Post Buy Requirement

Boilers

We are leaders in the market for providing best range of High Pressure FBC Boiler, fbc boiler, Gas Smoke Tube Package Boiler, Gas Smoke Tube Package and Smoke tube Package Steam Boiler

High Pressure FBC Boiler

we offer high pressure fbc boiler. features : boiler india built-in super heater boiler india choice of fuel feeding systems - in bed for coal, lignite, saw dust. - over bed for rice husk. boiler india bio gas compatible boiler india microprocessor controlled fuel feeder water cooled, suvega tube water wall. boiler india packaged concept, minimum welding at installation site. boiler india no expansion of tubesFeatures :

Built-in Super heater boiler India Choice of Fuel Feeding Systems - In

Bed for Coal, Lignite, Saw Dust. - Over Bed for Rice Husk.

Bio Gas Compatible

Microprocessor Controlled Fuel Feeder Water cooled, Suvega Tube Water wall.

Packaged Concept, Minimum welding at Installation site.

No Expansion of tubes

View Complete Details

Fbc Boiler

Built-in Super heater, Choice of Fuel Feeding Systems - In Bed for Coal, Lignite, Saw Dust. - Over Bed for Rice Husk. Bio Gas Compatible, Microprocessor Controlled Fuel Feeder Water cooled, Suvega Tube Water wall. Packaged Concept, Minimum welding at Installation site. No Expansion of tubes

View Complete Details

Gas Smoke Tube Package Boiler

  • Capacity 500 kg/hr to 15, 000 kg/hr
  • Fuel L.D.O., F.O., H.S.D., Natural Gas or any special liquid

manufacturingunder internationally accepted inspection agencies i.e. Ibr, lloyd's, sgs, bureau veritas, tuv, or any others as per client's demand

  • higher capacity boilers are available on request.
  • ldo gross calorific value - 10079 kcal/kg.
  • fo gross calorific value - 9600 kcal/kg.

Model Unit AB-10 AB-15 AB-20 AB-30 AB-40 AB-50 AB-60 AB-70 AB-80 AB-90 AB-100
Evaporation F & A 100 o C Kgs/Hr 1000 1500 2000 3000 4000 5000 6000 7000 8000 9000 10000
Rating M2 33 48 65 95 125 155 190 220 250 280 312
Working Press Kgs/cm2 10.54 Kgs/cm2 to 21.09 Kgs/cm2
Eff. On NCV % 92 ± 2
Fuel Consum. LDO Kgs/Hr 60 90 120 180 240 300 360 420 480 540 600
FO Kgs/Hr 63 94.5 126 189 252 315 378 441 504 567 630
Design code   IBR-1950 or ISO/R-831
Electric Supply   415 Volts, 50Hz, 3p. 4 Wire
Feed pump KW 3.75 3.75 5.00 5.00 5.00 7.50 10.5 10.5 10.5 10.5 10.5
Blower motor KW 2.25 3.75 3.75 5.00 7.50 10.50 10.50 15.0 18.75 18.75 18.75
Fuel preheater KW 6.0 9.0 9.0 12.0 15.0 18.0 18.0 18.0 18.0 18.0 18.0
Fuel pump KW 0.50 0.75 0.75 0.75 0.75 0.75 1.5 1.5 1.5 1.5 1.5
  • Higher capacity Boilers are available on request.
  • LDO Gross Calorific Value - 10079 Kcal/Kg.
  • FO Gross Calorific Value - 9600 Kcal/Kg.


 

Usefull Links

Our Expertise in

  • Steam Boiler
  • Reverse Flow Steam Boiler
  • Oil/Gas Smoke Tube Package
  • Solid Fuel Steam Boiler
  • Thermic Fluid Heater
  • Solid Fuel Fired - Thermic Fluid Heater
  • Oil/Gas - Thermic Fluid Heater
  • Hot Water Generator
  • Solid Fuel Hot Water Generator
  • Heat Exchanger

Browse

  • Home
  • About Company
  • Our Products
  • Our Clients
  • Vision - Mission
  • Download Area
  • Contact us
  • Inquiry now
  • Sitemap
  • Blog and Articles

Usefull Tags

  • Steam boiler
  • boiler
  • Coal Fired Steam boiler
  • Oil Fired Thermic Fluid Heater
  • Hot Water Generator
  • power plant boiler
  • Thermic Fluid heater
  • I.B.R.Steam boiler
  • Oil Fired Steam boiler
  • Gas Fired Steam boiler

Contact us

31, Panchratna Ind Estate, Opp : Ramol 
Police Chowky, Nr, Express Highwy 
Over bridge Phas- 4 G.I.D.C. Vatva-45 
Ahmedabad, Gujarat india

Phone : + 91 79 40084781 
Mobile : + 91-9824343561

Email : info@ambicaboilers.com 
              sales@ambicaboilers.com

Website : www.ambicaboilers.com

  •  
  •  
  •  
  •  

   







