Post Buy Requirement

Our Products

  1. Resistors 4 Products available
  2. Electric Fittings And Components

    2 Products available
  3. Electrical Components

    2 Products available
  4. Electric Control Panels

    2 Products available
  5. Heaters, Thermostats & Heating Devices

    1 Products available
  6. Steel & Steel Products

    1 Products available
  7. Others Products 2 Products available

Other Products / Services

Our Complete range of products are ngtr panels, nis panels and lapt panels.

Ngtr Panels

Features :

  • NGTR Panel/ Cubicle encloses Neutral Grounding Transformer (NGT) and Neutral Grounding Resistor (NGR) for grounding/ earthing of Neutral current during unbalanced three phase load of the generator. This is essentially required for protection of the generator.
  • Neutral Grounding Transformer (NGT) steps down the voltage of neutral bus from 6.6 KV/ 11 KV/ 15.75 KV level to 110 Volt or 220 Volt level. This stepped down voltage is connected to a netral grounding resistance and a ground earth terminal fro bringing the voltage level of neutral bus as close as possible to zero voltage level

Manufactured using high quality raw materials, we offer theseNeutral Grounding Transformer ResistorPanels.Being processed through a number of quality checks, these products supplied by us are known for their sturdiness and durability. We are one of the leading manufacturers of these products, and we believe quality to be our priority. This product is known for the protection it provides to the generators from an unbalanced, three phase load. These products are made available in the market at very competitive prices, increasing their demand.

  • Rated Voltage :For neutral grounding or earthing resistor rated voltage means line- to neutral voltage i.e. System Voltage divided by root 3 i.e. 1.732
  • Rated Current: Means Initial current that will flow through resistor when it is cold. Normally Full load current value is same as Rated current
  • Time Rating :It is length of time for which NGR must tolerate rated voltage
  • Short Time Rating :Normally it is 10 sec. or 30 sec. or 60 sec. depending on design parameters of protection system
  • Continuous Rating :It is normally 10 % of full load current for healthy system neutral grounding resistor to be designed for continuous rating of 5 % to 10 % of full load current
  • Temperature Rise Allowed: Normally Temperature rise is restricted to 375 deg.c. above ambient temperature as per BS-587
  • Cabling or termination :Suitable arrangement and clearance is provided for termination of cable, flats or bus duct as per requirement with removable gland plate
  • Construction:NGR include resistor assembly, plus required insulators, internal connections and hardware etc
  • Material of Resistance Element:We offer resistor elements made from any stainless steel or Cu-Ni or Ni-Cr or any other resistance material as per requirement. Normally formed stainless steel element are best and economical for NGRS
View Complete Details

Lapt Panel Boards

  • Voltage 110V
  • Country of Origin India

Features : WE HAVE EMERGED AS ONE OF THE TRUSTED ORGANIZATION ENGAGED IN FABRICATING LAPT PANEL BOARDS TO THE CUSTOMERS. OUR RANGE IS WIDELY APPRECIATED BY THE CLIENTS FOR ITS EFFICIENT FUNCTIONING AND APPLICATION IN VARIED INDUSTRIES & SECTORS. MOREOVER, WE CONSIDER THE MARKET DEMAND WHILE FABRICATING THESE PANELS. FOLLOWING ARE THE FEATURES OF THESE PRODUCTS :Shock-proof exteriorsSturdy constructionReliable performance

An LAVT panel is a cubicle which houses a Lightning Arrester (Surge Arrester), Surge Capacitor, and Voltage / Potential Transformers for a Phase Isolated Bus Duct.Lightning arrestor is there to provide protection against any surges in voltage, hence the name lightning arrestor, it is a device that safely diverts any surge in voltage "away" from your plant therefore protecting your equipment against overvoltage conditions.A capacitor is connected in parallel with the lightning arrester for enhanced protection as well.

