Frequency Relays

Operations of the relay can be tested by means of a test, button which energies the output relays & LEDs after set time delay with the channels set to underover frequency operation. Access to the test push button requires removal of the front cover. This test facility should normally only be used with the relay trip circuits isolated, The relays are suitable for any application in industrial plants & to generators where definite time underover frequency protection is required.
View Complete Details

Numerical Under Frequency Relay

  • AC voltage rating 110, 220 VAC
  • Auxiliary supply voltage 30-220 V DC
  •  Frequency setting range 39.00 to 70. 00 Hz in step of .1Hz
  • Operating voltage range     33 to 135 V the relay is block   below this limit
  • No of tripped stage       2 for UFT -21   3 for UFT -31 4 for UFT- 41
  • Reference frequency 4 MHZ
  • Accuracy     + .03 Hz    
  • Reset Ratio     100%    
  • Timer Range     .05 to 7.35 Sec. for under & over   Frequency stage.
  • Burden  
  •  Aux Supply from PT     1.5 VA    
  •    
  • Aux Supply from external source 1.5 VA max at 150 V
  •  Aux DC (without tripping relays) 11 W for 4 stages
  • Contacts in relay             3 pair of N/O contact make & carry   7500 VA for 0. 25 with maxima of 30 A & 300 VAC or DC Carry contentiously 5 A AC/DC. Break 1250 VA AC/50 W DC resistive, 25 W L/R = 0. 04 S. Subject to maxima of 5A & 300 V
  • Test Voltage 2 kv/50 Hz 1 min.   5kv 1.2/50 us
  • Reduced values are valid   in case of repeat testing casing Does not apply to the terminal connected to a common Aux supply.    
  • Casing     Flush mounting with rear connection   96x 192 / 192 x 192 x 200/250 mm W                    H                    D
  • Guaranteed operation – 10 + 55° C

A switch is provided to select either an independent made of operation of three or four channels or select the under/over frequency made of operation.

The test switch, tripping indications & reset button are provided on the front of Relay.

The relays are suitable for any application in industrial plants & to generators where definite time under/over frequency protection is required

Internal timers are provided for each operating circuits & separate aux. Relays ensure maximum flexibility of operation.

Internal event recording of last three event. The values of parameters at the moment of tripping are recorded on the display.

Two terminals are provided for the voltage input to the frequency sensing circuit the measurement of the frequency is digital for which only the zero crossing of the system voltage & not its amplitude are of consequence the relay is independent of the voltage fluctuations with a wide range. However the system voltage sink below a predetermined value in which the accurate measurement can no longer be expected the under voltage blocking circuit blocks all the outputs.

Operations of the relay can be tested by means of a test, button which energies the output relays & LEDs after set time delay with the channels set to under/over frequency operation. Access to the test push button requires removal of the front cover. This test facility should normally only be used with the relay trip circuits isolated

Features
  • Low Burden
  • Wide operating voltage range
  • Wide frequency setting range 39. 00 to 70. 00 Hz
  • Independently adjustable tripping stages.
  • Consistent accuracy ( .03 Hz)
  • Unaffected by voltage fluctuations
  • Insensitive to harmonics & transient
  • Built in timer(.1 to 99.9 Sec.)
  • Built in event recorder for last three events.
  • Under frequency & over frequency relay with 2 to 4 frequency stages.
  • Adjustable under voltage blocking level.
  • Field Adjustable relay rated frequency
  • One operate time can give to each frequency stage.
  • Protection stages can be separately blocked via internal blocking inputs.
View Complete Details

