Post Buy Requirement
AE
Pune, Maharashtra, India
Add Review

Other Products / Services #346766

Frequency Indicators

Frequency indicators are designed to display RPM of motors. The instruments accepts the inputs directly from proximity switches, alternators or magnetic pick-up sensors. These instruments are microcontroller based to give high accuracy & easy to handle. High or Low alarm can be given if required.
View Complete Details

Thermocouple Probes

300 /Piece Get Latest Price
  • Min. Order (MOQ) 10 Piece(s)
  • Cable Type Straight
  • Probe Type Type K
  • Brand Name Analogik
View Complete Details

Universal Calibrator

Analogik universal calibrator is very useful tool to calibrate many types of process control instruments which accepts mV and mA and resistance. The universal calibrator is designed to give highest stability and accuracy. The calibrator can be used for lab or inhouse purpose as well as to used on field. This is very useful tool for calibration of instruments, commissioning, quality assurance and fault findings.
View Complete Details

UNIVERSAL CALIBRATORS AND SIMULATORS

  • FUNCTIONS mV, mA Resistance source mV, mA Read
  • RANGES 0 to 200 mV 0 to 25 mA 0 to 500V
  • INDICATION 4 1/2 digit LCD / LED - Green mV, mA and V or °C
  • POWER SUPPLY 230V AC, SOHz for table top model 2 Batteries of 9 VDC for portable model
  • RESOLUTION 10 uVformV 0.01 mA 0.1 V or 0.1 °C
  • ACCURACY 0.1 % of FS 0.15% of FSformA 0.2 % of FS for RTD
  • OPERATIONGTEMP & HUMIDITY 10to50°C, 90%Rhmax
  • BATTERY LIFE 6 hrs. incase of full o/p currect 30 hrs. when no o/p current 90
  • SIZE WEIGHT 90 (H) x 215 (W) x 230 (D) mm 2 kg (Table Top) 1 kg (Portable)
INTRODUCTION
Analogik universal calibrator is very useful tool to calibrate many types of process control instruments which accepts mV and mA and resistance. The universal calibrator is designed to give highest stability and accuracy. The calibrator can be used for lab or inhouse purpose as well as to used on field. This is very useful tool for calibration of instruments, commissioning, quality assurance and fault findings.
Features
Green display 1/2" height.
High accuracy & reliability.
Easy to operate.
FUNCTIONAL DESCRIPTION
Power on switch - Powers the instruments with indication.
Coarse & Fine Pot - Both the potentiometers are multiturn helipots & used to adjust the correct value on display.
Res. Adjust Pot - Mult! turn Helipot to adjust the correct value of resistance.
Read / Source Switch - Push to ON switch. When in press condition parameters will be in READ mode when unpress mV / mA in source mode.
mV / mA switch - This switch selects the parameter mV or mA either read or source.
RTD Switch - When this switch is pressed display shows temp, in C and as per resistance chart (DIN - 43760) corresponding resistance will be source when switch is relased.
When switch is in press condition output at R and B/C terminals is in open (infinity resistance) mode.
Display - Green, 1/2" height, common to read all the parameters

CALIBRATION EQUIPMENTS
mV / mA Source
RTD Simulators
mV Source
pH Simulator
Conductivity Simulator
RTD Simulator with Indication
Portable Thermocouple Calibrator
Loop Analyser