The voltage transformer will probably be for either protection purposes or for some instruments on your system.If you have a voltmeter or wattmeter etc on the panel then it is probable that it's supply is derived from the VT. A VT transforms the primary voltage, in this case 11kV down to a low voltage (probably 110V) to give an accurate representation of the system volts, which can be incorporated into protection devices and measuring devices.LAVT Panels are used in all high voltage power Plants wherein for protection of the Alternator. This unit is phase isolated and is mostly connected to the bus duct.

View Complete Details

Nis Panels

manufacturer & exporter of nis panels & neutral isolator panels. Our product range also comprises of load banks, starting resistors and braking resistors.

features :

in electric braking, traction motor acts as a generator. Kinetic energy of a moving train converted into electrical energy is, dissipated in the form of heat. This is called dynamic braking. construction : dynamic braking resistors are manufactured as per customers requirement. testing : all routine tests are conducted in-house.

following special tests are also conducted if required:

vibration testrain testhygroscopic test.isolatorsht indoor isolators of following rating3.3 kv / 6.6 kv/ 12 kv / 22 kv / 33 kv. 400 amp./630 amp./1200 amp./1800 amp./3200 amp.

owing to the high level of performance and sturdy construction, theseneutral isolator panelsmanufactured and supplied by us are one of the highly preferred products in the market. This product is one of the most common, reliable, economical, and efficient solutions for earthing. This product is manufactured using high quality raw materials and modern machinery, under the supervision of trained and experienced professionals. Quality being our priority, we send all our products through a number of quality checks.

testing :

  • all routine tests are conducted in-house

following special tests are also conducted if required :

  • vibration test
  • rain test
  • hygroscopic test
View Complete Details

Electrical Heaters

Manufacturer & Exporter of Electrical Heaters. Our product range also comprises of Load Banks, Starting Resistors and Braking Resistors.

Features :

  • The comprehensive range of electric heaters offered by us is manufactured in compliance with the international quality standards
We are one of the most well known manufacturers and suppliers of theseElectrical Heaters.Manufactured in accordance to international standards and norms, the production process involves using of high quality raw materials and processing the end products through a number of quality checks. These products are known for the efficient heating it provides. This product is highly demanded in the market owing to its high quality and low pricing.

Detail :

  • No Thermostat required, virtually unlimited life, it can control the temperature by itself
  • safety due to automatic temperature control
  • it depends on PTC elements as its heating resources
  • Doesn't burn when in contact with paper, matches or clothes
  • No moving parts to wear, Very low cost
  • No electrical noise, the higher temperature, the more electricity efficient
  • Low electricity consumption, efficient heat retaining
View Complete Details

Load Banks

  • Power ratings available 1KW / 2KW / 5 KW / 10KW
  • Voltage Primary 440V AC 3Phase/ 220V AC

Voltage utilized in industry are of either resistive, inductive or capacitive types these provide various types of power factor and the power system behaves accordingly. Resistive load banks are used to provide braking effect or for heat dissipation. These have canthel wires wounded on porcelain tubes through which electricity is passed & current flows, normally for resistive loads the power factor is unity. This model is the industrialeducational model suitable for demonstrating to students the complete know of the basics, loading provided in steps, study of efficiency & maintenance of these loads packaged in small rating. Students can make connections of their own with the help of the terminations provided

View Complete Details

Load Banks For Industrial Automation

We are engaged in offering ofLoad Banks for Industrial Automation.Known for its compact structure and high level of efficiency, Load Banks are highly appreciated in the market.

What Is Load Bank :
  • Load banks are compact units that are coupled to the output of your power generation system such as diesel generators, gas turbines or UPS and battery systems
  • Load banks are dummy loads, designed to simulate the plant load and prove the design, performance and the capacity of the system, without interruption to the normal running of your plant

WHAT DOES A LOAD BANK DO :

Generators are usually rated to supply sufficient power to a plant or building, based on the maximum demand required. Sufficient plant loading is not always available to safely load generators. Under loading of the engine will cause a high wear rate due to insufficient fuel combustion and loss of lubrication resulting in cylinder bore glazing and fouling of exhaust ports and valves. Running the generator without load will not prove its performance or power capacity.

