steel round wire armour | W | |
10 | 16.5 | 421 | 16.8 | 525 | 18.3 | 666 | Steel strip armour | F | |
16 | 19 | 625 | 20.5 | 803 | 22.4 | 1010 | Steel double round wire armour | WW | |
Steel double strip armour | FF | ||||||||
Unarmoured Power Cables, Aluminium Conductor (AYY) to IS:1554 (Part I) | PVC Sheath | Y |
Unarmoured Power Cables, Aluminium Conductor (AYY) To IS:1554 (Part I)
Conductor Dia in mm Nominal |
2 core | 3 core | 4 core | ||||
Overall Diameter in mm Approx. |
Weight (Kg/Km) Approx. |
Overall Diameter in mm Approx. |
Weight (Kg/Km) Approx. |
Overall Diameter in mm Approx. |
Weight (Kg/Km) Approx. |
||
2.5 | 11.8 | 175 | 12.4 | 190 | 13.3 | 220 | |
4 | 13.1 | 220 | 13.8 | 240 | 14.8 | 280 | |
6 | 14.2 | 260 | 15 | 280 | 16.5 | 330 | |
10 | 15.7 | 320 | 16.6 | 350 | 18 | 420 | |
16 | 18.8 | 460 | 20.4 | 530 | 22.5 | 640 | |
25 | 23 | 550 | 21.2 | 600 | 24.1 | 710 |
As we are the name on which the customers lay their trust for quality, as we are supplying the finest ADCAB Multi Core Wire. The offered lot is prepared using the best in class raw material that is sourced from the reliable places only. Besides, we check it for quality prior to procurement.
Technical Specification
Plain Copper Conductor, PVC Insulated and Sheathed 1100V Multicore Flexible Cables | ||||||||||||
Area in Sq. mm. |
Construction No./Dia Nominal |
Conductor Dia in mm Nominal |
Max. DC resistance Ohm/Km at 20°C | Insulation Thickness In mm Nominal |
Core Dia. mm |
Current Rating in Amps. | Sheath Thickness in mm nominal | Overall Diameter in mm approx. | ||||
2 core |
3 core |
4 core |
2 core |
3 core |
4 core |
|||||||
0.5 | 16/0.2 | 0.94 | 39 | 0.6 | 2.2 | 4 | 0.9 | 0.9 | 0.9 | 6.2 | 6.6 | 7.2 |
0.75 | 24/0.2 | 1.2 | 26 | 0.6 | 2.5 | 7 | 0.9 | 0.9 | 0.9 | 6.8 | 7.2 | 7.9 |
1 | 32/0.2 | 1.34 | 19.5 | 0.6 | 2.6 | 11 | 0.9 | 0.9 | 0.9 | 7 | 7.5 | 8.1 |
1.5 | *30/0.25 | 1.64 | 13.3 | 0.6 | 2.9 | 14 | 0.9 | 0.9 | 1 | 7.6 | 8.1 | 9 |
2.5 | **50/0.25 | 2.08 | 7.98 | 0.7 | 3.5 | 19 | 1 | 1 | 1 | 9 | 9.6 | 10.5 |
4 | 56/0.3 | 2.61 | 4.95 | 0.8 | 4.3 | 26 | 1 | 1 | 1 | 10.6 | 11.3 | 12.4 |
6 | 84/0.3 | 3.5 | 3.3 | 0.8 | 5.1 | 33 | 1.15 | 1.15 | 1.4 | 12.6 | 13.4 | 15.2 |
10 | 140/0.3 | 4.6 | 1.91 | 1 | 6.6 | 45 | 1.4 | 1.4 | 1.4 | 16 | 17 | 18.8 |
16 | 126/0.4 | 6 | 1.21 | 1 | 8 | 60 | 1.4 | 1.4 | 1.4 | 18.8 | 20.1 | 22.2 |
25 | 196/0.4 | 7.6 | 0.78 | 1.2 | 10 | 75 | 2 | 2 | 2 | 24 | 25.6 | 28.2 |
35 | 276/0.4 | 8.7 | 0.55 | 1.2 | 11.1 | 95 | 2 | 2 | 2 | 26.3 | 28 | 31 |
50 | 396/0.4 | 10.6 | 0.39 | 1.4 | 13.4 | 125 | 2 | 2 | 2 | 30.9 | 33 | 36.5 |
70 | 360/0.5 | 12.3 | 0.27 | 1.4 | 15.1 | 170 | 2 | 2.2 | 2.4 | 34.2 | 37 | 41 |
95 | 485/0.5 | 14.7 | 0.21 | 1.6 | 17.9 | 210 | 2.2 | 2.4 | 2.4 | 40.2 | 43.5 | 47.8 |
* This size can be supplied in 48/0.2 construction. ** This size can be supplied in 80/0.2 construction. |
||||||||||||
Dimensions are Approximate for Guidance only and not Binding. As per IS 694 cables. |
We are Kutch Gandhidham(India) based organization and have become the primary choice of the buyers since our products are qualitative. Our company has worked hard to establish an efficient distribution network. Therefore, buyers can order the product in mass and expect on time delivery.