View Complete Details

2 WIRE / 4 WIRE TEMPERATURE TRANSMITTER

  • INPUT Pt-100, RTD, mV, T/C
  • OUTPUT 4-20mA in series with Power Supply
  • SUPPLY 12 to 42 VDC
  • RANGE -200 to + 600 for Pt-100 others as per requirement
  •   110 VAC, 10%50HZ
  • ACCURACY 0.25% of F. S. including linearity, repeatebility
  • TEMP. DRIFT 0.02 % °C at both end.
  • OUTPUT LOAD 600V at 24 DC supply
  • ZERO SPAN ADJUSTABILITY 15%of F. S.
  • COLD JUNCTION COMPENSATION BUILT - IN
  • THREE WIRE LEAD Up to 100V for
  • RESISTANCE COMPENSATION Pt-100, RTD, mV, T/C
  • OPERATING TEMP. 10 to 55 °C
  • OPERATING HUMIDITY 90 % Rh. N. C. max.
  • MEASURING CURRENT Lessthan 1 mA
  • OPEN SENSOR CONDITION Up scale / Down scale
  • HIGH & LOW CURRENTS ENCLOSURE 3.5mA min. 30mA max. Wall mounted type Rack mounting type Head mounted type
  • IP 55 or flame proof versions available.
  • Local indication 31/2 digit LCD available.
  • High accurancy, very low temp, drift.
  • Built - in cold junction Compensation & three wire lead resistance compensation.
  • CMRS certified explosion proof housing for Gr. II A, II B, II C.
  • Upscale / down scale for open sensor.
  • ON line easy calibration by Zero & Span.
  • GENERAL DESCRIPTION
  • Analogik 2 Wire 4W temp, transmitters accepts Pt -100 input & thermocouples & gives 4 to 20mA output proportional and linear to input signal. Direct sensor connections are eliminated, due to which long run cable for pt -100 & T/C are avoided gives economical solution. The rack mounted, G - rail, field mounting as well as pipe mounting versions are available. The flame proof version with CMRS certification for II A, B, C & E are available.In the head mounted 2W temp transmitter the sensor is attached at the bottom.
FEATURES
Three wire lead resistance compensation & built - in cold junction compensation
High accuracy typically 0.2% of F.S.
Drift free performance.
Rack mounted, field mounted, Head mounted, 2" pipe mounted, G rail versions available.
On - line calibration in case of flame proof version.

CONSTRUCTION & OPERATION
The glass epoxy, green masked, high quality components soldered PCB provides the drift free & reliable performance Low level signal mV from T/C & resistance of RTD are converted into voltage & fed to V to I converter. This further converts the signal into 4 to 20mA DC signal proportional to input. The highly stable current source & accurate reference is used to give good results. Up Scale or Down scale facilities are provided for sensor break protection.
APPLICATIONS
To avoid the signal loss & to avoid the expensive cables of the sensors the 2W - 4W transmitters is the best solution.This is used as an isolation between field operations & central room is large, the Analogik 2W - 4W transmitters is the best, economical solution
View Complete Details

PH INDICATORS / PH TRANSMITTERS

GENERAL DESCRIPTION
Analogik PH meter and transmitter incorporates the latest high technological advancements. It has very stability, reproducibility & contineous duly cycle. The instrument having very high input impedance advanced (MOS-FET butter OP-AMP) The instrument accepts all types of PH electrode. Auto / manual temp, compensation facility is available. The instrument indicates PH by 3 1/2 digit LED / LCD display.
FEATURES
Manual / Auto temp, compensation by pt-100 sensor.
Direct indication of PH/ mV and temp, by LED/LCD displays.
Slope control for correcting electrode slope.
Asymetry control to eliminate ageing offect.
0 / 4 to 20 mA output into 500 V incase of PH transmitter.
CONSTRUCTION & OPERATION
The glass epory, green masked, PCB with high quality components soldered gives the drift free performance. The mV signal from PH electrode is directly given to high I / P impedance buffer amplifier and then this signal is processed. The auto/manual temp, compensation circuit is added at this stage & signal is given to DPM / V to I connector.Thus we get PH indication or 0 / 4 to 20 mA signal proportional to input pH.
APPLICATIONS

pH meter and PH transmitter are commonly used in many industries & plants. Used in water treatment plants, Power Station, Sugar Mills, Steel Plant, Paper Industry, Chemical, Petro Chemical, Food, Fertiliser, Soft Drink Industries.

SPECIFICATIONS
pH INDICATOR
pH TRANSMITTER
RANGE
O to 14H.1999 mV
Oto14PH.
DISPLAY OUTPUT
3 1/2 digit LED or LCD
3 1/2 digit LCD-local indication optiona 0/4 to 20mA proportional to 0 to 14 PH.
ACCURACY
0.25% of F. S.
0.25% of F. S.
TEMP.Compensation Automatic with pt -100 manual by pot
Oto130C.
0 to 130 C. Automatic only.
INPUT IMPEDANCE SUPPLY
>1012Ohms.9 VDC, 230 V AC, 50 Hz 1 PHASE
>1012Ohms.9 VDC, 230 V AC, 50 Hz 1 PHASE
SLOPE ADJUSTMENT
90 to 110% at 25 C. 1
90 to 110% at 25 C. 1
ASYMETRY ADJUSTMENT
1 PH.
1 PH.
OUTPUT LOAD
-
500 V Max.
RECORDER OUTPT

