Post Buy Requirement
Angel Medical Equipment

Angel Medical Equipment

gstGST : 27AIPPG0212M2Z9 Verified Add Review

NICU Radiant Heat Warmers

NICU Equipments

Infant Baby Warmer

  • Electrical Specifications 220-240 VAC, 50/60 Hz
  • Pre heating mode Fixed at 30%
  • Temperature measurement accuracy ±-0.2°C
  • Skin probe accuracy ±0.1°C (Range 25° to 45°C)
  • Temperature display resolution ±0.1°C
Ampala 2081 Fanem
View Complete Details

Infant Radiant Warmer

  • Material Metal
  • Voltage 220 V AC. 50 Hz
  • Condition New
  • Finishing Polished
  • Warranty 1 Year
  • Heater Power 650Watts
View Complete Details

Ampala Baby Warmer

  • Electrical Specifications 220-240 VAC, 50/60 Hz
  • Pulse Rate 10 to 250BPM
  • Pre heating mode Fixed at 30%
  • Temperature measurement accuracy ±-0.2°C
  • Skin probe accuracy ±0.1°C (Range 25° to 45°C)
  • Temperature display resolution ±0.1°C

Display specifications

  • Microprocessed Seven Segment LED display
  • Microprocessed Monochromatic Graphic Display Monitor 5.5" (OPT)
  • Microprocessed Colorful Graphic Display Monitor 8.4" (OPT)


Microprocessor control system

  • Three modes of operation
  • Skin or servo mode
  • Manual mode
  • Pre-heating mode
  • Skin or servo mode control range - 34°C to 38°C
  • Manual mode - Heater Output adjustable from 0-100% in 10% increments
  • Pre heating mode - Fixed at 30%
  • Auto test function performed at power on
  • Temperature measurement accuracy - ±-0.2°C
  • Skin probe accuracy - ±0.1°C (Range 25° to 45°C)
  • Temperature display resolution - ±0.1°C
  • Heating element - 560W
  • Heater warmup time at 100% power less than 2 mins
  • Auxiliary LED light


Physical characteristics

  • Height - 1886mm to 2086mm (Optional)
  • Depth - 1143mm
  • Width - 1000mm
  • Height -1800mm
  • Mechanical Light adjustment of bed in 3 steps by technical position
  • Two drawer storage system
  • Bed tilting - ± 12°
  • Continuous Electrical tilting - ± 12°(Optional)
  • Mattress - 65 X 45 X 5cm
  • Bearer Reel. for Wires
  • Auxiliary tray
  • Infusion pump stand
  • IV pole


Weighing scale specifications (OPT)

  • Range - 200 gms to 10kg
  • Accuracy: -±4gm


T-piece resuscitator specifications (OPT)

  • Manometer:-20 to 80cm 620
  • Maximum Pressure - 70cm 620
  • PIP - 5 to 70cm 820 @ 8LPM
  • PEEP - 2 to 10cm H20 @ 8LPM
  • Gas inlet floss range - SLPM (min) to 15LPM (max)
  • 02 concentration - 21% to 100% depending on the inlet gas source


Air Venturi Suction (OPT)

  • Range - 0 to 180mmHg
  • Accuracy: ± 5%


Blender (OPT)

  • Range - 21% to 100%
  • Accuracy - ± 3%


Bilitron 3006 BTB (OPT)

  • Integrated top surface phototherapy
  • Five super LED's
  • Irradiance - 30 to 40uw/crn2.nm


Bilitron Bed for Ampla

  • Integrated under surface phototherapy 8 super LED
  • Gel mattress
  • Irradiance - 30 to 45 uw/cm'.nm


Pulse Oxymeter (OPT)

  • Nelcore technology
  • Measurement range - SPO2 : 21 to 100%
  • Pulse Rate - 10 to 250BPM
  • SPO2 Accuracy - From 70 to 100%, °2 digits
  • Pulse rate
  • With motion: 05 digits


Environmental conditions (OPT)

  • Operating temperature -19°C to 30°C
  • Operating humidity: 15% to 95% - No Condensative
View Complete Details

Radiant Warmer

2.75 Lakh - 5 Lakh /Unit Get Latest Price
  • Min. Order (MOQ) 01 Piece
Ampla 2085 Warmer from Fanem.
View Complete Details

Fanem Baby Warmer

  • Electrical Specifications 220-240 VAC, 50/60 Hz
  • Operating temperature 19°C to 30°C
  • Operating humidity 15% to 95% - No Condensative
  • Modes of Operation Three
  • Pre heating mode Fixed at 30%
  • Temperature measurement accuracy ±0.2°C
  • Skin probe accuracy ±1°C (Range 25" to 45°C)

Features

  • Microprocessed Seven Segment LED display
  • Microprocessed Monochromatic Graphic Display Monitor
  • Microprocessed Colorful Graphic Display Monitor 8.4"


Control system

  • Three modes of operation
  • Skin or servo mode
  • Pre-heating mode
  • Skin or servo mode control range: 34°C to 38°C
  • Manual mode - Heater Output adjustable from 0-100% in
  • Pre heating mode - Fixed at 30%
  • Auto test function performed at Power on
  • Temperature measurement accuracy - ±0.2°C
  • Skin probe accuracy - ±1°C (Range 25" to 45°C)
  • Temperature display resolution - ±0.1°C
  • Heating element - 560W
  • Heater warmup time at 100% power in less than 2 mins
  • Auxiliary LED light