Proper and controlled loading is therefore essential. It increases diesel engine life by up to four times and improves the efficiency by ensuring that the engine has sufficient loading at all times.

It proves the rated power, proves system operation, controls integrity and communications of your power system. It maximize battery life in UPS systems by regular loading and discharging.

Specifications :

  • Power ratings available : 1KW / 2KW / 5 KW / 10KW
  • Voltage Primary : 440V AC 3Phase/ 220V AC Single phase /220V DC
  • Enclosed in cabinet with Steps provided for loading, meters provided for each phase & terminations brought out on Banana terminals
View Complete Details

Steel Neutral Isolator Panels

We are engaged in offering ofNeutral Isolator Panels for Steel Industries.Quality being our priority, we send all our products through a number of quality checks.

Features:
  • Vibration Test
  • Rain Test
  • Hygroscopic Test

HT indoor isolators of following rating

  • 3.3 KV / 6.6 KV/ 12 KV / 22 KV / 33 KV
  • 400 Amp./630 Amp./1200 Amp./1800 Amp./3200 Amp
View Complete Details

LAVT Panels For Hydro Power Industries

We are offering a wide range of LAVT Panels for Hydro Power Industries. With its shock proof body and strong built, theseLAVT Panelsmanufactured and supplied by us are known for the long operational life. Advantages of using :

  • Installation of NGR in the system reduces mechanical stresses in circuits and equipment subjected to fault currents. This also reduces the electrical-shock hazards to personnel caused by stray ground fault currents in the ground return path
  • Reduction in the momentary line-voltage dip occasioned by the occurrence and clearing of a ground fault
  • To secure control of transient over-voltages while at the same time avoiding the shutdown of a facility circuit on the occurrence of the first ground fault
  • Installation of NGR protects critical and expensive equipment such as Transformers and Generators from damage due to earth faults

Specifications :

  • Power Rate: 11 KV Upto 24 KV system
  • Materiel - Surge Capacitor, Surge Arrester Voltage Stroke Potential transfer
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

List of Other Products by Ampcontrol Equipments Pvt. Ltd. from Pune, Maharashtra.
Post Buy Requirement

Our Products

  1. Resistors 4 Products available
  2. Electric Fittings And Components

    2 Products available
  3. Electrical Components

    2 Products available
  4. Electric Control Panels

    2 Products available
  5. Heaters, Thermostats & Heating Devices

    1 Products available
  6. Steel & Steel Products

    1 Products available
  7. Others Products 2 Products available

Our Products

Our product range contains a wide range of ngtr panels, nis panels and lapt panels

Ngtr Panels

Features :

  • NGTR Panel/ Cubicle encloses Neutral Grounding Transformer (NGT) and Neutral Grounding Resistor (NGR) for grounding/ earthing of Neutral current during unbalanced three phase load of the generator. This is essentially required for protection of the generator.
  • Neutral Grounding Transformer (NGT) steps down the voltage of neutral bus from 6.6 KV/ 11 KV/ 15.75 KV level to 110 Volt or 220 Volt level. This stepped down voltage is connected to a netral grounding resistance and a ground earth terminal fro bringing the voltage level of neutral bus as close as possible to zero voltage level

Manufactured using high quality raw materials, we offer theseNeutral Grounding Transformer ResistorPanels.Being processed through a number of quality checks, these products supplied by us are known for their sturdiness and durability. We are one of the leading manufacturers of these products, and we believe quality to be our priority. This product is known for the protection it provides to the generators from an unbalanced, three phase load. These products are made available in the market at very competitive prices, increasing their demand.