View Complete Details

Portable Temperature Indicator

  • Input Pt-100, Fe-con, Cr-AI T/C.
  • INDICATION 3 1/2 digit LCD. 4 1/2 digit LCD.
  • RANGE 200to+600°C-Pt-100 0 - 600 °C - Fe - con 0-1000 °C-Cr-AI,
  • SUPPLY 9 VDC Battery Operated.
  • ACCURACY COLD JUNCTION 0.25 % of F.S.
  • COMPENSATION Built-in.
  • OPERATING TEMP & HUMIDITY 10 to 50 °C 90% Rh N. C. max.
  • SENSOR Pt-100, Fe-con, Cr-AI T/C.
  • DATA HOLD By Push Button - optional
  • POWER ON By Push Button
APPLICATIONS

Essential tool for quality control, R & D & preventative maintanance. Use to test the maximum rise of temp, of heat sink, transformers & heating Cemps in R & D.

ACCURACY COLD JUNCTION 0.25 % of F.S.
COMPENSATION Built-in.
OPERATING TEMP &HUMIDITY 10 to 50 C90% Rh N. C. max.
SENSOR Pt-100, Fe-con, Cr-AI T/C.
DATA HOLD By Push Button - optional
POWER ON By Push Button
FEATURES
3 1/2 digit or 4 1/2 digit LCD Indication.
DATA HOLD BY PUSH Button - optional.
Long battery life.
Compact size-easy to use.
Immersion, tubular, leaf, bow type sensors available.
Covers-200 to +1200 C temp, range.

9V DC Battery Operated.

View Complete Details

RS - 485 CONVERTER

  • INPUT RS - 232 (3 wire / 4 wire) / RS - 485 (2 wire) or RS 422 (4 wire)
  • Output RS - 485 (2wire) or RS -422 (4wire), RTS control it required/or RS 232
  • RS - 232 interface connector RS-485/RS-422 interface connector female 9 pin D type (DB - 9) screw terminals.
  • Baud rate 4800, 9600, 19200, 38400, 57600
  • Max. communication distance 4000 feet (1.2 km)
  • Power Supply 230 VAC, 50Hz, 1Ø or 24 VDC
  • Isolution Voltage 1500V DC
  • Operating Temp & Humidity 10to70°C95%Rh.
  • MOUNTING DIN rail mounting.
  • Dim. 70 x 60 x 110 mm
  • Weight 1/2 kg Approx.
Communication LED indicator upto 256 multidrop modules per serial port.
Transient suppressors on RS 485 communication line
RTS & CTS controlled.
On - line module insersion & removed.
Baud rate - setting not required.
View Complete Details

Level Indicators

  • INPUT CAPACITANCE TYPE.
  • OUTPUT 4 to 20 mA DC into 500 ohm.
  • INDICATION 3 1/2 digit 0.5" LED.
  • ACCURACY 2% of F.S
  • LINEARITY 2% of F.S.
  • SUPPLY VOLT AGE 230 V AC, 50 Hz Indicator
  •   24 V DC - Level XTR.
  • ZERO/SPAN By DIP Switch &
  • ADJUSTABILITY ZERO, SPAN Trimpots.
  • OPERATING TEMP. 10°T050°C.
  • HUMIDITY 90% Rh max.
  • TEMP DRIFT 0.05% / OC.
  • ENCLOSURE Al-Casted.
  • MOUNTING Panel / Head Mounting
  • WEIGHT 2 Kg Approx.
FEATURES
3 1/2, 4 1/2 digit LED / LCD indication.
Used to control the level of any liquids.
Low temp, drift.
MEASURING RANGE - Fieldselectable by DIP switch.
Calibration - easy access of ZERO, SPANpotentiometers.

APPLICATIONS
Level transmitter or level indication are used for contineous level measurement as well as level control.These are used in many industries like Petrochemicals, Water treatment plants, Food, Sugar Mills, Chemical, Coal Industries.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

List of Other Products by Analogik Electronic Corporation from Pune, Maharashtra.
Post Buy Requirement
AE

Analogik Electronic Corporation Pune, Maharashtra

Pune, Maharashtra, India
Add Review

Our Products

  1. Measuring Instruments & Equipment

    2 Products available
  2. Calibrators

    2 Products available
  3. Electrical & Electronic Testing Devices

    1 Products available
  4. Transmitter Device

    1 Products available
  5. PH Meter

    1 Products available
  6. Calibrators And Monitoring Systems

    1 Products available
  7. Decorative Lights, Lamps & Lamp Shades

    1 Products available
  8. Others Products 1 Products available

Other Products / Services #346766

We offer the best product range of thermocouple probes.