View Complete Details

Gas Smoke Tube Package

  • Evaporation F & A 100 o C Kgs/Hr
  • 1000 1500
  • 2000 3000
  • 4000 5000
  • 6000 7000
  • 8000 9000
  • 10000 Rating
  • M2 33
  • 48 65
  • 95 125
  • 155 190
  • 220 250
  • 280 312
  • Working Press Kgs/cm2
  • 10.54 Kgs/cm2 to 21.09 Kgs/cm2 Eff. On NCV
  • % 92 ± 2
  • Fuel Consum. LDO
  • Kgs/Hr 60
  • 90 120
  • 180 240
  • 300 360
  • 420 480
  • 540 600
  • FO Kgs/Hr
  • 63 94.5
  • 126 189
  • 252 315
  • 378 441
  • 504 567
  • 630 Design code
  •   IBR-1950 or ISO/R-831
  • Electric Supply  
  • 415 Volts, 50Hz, 3p. 4 Wire Feed pump
  • KW 3.75
  • 3.75 5.00
  • 5.00 5.00
  • 7.50 10.5
  • 10.5 10.5
  • Blower motor KW
  • 2.25 3.75
  • 7.50 10.50
  • 10.50 15.0
  • 18.75 18.75
  • 18.75 Fuel preheater
  • KW 6.0
  • 9.0 9.0
  • 12.0 15.0
  • 18.0 18.0
  • Fuel pump KW
  • 0.50 0.75
  • 0.75 0.75
  • 1.5 1.5

Capacity :500 kg/hr to 15, 000 kg/hr

Fuel :L.D.O., F.O., H.S.D., Natural Gas or any special liquid or ga

Manufacturingunder Internationally accepted Inspection Agencies i.e. IBR, Lloyd's, SGS, Bureau Veritas, TUV, or any others as per client's demand

  • Higher capacity Boilers are available on request.
  • LDO Gross Calorific Value - 10079 Kcal/Kg.
  • FO Gross Calorific Value - 9600 Kcal/Kg.
View Complete Details

Smoke Tube Package Steam Boiler

we offer steam boiler higher ratings boiler are available on request. steam boiler coal gross calorific value 4500 kcalkg. steaHigher ratings boiler are available on request

Coal gross calorific Value 4500 Kcal/kg.

Lignite gross calorific Value 3500 Kca/kg.m boiler lignite gross calorific value 3500 kcakg.

MODEL UNITE ABSH-05 ABSH-10 ABSH-15 ABSH-20 ABSH-25 ABSH-30 ABSH-40 ABSH-50 ABSH-60
Evaporation F&A 100 °C Kgs/Hr. 500 1000 1500 2000 2500 3000 4000 5000 6000
Rating 23 63 85 85 105 125 172 210 250
Working pressure Kg/Cm² 10.54Kg/Cm² to 21.09 Kg/Cm²
Thermal Efficiency % 76 ± 2%
Fuel Consumption Kgs/Hr 80 160 240 320 400 480 640 800 960
Design Code IBR-1950 WITH LATEST AMMEDMENT OR ISO/R-831
Electric Supply 415 Volts, , 50 Hz, 3 Phase, Neutral.
Feed Pump H.P. 3 H.P. 
X 2 no.
5 H.P. 
X 2 No.
7.5 H.P. 
X 2 No
7.5 H.P. 
X 2 No
10 H.P. 
X 2 No
10 H.P. 
X 2 No
10 H.P. 
X 2 No
12.5 H.P. 
X 2 NO
15 H.P. 
X 2 No.
I.D.Fan H.P. 3 H.P. 5 H.P. 7.5 H.P. 12.5 H.P. 12.5H.P. 15 H.P. 15 H.P. 25 H.P. 30 H.P.









MODEL UNITE ABSH-05 ABSH-10 ABSH-15 ABSH-20 ABSH-25 ABSH-30 ABSH-40 ABSH-50 ABSH-60
Evaporation F&A 100 °C Kgs/Hr. 500 1000 1500 2000 2500 3000 4000 5000 6000
Rating 23 63 85 85 105 125 172 210 250
Working pressure Kg/Cm² 10.54Kg/Cm² to 21.09 Kg/Cm²
Thermal Efficiency % 76 ± 2%
Fuel Consumption Kgs/Hr 80 160 240 320 400 480 640 800 960
Design Code IBR-1950 WITH LATEST AMMEDMENT OR ISO/R-831
Electric Supply 415 Volts, , 50 Hz, 3 Phase, Neutral.
Feed Pump H.P. 3 H.P. 
X 2 no.
5 H.P. 
X 2 No.
7.5 H.P. 
X 2 No
7.5 H.P. 
X 2 No
10 H.P. 
X 2 No
10 H.P. 
X 2 No
10 H.P. 
X 2 No
12.5 H.P. 
X 2 NO
15 H.P. 
X 2 No.
I.D.Fan H.P. 3 H.P. 5 H.P. 7.5 H.P. 12.5 H.P. 12.5H.P. 15 H.P. 15 H.P. 25 H.P. 30 H.P.









View Complete Details

Husk Fired Boiler

  • Coal gross calorific Value 4500 Kcal/kg

Smoke tube Package Steam Boiler (Horizontal Steam Boiler), Higher ratings boiler are available on request. Coal gross calorific Value 4500 Kcalkg. Lignite gross calorific Value 3500 Kcakg.

View Complete Details

Reverse Flow Steam Boiler

We offer reverse flow steam boiler. Parameter unit asv-02 asv-03 asv-04 asv-05 asv-06 asv-08 operating data steam output (f&a 100*c) kghr 200 300 400 500 600 800 steam pressure kgcm 10.54 or 15

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us