  • Rated Voltage :For neutral grounding or earthing resistor rated voltage means line- to neutral voltage i.e. System Voltage divided by root 3 i.e. 1.732
  • Rated Current: Means Initial current that will flow through resistor when it is cold. Normally Full load current value is same as Rated current
  • Time Rating :It is length of time for which NGR must tolerate rated voltage
  • Short Time Rating :Normally it is 10 sec. or 30 sec. or 60 sec. depending on design parameters of protection system
  • Continuous Rating :It is normally 10 % of full load current for healthy system neutral grounding resistor to be designed for continuous rating of 5 % to 10 % of full load current
  • Temperature Rise Allowed: Normally Temperature rise is restricted to 375 deg.c. above ambient temperature as per BS-587
  • Cabling or termination :Suitable arrangement and clearance is provided for termination of cable, flats or bus duct as per requirement with removable gland plate
  • Construction:NGR include resistor assembly, plus required insulators, internal connections and hardware etc
  • Material of Resistance Element:We offer resistor elements made from any stainless steel or Cu-Ni or Ni-Cr or any other resistance material as per requirement. Normally formed stainless steel element are best and economical for NGRS
View Complete Details

Lapt Panel Boards

  • Voltage 110V
  • Country of Origin India

Features : WE HAVE EMERGED AS ONE OF THE TRUSTED ORGANIZATION ENGAGED IN FABRICATING LAPT PANEL BOARDS TO THE CUSTOMERS. OUR RANGE IS WIDELY APPRECIATED BY THE CLIENTS FOR ITS EFFICIENT FUNCTIONING AND APPLICATION IN VARIED INDUSTRIES & SECTORS. MOREOVER, WE CONSIDER THE MARKET DEMAND WHILE FABRICATING THESE PANELS. FOLLOWING ARE THE FEATURES OF THESE PRODUCTS :Shock-proof exteriorsSturdy constructionReliable performance

An LAVT panel is a cubicle which houses a Lightning Arrester (Surge Arrester), Surge Capacitor, and Voltage / Potential Transformers for a Phase Isolated Bus Duct.Lightning arrestor is there to provide protection against any surges in voltage, hence the name lightning arrestor, it is a device that safely diverts any surge in voltage "away" from your plant therefore protecting your equipment against overvoltage conditions.A capacitor is connected in parallel with the lightning arrester for enhanced protection as well.

The voltage transformer will probably be for either protection purposes or for some instruments on your system.If you have a voltmeter or wattmeter etc on the panel then it is probable that it's supply is derived from the VT. A VT transforms the primary voltage, in this case 11kV down to a low voltage (probably 110V) to give an accurate representation of the system volts, which can be incorporated into protection devices and measuring devices.LAVT Panels are used in all high voltage power Plants wherein for protection of the Alternator. This unit is phase isolated and is mostly connected to the bus duct.

View Complete Details

Nis Panels

manufacturer & exporter of nis panels & neutral isolator panels. Our product range also comprises of load banks, starting resistors and braking resistors.

features :

in electric braking, traction motor acts as a generator. Kinetic energy of a moving train converted into electrical energy is, dissipated in the form of heat. This is called dynamic braking. construction : dynamic braking resistors are manufactured as per customers requirement. testing : all routine tests are conducted in-house.

following special tests are also conducted if required:

vibration testrain testhygroscopic test.isolatorsht indoor isolators of following rating3.3 kv / 6.6 kv/ 12 kv / 22 kv / 33 kv. 400 amp./630 amp./1200 amp./1800 amp./3200 amp.

owing to the high level of performance and sturdy construction, theseneutral isolator panelsmanufactured and supplied by us are one of the highly preferred products in the market. This product is one of the most common, reliable, economical, and efficient solutions for earthing. This product is manufactured using high quality raw materials and modern machinery, under the supervision of trained and experienced professionals. Quality being our priority, we send all our products through a number of quality checks.

testing :

  • all routine tests are conducted in-house

following special tests are also conducted if required :

  • vibration test
  • rain test
  • hygroscopic test
View Complete Details

Electrical Heaters

Manufacturer & Exporter of Electrical Heaters. Our product range also comprises of Load Banks, Starting Resistors and Braking Resistors.

Features :

  • The comprehensive range of electric heaters offered by us is manufactured in compliance with the international quality standards
We are one of the most well known manufacturers and suppliers of theseElectrical Heaters.Manufactured in accordance to international standards and norms, the production process involves using of high quality raw materials and processing the end products through a number of quality checks. These products are known for the efficient heating it provides. This product is highly demanded in the market owing to its high quality and low pricing.