Frequency Indicators

Frequency indicators are designed to display RPM of motors. The instruments accepts the inputs directly from proximity switches, alternators or magnetic pick-up sensors. These instruments are microcontroller based to give high accuracy & easy to handle. High or Low alarm can be given if required.
View Complete Details

Thermocouple Probes

300 /Piece Get Latest Price
  • Min. Order (MOQ) 10 Piece(s)
  • Cable Type Straight
  • Probe Type Type K
  • Brand Name Analogik
View Complete Details

Universal Calibrator

Analogik universal calibrator is very useful tool to calibrate many types of process control instruments which accepts mV and mA and resistance. The universal calibrator is designed to give highest stability and accuracy. The calibrator can be used for lab or inhouse purpose as well as to used on field. This is very useful tool for calibration of instruments, commissioning, quality assurance and fault findings.
View Complete Details

UNIVERSAL CALIBRATORS AND SIMULATORS

  • FUNCTIONS mV, mA Resistance source mV, mA Read
  • RANGES 0 to 200 mV 0 to 25 mA 0 to 500V
  • INDICATION 4 1/2 digit LCD / LED - Green mV, mA and V or °C
  • POWER SUPPLY 230V AC, SOHz for table top model 2 Batteries of 9 VDC for portable model
  • RESOLUTION 10 uVformV 0.01 mA 0.1 V or 0.1 °C
  • ACCURACY 0.1 % of FS 0.15% of FSformA 0.2 % of FS for RTD
  • OPERATIONGTEMP & HUMIDITY 10to50°C, 90%Rhmax
  • BATTERY LIFE 6 hrs. incase of full o/p currect 30 hrs. when no o/p current 90
  • SIZE WEIGHT 90 (H) x 215 (W) x 230 (D) mm 2 kg (Table Top) 1 kg (Portable)
INTRODUCTION
Analogik universal calibrator is very useful tool to calibrate many types of process control instruments which accepts mV and mA and resistance. The universal calibrator is designed to give highest stability and accuracy. The calibrator can be used for lab or inhouse purpose as well as to used on field. This is very useful tool for calibration of instruments, commissioning, quality assurance and fault findings.
Features
Green display 1/2" height.
High accuracy & reliability.
Easy to operate.
FUNCTIONAL DESCRIPTION
Power on switch - Powers the instruments with indication.
Coarse & Fine Pot - Both the potentiometers are multiturn helipots & used to adjust the correct value on display.
Res. Adjust Pot - Mult! turn Helipot to adjust the correct value of resistance.
Read / Source Switch - Push to ON switch. When in press condition parameters will be in READ mode when unpress mV / mA in source mode.
mV / mA switch - This switch selects the parameter mV or mA either read or source.
RTD Switch - When this switch is pressed display shows temp, in C and as per resistance chart (DIN - 43760) corresponding resistance will be source when switch is relased.
When switch is in press condition output at R and B/C terminals is in open (infinity resistance) mode.
Display - Green, 1/2" height, common to read all the parameters

CALIBRATION EQUIPMENTS
mV / mA Source
RTD Simulators
mV Source
pH Simulator
Conductivity Simulator
RTD Simulator with Indication
Portable Thermocouple Calibrator
Loop Analyser