Physical characteristics

  • Height - 1886mm to 2086mm (Optional)
  • Depth - 1143rnrnWidth: 1000mm
  • Two drawer storage system(Optional)
  • Continuous Electrical tilting: t 12"(Optional)
  • Mattress: 65 X 45 X 5cm
  • Infusion pump stand


Weighing scale specifications

  • Range - 200 gms to 10kg
  • Accuracy: ±4gm


Bilitron Bed for Ample

  • Integrated under surface phototherapy
  • Gel mattress
  • 8 super LED's
  • Irradiance: 30 to 45 uw/cninm


T-piece resuscitator specifications (Optional)

  • Manometer  -20 to 80cm H2O
  • Maximum Pressure - 70cm H2O
  • PIP - 5 to 70cm H2O @ 8LPM
  • PEEP - 2 to 10cm H2O @ 8LPM
  • Gas inlet flow range - 5LPM (min) to 15LPM (max)
  • 02 concentration - 21% to 100% depending on the inlet gas source


Blender (Biomed.USFD A approved) (Optional)

  • Range: 21% to 100%
  • Accuracy, ± 3%
  • Minimum input gas supply pressure - 25PSI


Bilitron 3006 BTB(Optional)

  • Integrated top surface phototherapy
  • Five super LED's
  • Irradiance 30 to 40uw/cni nm
View Complete Details

Infant Radiant Baby Warmer

  • Dimesnions 85 cms(L) x70 cms(W)x185 cms(H)
  • Weight 70 Kgs (nice 2010BC)
  • Mattress 73 cms (L) x 53 cms (W) x 5 cms (H)
  • Mattress from floor 95 cms
  • Maximum load 10 Kgs
  • Side panels Aluminum hinged acrylic panels
  • Maximum load for monitor shelf 4.5 Kgs
  • Heater module swivel ±90 Degree

Features:

  • Micro Controller based Electronics
  • Controls - Servo Skin/ Apgar
  • Pre-warm - Use the equipment with 30% Heater Output in Manual Mode.
  • Programmable Mute time
  • No need of calibration required for temperature probe.
  • High Intensity Quartz Heating element for effective Radiation (Ceramic heater Optional)
  • Halogen Observation Lamp
  • The Heater Module rotates 90° to both sides to facilitate
  • X-Ray Procedures.
  • The Parabolic Reflector is designed to send uniform heat to the bed surface.
  • Memory Backup to restore set temperature and previous mode, in case of power failure.
  • Optimum Bed dimensions ensure optimum work space for the nursing staff.
  • Comprehensive Alarms and safety cut-offs.
  • Alert (Alarm) when sensor is detached from the patient's skin (optional)
  • Instant Warming and Uniform heating

 

Controller

  • Electronics : High speed micro controller
  • Mode of operation : Servo skin, manual & apgar
  • Skin mode control range : 30 Deg. C to 38 Deg. C
  • Manual mode timer : 1 min to 15 mins (selectable), 15 mins to 30 mins (optional)
  • Apgar timer : Alerts at 1, 5, 10, 15 & 20 mins (selectable)
  • Percentage of heater output : 10% to 100% in 10% increments
  • Memory back up : Equipment restores the previous settings
  • Programmable mute time : User can select the mute time
  • Safety heater cut off : If the skin sensor is removed from the baby's skin
  • Over temperature heater cut off : If the skin temperature is >39 Deg. C in any skin/manual mode
  • Temperature sensor (probe) : Thermistor sensor
  • Accuracy of skin sensor : ±0.1 C
  • Accuracy of skin probe Interchangeability : 0.2 C
  • Calibration of skin sensor (probe) : No need of calibration after Changing new probe
  • Heater element : Quartz Infrared heater Ceramic heater (optional)


Other Details

  • Power rating : 230V AC, 50Hz, 700 W
  • Maximum heater wattage : 600 Watts
  • Maximum power requirement : 700 Watts
  • Examination light : 12V, 50W Halogen lamp
  • X-ray facility : Underneath the bed
  • Mattress tilt : ±30 degrees on both sides
  • IV pole : Maximum load 2.2 Kg
  • Pump mounting pole : Maximum load 2.2 Kg
  • Castor : 4” castors 4 Nos. (2 with brake & 2 without brake
  • Monitor shelf : 2 Nos. Fixed
  • Height adjustable heater module : Available only in nice 2010
  • Cabinet : Available only in nice 2010BC
  • Operating noise level : <50 dBA


Controller Alarms:

  • Check patient If the skin sensor is removed from
  • the baby's skin
  • Skin temperature high > 1.0 C from the set temperature
  • Skin temperature low < 1.0 C from the set temperature
  • Skin temperature probe fail Probe short or open
  • Over temperature If skin temperature is 39 C
  • Heater fail Heater defect
  • System fail Electronic component defect
  • Power fail AC power interruption


Environmental

  • Operating temperature - 15° C to 35° C
  • Storage temperature - -20° C to 60° C
  • Operating humidity - 5% to 90% RH, non condensing
  • Storage humidity - 0% to 99% RH, non condensing
  • Altitude - Sea level to 1-9 miles, 3 Km
  • Quality - ISO 9001:2000 & ISO 13485:2003
  • Electrical & product safety - IEC 60601-1, IEC 60601-1-2, IEC 60601-1-4, IEC 60601-2-21
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us