Frequency Trend Relay

  • AC voltage rating 110, 220VAC
  • Auxiliary supplyvoltage From PT 66 to 135 V External 35 to 135 of PT
  • Frequency setting range 39.0 to 60.0 Hz in step of 1 Hz
  • Under frequency setting (dfdt) 1 Hz Sec to 9.9 H:: Sec at 50 Hz
  • Operating voltage range       66 to 135   35-to 135 V The relay is blocked below & above this limit
  • No. of tripped stageUFTR -51   UFTR-41 UFTR-6 I   4. Two of which have dfdt output   One of which have dfdt output 4 No. of dfdt output  
  • Reference frequency 5 MHz
  • Accuracy .03 Hz at 50 Hz
  • Reset ratio 100% (Digital)
  • Max reset time under &Overfrequency 50 ms
  • Tripping delay for dfdt stage 5 cs to 9 cs unless stated set to 6 cs on delivery
  • Evaluation period for delivery dfdt stages 26 52 mSunless stated set to 26 mS On

ARMO-UFTR Frequency relays are used-to monitor the frequency of an electrical System. Due to inadvertent splitting of inner connection in power system. Isolated areas of the system may become deficient in the generation and frequency of the same may drop considerably giving rise to emergency conditions. In order to maintain control of system under this low frequency emergency, some form of graded load shedding is needed. ARMO-UFTR relay is used to detect such conditions and initiate load shedding to prevent complete system collapse.

Type UFTR-41 consists of two/three definite time fully independent frequency measuring stage and one df/dt stage.

Type UFTR-51 consists of two/three definite time fully independent frequency measuring stage and one df/dt stage.

Separate Auxiliary relays are provided which get energized after the respective time delays (In case of df/dt the tripping frequency gradient). Tripping indications and reset push button are provided on the front of the relay.

The relays are suitable for any application in industrial plants and to generators where definite time under over frequency protection with df/dt stage is required.

Internal timers are provided for each operating circuits and separate aux relays ensure maximum flexibility of application.

Two terminals are provided for the voltage input to the frequency sensing circuit. The measurement of the frequency is digital for which only the zero-crossing of the system voltage and not its amplitude, are of consequence. The relay is independent of the voltage fluctuations with a wide range. However the system voltage sink below a predetermined value in which the accurate measurement can no longer be expected the under voltage blocking circuit blocks all the outputs

Silent Features
  • Low burden
  • Wide operating voltage range
  • Wide frequency setting range 39.00 to 70.00 Hz
  • Independently adjustable tripping stages two of which have a rate of change of frequency function.
  • Consistent accuracy = +-0.03 Hz at 50 Hz
  • Unaffected by voltage fluctuations
  • Insensitive to harmonics & Transient
  • Built in self-test mode
  • Built in timer .02 to .18 sec.
View Complete Details

Tripping Relay

We already have a wide network of Distributors & Dealers all over the country. They all have sufficient trained manpower with them which ensures best support to our customer. The process of appointing dealers distributors in unrepresented areas is on and continuous efforts are made to expand our base on this line.
View Complete Details

Auxiliary Relays

Two terminals are provided for the voltage input to the frequency sensing circuit the measurement of the frequency is digital for which only the zero crossing of the system voltage & not its amplitude are of consequence the relay is independent of the voltage fluctuations with a wide range. However the system voltage sink below a predetermined value in which the accurate measurement can no longer be expected the under voltage blocking circuit blocks all the outputs.One operate time can give to each frequency stage.
View Complete Details

Undervoltage Relay

Internal event recording of last three event. The values of parameters at the moment of tripping are recorded on the display.Internal timers are provided for each operating circuits & separate aux. Relays ensure maximum flexibility of operation.ARMO UFT relay is used to detect such condition & initiate load shedding to prevent complete system collapse.
View Complete Details

Voltage Relays

Operations of the relay can be tested by means of a test, button which energies the output relays & LEDs after set time delay with the channels set to underover frequency operation. Access to the test push button requires removal of the front cover. This test facility should normally only be used with the relay trip circuits isolated, ARMO UFT frequency relays are used to monitor the frequency of an electrical system. Due to inadvertent splitting of inner connection in power system, isolated areas of the system may become deficient in the generation & frequency of the same may drop considerably giving rise to emergency conditions.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

Retailer of Relays from Nagpur, Maharashtra by ARMO Electronics & Electricals (I)
Post Buy Requirement
AE

ARMO Electronics & Electricals (I) Nagpur, Maharashtra

Nagpur, Maharashtra, India
Add Review

Relays #5531317

Our Complete range of products are frequency relays, Numerical under frequency relay, Frequency Trend Relay, Tripping Relay and Auxiliary Relays.