Technical Specification
Construction Parameters | Cable Type | ||||
Approx. Overall Diameter | 2 Pair/3.50mm | 3 Pair/4.20mm | 4 Pair/5.30mm | 5 Pair/6.00mm | 10 pair/8.50mm |
Conductor Diameter | Solid Annealed Bare Copper, 24AWG (0.5mm) | ||||
Insulation Material | High Density Polyethylene | ||||
PVC Jacket | Flame Retardant PVC |
Details
Contruction Parameters | Cable Type | ||
RG 11F | RG 6F | RG 59F | |
Center Conductor Nom. Dia. (mm) |
Solid bare copper 1.63 |
Solid bare copper 1.02 |
Solid bare copper 0.80 |
Dielectric Nom. Dia. (mm) |
Chemical, Air Space, Solid PE 7.11 |
Chemical, Air Space, Solid PE 4.57 |
Chemical, Air Space, Solid PE 3.55 |
Outer Conductor 1st Shield 2nd Shield Min. Coverage (%) |
Al-Foil Bonded ATC braiding 60 |
Al-Foil Bonded ATC braiding 60 |
Al-Foil Bonded ATC braiding 60 |
Flooding Compound | Jelly if required | Jelly if required | Jelly if required |
Jacket Nom. Dia. (mm) |
Black PVC 10.30 |
Black PVC 7.25 |
Black PVC 6.20 |
Bending radius (mm) | 70 | 60 | 70 |
Technical Specification
Electrical Parameters | Cable Type | ||
RG 11F | RG 6F | RG 59F | |
Center conductor (Max. resistance at 20°) |
0.85 ohm/100 mtr. | 2.14 ohm/100 mtr. | 3.55 ohm/100 mtr |
Nom. Capacitance (PF/Mtrs.) |
53 ± 3 | 53 ± 3 | 53 ± 3 |
Characteristics Impedance (Ohms) |
75 ± 3 | 75 ± 3 | 75 ± 3 |
Nom. Velocity Ratio (%) | 85 | 85 | 85 |
Attenuation @ 20°c (db/100 Mtrs.) at | |||
865 MHz | 13.05 db | 19.95 db | 24.67 db |
1000 MHz | 14.27 db | 21.45 db | 26.64 db |
All figures are approximate presentation and may show variation under different conditions. |
Details
Nominal Area of Conductor | Number/Nom.Dia of wires* (Nom.) |
Thickness of Insulation (Nom.) |
Overall Diameter (Max) |
Current Carrying Capacity* | Resistance(Max) Km.@20°C | |
Casing | Concealed | |||||
Sq,mm | Number/mm | mm | mm | Amps | Amps | Ohm/Km |
1 | 14/0.30 | 0.7 | 2.8 | 12 | 11 | 18.1 |
1.5 | 22/0.30 | 0.7 | 3.1 | 16 | 13 | 12.1 |
2.5 | 36/0.30 | 0.8 | 3.8 | 22 | 18 | 7.41 |
4 | 56/0.30 | 0.8 | 4.4 | 29 | 24 | 4.95 |
6 | 84/0.30 | 0.8 | 5.2 | 37 | 31 | 3.3 |
6 | 84/0.30 | 0.8 | 5.2 | 37 | 31 | 3.3 |
* As per IS 3961 (PartV)-1968 and conductor IS 8130:1984 |
Technical Specification
FR Properties | ||
---|---|---|
Test | Specification | Value |
Critical Oxygen Index | ASTM-D 2863 | Minimum 29 |
Temperature Index | ASTM-D 2863 | Minimum 250ºC |
Acid Gas Generation | IEC 754 | Maximum 20 |
Smoke Density | ASTM-D2843 | Maximum 60 |
Details
Nominal Area of Conductor | Number/Nom.Dia of wires* (Nom.) |
Thickness of Insulation (Nom.) |
Overall Diameter (Max) |
Current Carrying Capacity* | Resistance(Max) Km.@20°C | |
Casing | Concealed | |||||
Sq,mm | Number/mm | mm | mm | Amps | Amps | Ohm/Km |
1 | 14/0.30 | 0.7 | 2.8 | 12 | 11 | 18.1 |
1.5 | 22/0.30 | 0.7 | 3.1 | 16 | 13 | 12.1 |
2.5 | 36/0.30 | 0.8 | 3.8 | 22 | 18 | 7.41 |
4 | 56/0.30 | 0.8 | 4.4 | 29 | 24 | 4.95 |
6 | 84/0.30 | 0.8 | 5.2 | 37 | 31 | 3.3 |
* As per IS 3961 (PartV)-1968 and conductor IS 8130:1984 |
FR Properties
Test | Specification | Value |
---|---|---|
Critical Oxygen Index | ASTM-D 2863 | Minimum 29 |
Temperature Index | ASTM-D 2863 | Minimum 250ºC |
Acid Gas Generation | IEC 754 | Maximum 5 |
Smoke Density | ASTM-D2843 | Maximum 20 |
We have separated our infrastructural facility into several units and one of them in warehouse. In order to maintain high quality standards, we laced our facility with modern technology. Keen on procurement of ADCAB LT XLPE Wire? We are one of the well known ADCAB LT XLPE Wire Suppliers
Details
IS 1554 (PART I )- 1988 | |||
Construction of Conductor | |||
Nominal Cross Sectional Area of Conductor (mm²) | Solid / Stranded | Flexibility Class Ref to IS :8130 1984 | |
Copper mm² | Aluminium mm² | ||
1.5 | Solid | Class -1 | |
1.5 to 6 | 2.5 to 10 | Solid / Stranded | Class 1 for solid or Class 2 for stranded |
10 and Above | 16 and Above | Stranded | Class 2 |
Technical Specification
Thickness of Insulation ( mm ) AS PER IS 1554 (PART-1) | |
The following code shall be used for designationg the cable | |
Constitutent | Code Latter |
Aluminium conductor | A |
PVC Insulation | Y |
Steel round wire armour | W |
Steel strip armour | F |
Steel double round wire armour | WW |
Steel double strip armour | FF |
PVC Sheath | Y |
Technical Data
Type of cable | Legend |
i) Improved fire performance or Category C1 | FR |
ii) Improved fire performance or Category C2 | FR-LSH |