View Complete Details

2 WIRE / 4 WIRE TEMPERATURE TRANSMITTER

  • INPUT Pt-100, RTD, mV, T/C
  • OUTPUT 4-20mA in series with Power Supply
  • SUPPLY 12 to 42 VDC
  • RANGE -200 to + 600 for Pt-100 others as per requirement
  •   110 VAC, 10%50HZ
  • ACCURACY 0.25% of F. S. including linearity, repeatebility
  • TEMP. DRIFT 0.02 % °C at both end.
  • OUTPUT LOAD 600V at 24 DC supply
  • ZERO SPAN ADJUSTABILITY 15%of F. S.
  • COLD JUNCTION COMPENSATION BUILT - IN
  • THREE WIRE LEAD Up to 100V for
  • RESISTANCE COMPENSATION Pt-100, RTD, mV, T/C
  • OPERATING TEMP. 10 to 55 °C
  • OPERATING HUMIDITY 90 % Rh. N. C. max.
  • MEASURING CURRENT Lessthan 1 mA
  • OPEN SENSOR CONDITION Up scale / Down scale
  • HIGH & LOW CURRENTS ENCLOSURE 3.5mA min. 30mA max. Wall mounted type Rack mounting type Head mounted type
  • IP 55 or flame proof versions available.
  • Local indication 31/2 digit LCD available.
  • High accurancy, very low temp, drift.
  • Built - in cold junction Compensation & three wire lead resistance compensation.
  • CMRS certified explosion proof housing for Gr. II A, II B, II C.
  • Upscale / down scale for open sensor.
  • ON line easy calibration by Zero & Span.
  • GENERAL DESCRIPTION
  • Analogik 2 Wire 4W temp, transmitters accepts Pt -100 input & thermocouples & gives 4 to 20mA output proportional and linear to input signal. Direct sensor connections are eliminated, due to which long run cable for pt -100 & T/C are avoided gives economical solution. The rack mounted, G - rail, field mounting as well as pipe mounting versions are available. The flame proof version with CMRS certification for II A, B, C & E are available.In the head mounted 2W temp transmitter the sensor is attached at the bottom.
FEATURES
Three wire lead resistance compensation & built - in cold junction compensation
High accuracy typically 0.2% of F.S.
Drift free performance.
Rack mounted, field mounted, Head mounted, 2" pipe mounted, G rail versions available.
On - line calibration in case of flame proof version.

CONSTRUCTION & OPERATION
The glass epoxy, green masked, high quality components soldered PCB provides the drift free & reliable performance Low level signal mV from T/C & resistance of RTD are converted into voltage & fed to V to I converter. This further converts the signal into 4 to 20mA DC signal proportional to input. The highly stable current source & accurate reference is used to give good results. Up Scale or Down scale facilities are provided for sensor break protection.
APPLICATIONS
To avoid the signal loss & to avoid the expensive cables of the sensors the 2W - 4W transmitters is the best solution.This is used as an isolation between field operations & central room is large, the Analogik 2W - 4W transmitters is the best, economical solution
View Complete Details

PH INDICATORS / PH TRANSMITTERS

GENERAL DESCRIPTION
Analogik PH meter and transmitter incorporates the latest high technological advancements. It has very stability, reproducibility & contineous duly cycle. The instrument having very high input impedance advanced (MOS-FET butter OP-AMP) The instrument accepts all types of PH electrode. Auto / manual temp, compensation facility is available. The instrument indicates PH by 3 1/2 digit LED / LCD display.
FEATURES
Manual / Auto temp, compensation by pt-100 sensor.
Direct indication of PH/ mV and temp, by LED/LCD displays.
Slope control for correcting electrode slope.
Asymetry control to eliminate ageing offect.
0 / 4 to 20 mA output into 500 V incase of PH transmitter.
CONSTRUCTION & OPERATION
The glass epory, green masked, PCB with high quality components soldered gives the drift free performance. The mV signal from PH electrode is directly given to high I / P impedance buffer amplifier and then this signal is processed. The auto/manual temp, compensation circuit is added at this stage & signal is given to DPM / V to I connector.Thus we get PH indication or 0 / 4 to 20 mA signal proportional to input pH.
APPLICATIONS

pH meter and PH transmitter are commonly used in many industries & plants. Used in water treatment plants, Power Station, Sugar Mills, Steel Plant, Paper Industry, Chemical, Petro Chemical, Food, Fertiliser, Soft Drink Industries.

