Our Product / Services
ALPHA CHEM- 1025 Advance Projection Microscope
This Microscope is very useful for routine observation and complex type measurements of specimen magnified on screen, group observations, discussions and teaching.
Specifications:-
Equipped with a 195 mm diameter
Special material graduated screen
Built-in base illuminator & diaphragm which is directed to the condenser which again is reflected through a mirror to the objective and compensating eyepiece for projection on to the screen again by a reflector
Graduated Mechanical stage is also provided on the large stage for backward and forward movements within 30mm& 40mm scales read by verniers to 0.1mm
Screen-head is rotatable through 360o with cross scales vertically and horizontally within 140mm
A quadruple nose-piece carries has four objectives : 5X, 10X, 20X & 40X giving magnification from 125X to 1000X.
A: Magnification from 125X to 1500X.
B : Incorporated with Binocular Head.
C : Screen of 150 mm diameter.
ALPHA CHEM- 1009 Binocular Pathological Research Microscope Phase Contrast and digital PID Bio-Thermal hot plate is one of the best microscope for viewing transparent or translucent specimens without a loss of resolution. This technique has proven to be a valuable tool for medical researchers in the study of living cells, cultures and many applications. The PROPORTIONAL INTEGRAL DERIVATIVE CONTROLLER (PID controller) is a generic control loop feedback mechanism (controller) which is widely used in medical control systems. This device is mainly used in Animal husbandry, various governmental & private Semen banks. This device is used to retain the plate at a proper temperature to check the live semens under the phase contrast light.
SPECIFICATIONS
Optical System : Plan / Achromat optical system.
Magnification : 100x-1000x for visual observation.
Eyepiece tubes : Binocular tube, Sidentopf type ( 30, IP distance 55-75mm, 360 rotatable).
Eyepieces : WF 10x (F.O.V. 20mm) & Centering telescopic eye-piece.
Nosepiece : Quadruple nosepiece, reversed type.
Stage : Rectangular142x 120 mm surface stage mounted on the main body cross travel 130x50mm using low-positioned X/Y coaxial control knob.
Objectives : Plan / Achromat10x N.A.0.25, 20x N.A.0.4, 40x N.A.0.65, 100x N.A.1.25
Condenser : Phase contrast condenser, Annular diaphragm turn plate.
Illumination : 3W LED lighting system with brightness controller.
Filters" : Frosted White Filter & Green Filter
Digital PID Bio-Thermal Hot Plate:
Control Action : PID Reverse Action
Input : K type thermocouple
Output : Relay Output
Alarm : 1 deviation High alarm (AL1)
Temperature Range : Room Temperature 100 Celsius with auto cut facility."
ALPHA CHEM- 1008 Binocular Microscope
Binocular Microscope : Specifications of body as above but provided with Binocular observation head inclined at 45 rotatable through 360 and with inter-pupillary adjustment.
With Hygenian eye-pieces 10X, 15X (Paired) Achromatic
Objectives : 5X, 10X, 45X & 100X - oil immersion (spring loaded) detachable mechanical stage
Magnification : 50X to 1500X