Detail :

  • No Thermostat required, virtually unlimited life, it can control the temperature by itself
  • safety due to automatic temperature control
  • it depends on PTC elements as its heating resources
  • Doesn't burn when in contact with paper, matches or clothes
  • No moving parts to wear, Very low cost
  • No electrical noise, the higher temperature, the more electricity efficient
  • Low electricity consumption, efficient heat retaining
View Complete Details

Load Banks

  • Power ratings available 1KW / 2KW / 5 KW / 10KW
  • Voltage Primary 440V AC 3Phase/ 220V AC

Voltage utilized in industry are of either resistive, inductive or capacitive types these provide various types of power factor and the power system behaves accordingly. Resistive load banks are used to provide braking effect or for heat dissipation. These have canthel wires wounded on porcelain tubes through which electricity is passed & current flows, normally for resistive loads the power factor is unity. This model is the industrialeducational model suitable for demonstrating to students the complete know of the basics, loading provided in steps, study of efficiency & maintenance of these loads packaged in small rating. Students can make connections of their own with the help of the terminations provided

View Complete Details

Load Banks For Industrial Automation

We are engaged in offering ofLoad Banks for Industrial Automation.Known for its compact structure and high level of efficiency, Load Banks are highly appreciated in the market.

What Is Load Bank :
  • Load banks are compact units that are coupled to the output of your power generation system such as diesel generators, gas turbines or UPS and battery systems
  • Load banks are dummy loads, designed to simulate the plant load and prove the design, performance and the capacity of the system, without interruption to the normal running of your plant

WHAT DOES A LOAD BANK DO :

Generators are usually rated to supply sufficient power to a plant or building, based on the maximum demand required. Sufficient plant loading is not always available to safely load generators. Under loading of the engine will cause a high wear rate due to insufficient fuel combustion and loss of lubrication resulting in cylinder bore glazing and fouling of exhaust ports and valves. Running the generator without load will not prove its performance or power capacity.

Proper and controlled loading is therefore essential. It increases diesel engine life by up to four times and improves the efficiency by ensuring that the engine has sufficient loading at all times.

It proves the rated power, proves system operation, controls integrity and communications of your power system. It maximize battery life in UPS systems by regular loading and discharging.

Specifications :

  • Power ratings available : 1KW / 2KW / 5 KW / 10KW
  • Voltage Primary : 440V AC 3Phase/ 220V AC Single phase /220V DC
  • Enclosed in cabinet with Steps provided for loading, meters provided for each phase & terminations brought out on Banana terminals
View Complete Details

Steel Neutral Isolator Panels

We are engaged in offering ofNeutral Isolator Panels for Steel Industries.Quality being our priority, we send all our products through a number of quality checks.

Features:
  • Vibration Test
  • Rain Test
  • Hygroscopic Test

HT indoor isolators of following rating

  • 3.3 KV / 6.6 KV/ 12 KV / 22 KV / 33 KV
  • 400 Amp./630 Amp./1200 Amp./1800 Amp./3200 Amp
View Complete Details

LAVT Panels For Hydro Power Industries

We are offering a wide range of LAVT Panels for Hydro Power Industries. With its shock proof body and strong built, theseLAVT Panelsmanufactured and supplied by us are known for the long operational life. Advantages of using :

  • Installation of NGR in the system reduces mechanical stresses in circuits and equipment subjected to fault currents. This also reduces the electrical-shock hazards to personnel caused by stray ground fault currents in the ground return path
  • Reduction in the momentary line-voltage dip occasioned by the occurrence and clearing of a ground fault
  • To secure control of transient over-voltages while at the same time avoiding the shutdown of a facility circuit on the occurrence of the first ground fault
  • Installation of NGR protects critical and expensive equipment such as Transformers and Generators from damage due to earth faults

Specifications :

  • Power Rate: 11 KV Upto 24 KV system
  • Materiel - Surge Capacitor, Surge Arrester Voltage Stroke Potential transfer
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us