clients can avail from us, highly efficient 3 pass liquid phase thermic fluid heater . Our 3 pass liquid phase thermic fluid heater is a compact, rigid, noiseless & fully automatic hot air heater / furnace. These 3 pass liquid phase thermic fluid heaters have user- friendly features and are very easy to operate. our 3 pass liquid phase thermic fluid heaters operate automatically on pre set temperature. applications chemicals : reaction kettles, evaporators, distillation columns, tray dryers textile : polymerizers, curing machines stenters, winches, dryers etc plastic & rubber : bounding and curing vulcanizing-heating for extrusion presses impregnation process moulding and laminating pressing timber : veneering presses plywood manufacture and timber drying metal finishing : heating plating picking anodising and photphating bates, drying ovens degreasing plants food industry: refining process, fruit & vegetable canning, dehydration packaging : rotogravure, flexography, metallsing etc rubber : hydraulic presses chambers confectionery : dryers, mixers miscellaneous : insulation drying sealing batteries, perfume manufacture and printing ink drying, heating of bulk storage tanks, bitumen heating spaces heating besides the above, thermic fluid heater can also be used for a number of other applications designed and constructionil burner & electricals the internal combustion chamber is used to accommodate concentric helical tube machine wound coil, (fabricated out of erw) boiler tube as bs 3059) this coil is placed in a double shell of mild steel construction. This of design helps in economizing the space and simultaneously ensures optimum rate of heat release due to elimination of extensive use of refractory, it permits rapit start up and operational and maintenance flexibility. combustion a fuel automising pressure - jet burner fitted with fuel oil nozzle from "monarch" (usa) is placed vertically download for combustion a drynamically balanced blower fan pushes combustion air through the annular space between the inner and outer shell where air is pre-heated for efficient combustion and higher efficiency the air acts as an effective thermal insulator eliminating the need for conventional insulation near the tip of burner air is swirled through astainless steel diffuser plate and mixes with automised fuel which achieve total combustion in the furnace. burner and fuel system from fuel tank the oil goes to a fuel filter then into a fuel pump through the fuel pump it is passed into an electrically heated oil pre-heating tank (this is in case of l.d.o) and them forced to burner the thermic fluid heater is supplied with pressure-jet burner of highly compact rugged and simple design the burner is fully automatic in operation and switches on and off as per the process heat requirements. no steam - no indian boiler regulations the amco therm is outside the purview of indian boiler regulations since no steam is generated no statutory inspections are required eliminating the need for a shut-down of the process there is no need for a separate boiler houses or even a qualified boiler attendant. no corrosion no scale formation the heat transfer fluids used in the anco therm thermic fluids heater are of mineral origin and do not contain any dissolved solids which cause corrosion of scale formation which is prevalent in case of steam boiler because of this thermal efficiency remains uniformly high, and this is sustained over a long period. instrumentation control and safeties amco therm is a fully automatic thermic fluid heater fitted with safety devices like high fluid temperature switch pressure switch low level switch in expansion tank spring loaded safety valve high stack temperature switch, flame sensor low fuel oil temperature switch and circulating pump motor interlock. The unblended operation is possible due to efficient design and highly reliable instruments from manufacturers like : landis & gyr (germany) monarch (usa) danfoss (denmark), larsen & slemen , ngef, crompton, kirioskar saizer, finolex, bells, indfoss , tata/ti, toubro, k.s.b -auro etc. Adust proof pre wired control panel housing mcbs, overload relay , contractors safety alarms, temperature controllers, temperature indicator and sequence controller has audio-visual alarms for abnormal working conditions. after sales services each thermic fluid heater is rigidly tested before delivery and commissioned by our trained engineers we have efficientand attentive after-sale-services network including servicing and supply of spare parts. All our general spares are readily available with us and local market also. technical specifications detailsmodelat – 0.5at – 01at-0.2at-04at-06at-10at-15heat output kcal/hrs500001, 00, 0002, 00, 0004, 00, 0006, 00, 00010, 00, 00015, 00, 000fuel consumption (approx.)l.d.okg/hrs5.711.422.945.768.6114.4171.6h.s.d.5.611.2522.54567.6112.7169.1thermal efficiency87% + 1% on nett calorific value (ncv)electrical supply415 + 6% 560 hz + 3%, ac – 3 phase, 4 wirecirculating pump motorhp2.05.07.512.515.020.025.0kw1.53.75.59.411.2515.018.8fuel pump motorhp♦♦♦♦0.51.01.0burner motorhp0.51.02.03.05.010.015.0kw0.370.751.52.23.73.711.0burner controlon – off0-50% on-off 60 – 100% low high0-33% on-off 33-100% mcoulationtotal connected loadkw2.05.08.012.015.023.030.75dry height (approx.)kg75093013001350300036004100overall dimensions (meters)length1.21.501.591.852.142.403.0width0.790.841.031.831.902.302.50height0.792.102.262.803.263.504.30 note fuel oil consumption is based on nett calorific value of (hsd)10200 kcal/kg ldo 10050 kcal/kg we reserve the right to change any specification without prior notice