Frequency Relays

Operations of the relay can be tested by means of a test, button which energies the output relays & LEDs after set time delay with the channels set to underover frequency operation. Access to the test push button requires removal of the front cover. This test facility should normally only be used with the relay trip circuits isolated, The relays are suitable for any application in industrial plants & to generators where definite time underover frequency protection is required.
View Complete Details

Numerical Under Frequency Relay

  • AC voltage rating 110, 220 VAC
  • Auxiliary supply voltage 30-220 V DC
  •  Frequency setting range 39.00 to 70. 00 Hz in step of .1Hz
  • Operating voltage range     33 to 135 V the relay is block   below this limit
  • No of tripped stage       2 for UFT -21   3 for UFT -31 4 for UFT- 41
  • Reference frequency 4 MHZ
  • Accuracy     + .03 Hz    
  • Reset Ratio     100%    
  • Timer Range     .05 to 7.35 Sec. for under & over   Frequency stage.
  • Burden  
  •  Aux Supply from PT     1.5 VA    
  •    
  • Aux Supply from external source 1.5 VA max at 150 V
  •  Aux DC (without tripping relays) 11 W for 4 stages
  • Contacts in relay             3 pair of N/O contact make & carry   7500 VA for 0. 25 with maxima of 30 A & 300 VAC or DC Carry contentiously 5 A AC/DC. Break 1250 VA AC/50 W DC resistive, 25 W L/R = 0. 04 S. Subject to maxima of 5A & 300 V
  • Test Voltage 2 kv/50 Hz 1 min.   5kv 1.2/50 us
  • Reduced values are valid   in case of repeat testing casing Does not apply to the terminal connected to a common Aux supply.    
  • Casing     Flush mounting with rear connection   96x 192 / 192 x 192 x 200/250 mm W                    H                    D
  • Guaranteed operation – 10 + 55° C

A switch is provided to select either an independent made of operation of three or four channels or select the under/over frequency made of operation.

The test switch, tripping indications & reset button are provided on the front of Relay.

The relays are suitable for any application in industrial plants & to generators where definite time under/over frequency protection is required

Internal timers are provided for each operating circuits & separate aux. Relays ensure maximum flexibility of operation.

Internal event recording of last three event. The values of parameters at the moment of tripping are recorded on the display.

Two terminals are provided for the voltage input to the frequency sensing circuit the measurement of the frequency is digital for which only the zero crossing of the system voltage & not its amplitude are of consequence the relay is independent of the voltage fluctuations with a wide range. However the system voltage sink below a predetermined value in which the accurate measurement can no longer be expected the under voltage blocking circuit blocks all the outputs.

Operations of the relay can be tested by means of a test, button which energies the output relays & LEDs after set time delay with the channels set to under/over frequency operation. Access to the test push button requires removal of the front cover. This test facility should normally only be used with the relay trip circuits isolated

Features
  • Low Burden
  • Wide operating voltage range
  • Wide frequency setting range 39. 00 to 70. 00 Hz
  • Independently adjustable tripping stages.
  • Consistent accuracy ( .03 Hz)
  • Unaffected by voltage fluctuations
  • Insensitive to harmonics & transient
  • Built in timer(.1 to 99.9 Sec.)
  • Built in event recorder for last three events.
  • Under frequency & over frequency relay with 2 to 4 frequency stages.
  • Adjustable under voltage blocking level.
  • Field Adjustable relay rated frequency
  • One operate time can give to each frequency stage.
  • Protection stages can be separately blocked via internal blocking inputs.
View Complete Details