SPECIFICATIONS
pH INDICATOR
pH TRANSMITTER
RANGE
O to 14H.1999 mV
Oto14PH.
DISPLAY OUTPUT
3 1/2 digit LED or LCD
3 1/2 digit LCD-local indication optiona 0/4 to 20mA proportional to 0 to 14 PH.
ACCURACY
0.25% of F. S.
0.25% of F. S.
TEMP.Compensation Automatic with pt -100 manual by pot
Oto130C.
0 to 130 C. Automatic only.
INPUT IMPEDANCE SUPPLY
>1012Ohms.9 VDC, 230 V AC, 50 Hz 1 PHASE
>1012Ohms.9 VDC, 230 V AC, 50 Hz 1 PHASE
SLOPE ADJUSTMENT
90 to 110% at 25 C. 1
90 to 110% at 25 C. 1
ASYMETRY ADJUSTMENT
1 PH.
1 PH.
OUTPUT LOAD
-
500 V Max.
RECORDER OUTPT

View Complete Details

Portable Temperature Indicator

  • Input Pt-100, Fe-con, Cr-AI T/C.
  • INDICATION 3 1/2 digit LCD. 4 1/2 digit LCD.
  • RANGE 200to+600°C-Pt-100 0 - 600 °C - Fe - con 0-1000 °C-Cr-AI,
  • SUPPLY 9 VDC Battery Operated.
  • ACCURACY COLD JUNCTION 0.25 % of F.S.
  • COMPENSATION Built-in.
  • OPERATING TEMP & HUMIDITY 10 to 50 °C 90% Rh N. C. max.
  • SENSOR Pt-100, Fe-con, Cr-AI T/C.
  • DATA HOLD By Push Button - optional
  • POWER ON By Push Button
APPLICATIONS

Essential tool for quality control, R & D & preventative maintanance. Use to test the maximum rise of temp, of heat sink, transformers & heating Cemps in R & D.

ACCURACY COLD JUNCTION 0.25 % of F.S.
COMPENSATION Built-in.
OPERATING TEMP &HUMIDITY 10 to 50 C90% Rh N. C. max.
SENSOR Pt-100, Fe-con, Cr-AI T/C.
DATA HOLD By Push Button - optional
POWER ON By Push Button
FEATURES
3 1/2 digit or 4 1/2 digit LCD Indication.
DATA HOLD BY PUSH Button - optional.
Long battery life.
Compact size-easy to use.
Immersion, tubular, leaf, bow type sensors available.
Covers-200 to +1200 C temp, range.

9V DC Battery Operated.

View Complete Details

RS - 485 CONVERTER

  • INPUT RS - 232 (3 wire / 4 wire) / RS - 485 (2 wire) or RS 422 (4 wire)
  • Output RS - 485 (2wire) or RS -422 (4wire), RTS control it required/or RS 232
  • RS - 232 interface connector RS-485/RS-422 interface connector female 9 pin D type (DB - 9) screw terminals.
  • Baud rate 4800, 9600, 19200, 38400, 57600
  • Max. communication distance 4000 feet (1.2 km)
  • Power Supply 230 VAC, 50Hz, 1Ø or 24 VDC
  • Isolution Voltage 1500V DC
  • Operating Temp & Humidity 10to70°C95%Rh.
  • MOUNTING DIN rail mounting.
  • Dim. 70 x 60 x 110 mm
  • Weight 1/2 kg Approx.
Communication LED indicator upto 256 multidrop modules per serial port.
Transient suppressors on RS 485 communication line
RTS & CTS controlled.
On - line module insersion & removed.
Baud rate - setting not required.
View Complete Details

Level Indicators

  • INPUT CAPACITANCE TYPE.
  • OUTPUT 4 to 20 mA DC into 500 ohm.
  • INDICATION 3 1/2 digit 0.5" LED.
  • ACCURACY 2% of F.S
  • LINEARITY 2% of F.S.
  • SUPPLY VOLT AGE 230 V AC, 50 Hz Indicator
  •   24 V DC - Level XTR.
  • ZERO/SPAN By DIP Switch &
  • ADJUSTABILITY ZERO, SPAN Trimpots.
  • OPERATING TEMP. 10°T050°C.
  • HUMIDITY 90% Rh max.
  • TEMP DRIFT 0.05% / OC.
  • ENCLOSURE Al-Casted.
  • MOUNTING Panel / Head Mounting
  • WEIGHT 2 Kg Approx.
FEATURES
3 1/2, 4 1/2 digit LED / LCD indication.
Used to control the level of any liquids.
Low temp, drift.
MEASURING RANGE - Fieldselectable by DIP switch.
Calibration - easy access of ZERO, SPANpotentiometers.

APPLICATIONS
Level transmitter or level indication are used for contineous level measurement as well as level control.These are used in many industries like Petrochemicals, Water treatment plants, Food, Sugar Mills, Chemical, Coal Industries.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us