Frequency Trend Relay

  • AC voltage rating 110, 220VAC
  • Auxiliary supplyvoltage From PT 66 to 135 V External 35 to 135 of PT
  • Frequency setting range 39.0 to 60.0 Hz in step of 1 Hz
  • Under frequency setting (dfdt) 1 Hz Sec to 9.9 H:: Sec at 50 Hz
  • Operating voltage range       66 to 135   35-to 135 V The relay is blocked below & above this limit
  • No. of tripped stageUFTR -51   UFTR-41 UFTR-6 I   4. Two of which have dfdt output   One of which have dfdt output 4 No. of dfdt output  
  • Reference frequency 5 MHz
  • Accuracy .03 Hz at 50 Hz
  • Reset ratio 100% (Digital)
  • Max reset time under &Overfrequency 50 ms
  • Tripping delay for dfdt stage 5 cs to 9 cs unless stated set to 6 cs on delivery
  • Evaluation period for delivery dfdt stages 26 52 mSunless stated set to 26 mS On

ARMO-UFTR Frequency relays are used-to monitor the frequency of an electrical System. Due to inadvertent splitting of inner connection in power system. Isolated areas of the system may become deficient in the generation and frequency of the same may drop considerably giving rise to emergency conditions. In order to maintain control of system under this low frequency emergency, some form of graded load shedding is needed. ARMO-UFTR relay is used to detect such conditions and initiate load shedding to prevent complete system collapse.

Type UFTR-41 consists of two/three definite time fully independent frequency measuring stage and one df/dt stage.

Type UFTR-51 consists of two/three definite time fully independent frequency measuring stage and one df/dt stage.

Separate Auxiliary relays are provided which get energized after the respective time delays (In case of df/dt the tripping frequency gradient). Tripping indications and reset push button are provided on the front of the relay.

The relays are suitable for any application in industrial plants and to generators where definite time under over frequency protection with df/dt stage is required.

Internal timers are provided for each operating circuits and separate aux relays ensure maximum flexibility of application.

Two terminals are provided for the voltage input to the frequency sensing circuit. The measurement of the frequency is digital for which only the zero-crossing of the system voltage and not its amplitude, are of consequence. The relay is independent of the voltage fluctuations with a wide range. However the system voltage sink below a predetermined value in which the accurate measurement can no longer be expected the under voltage blocking circuit blocks all the outputs

Silent Features
  • Low burden
  • Wide operating voltage range
  • Wide frequency setting range 39.00 to 70.00 Hz
  • Independently adjustable tripping stages two of which have a rate of change of frequency function.
  • Consistent accuracy = +-0.03 Hz at 50 Hz
  • Unaffected by voltage fluctuations
  • Insensitive to harmonics & Transient
  • Built in self-test mode
  • Built in timer .02 to .18 sec.
View Complete Details

Tripping Relay

We already have a wide network of Distributors & Dealers all over the country. They all have sufficient trained manpower with them which ensures best support to our customer. The process of appointing dealers distributors in unrepresented areas is on and continuous efforts are made to expand our base on this line.
View Complete Details

Auxiliary Relays

Two terminals are provided for the voltage input to the frequency sensing circuit the measurement of the frequency is digital for which only the zero crossing of the system voltage & not its amplitude are of consequence the relay is independent of the voltage fluctuations with a wide range. However the system voltage sink below a predetermined value in which the accurate measurement can no longer be expected the under voltage blocking circuit blocks all the outputs.One operate time can give to each frequency stage.
View Complete Details

Undervoltage Relay

Internal event recording of last three event. The values of parameters at the moment of tripping are recorded on the display.Internal timers are provided for each operating circuits & separate aux. Relays ensure maximum flexibility of operation.ARMO UFT relay is used to detect such condition & initiate load shedding to prevent complete system collapse.
View Complete Details

Voltage Relays

Operations of the relay can be tested by means of a test, button which energies the output relays & LEDs after set time delay with the channels set to underover frequency operation. Access to the test push button requires removal of the front cover. This test facility should normally only be used with the relay trip circuits isolated, ARMO UFT frequency relays are used to monitor the frequency of an electrical system. Due to inadvertent splitting of inner connection in power system, isolated areas of the system may become deficient in the generation & frequency of the same may drop considerably giving rise to emergency conditions.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us