1 Products availableWe offer the best product range of 100 LPH / MS DLX RO Water Plant, 250 LPH / MS DLX RO Water Plant, 500 LPH / MS DLX RO Water Plant, 1000 LPH RO Water Plant and Ro Plant.
PLANT INTRODUCTION This produces quality water at the flow rate of 100 litres per hour. It can work continuously for 8 to 9 hours per day besides 0.5 hour to 1 hour for back-washing of the filtration system. RAW WATER ANALYSIS This water treatment system is based on the following water analysis:
RAW WATER ANALYSIS
Sl. No. | Parameter | Analysis Value |
---|---|---|
1 | Total Dissolved Solids (TDS) | 2000ppm |
2 | Turbidity | 1 NTU |
3 | SDI | 4 |
4 | Heavy Metals | NIL |
5 | Organics And Bacteria | NIL |
6 | Oil And Grease | NIL |
7 | Residual Chlorine | NIL |
8 | Temperature | < 40˚C |
9 | Color | Colorless |
10 | Odour | Very Less Odour |
11 | BOD & COD | NIL |
12 | Total Hardness | 850 PPM |
END WATER QUALITY
Sl. No. | Parameter | Analysis Value |
---|---|---|
1 | Total Dissolved Solids (TDS) | < 100ppm |
2 | PH | 7.0 ± 0.2 |
3 | Turbidity | NIL |
4 | Color | NIL |
5 | Hardness | < 50ppm |
RO PLANT OPERATING CONDITION
Sl. No. | Parameter | Analysis Value |
---|---|---|
1 | Feed Flow Rate | 250 Ltr |
2 | Product Flow Rate | 100 LPH |
3 | Rejest Flow Rate | 150 LPH |
4 | Recovery | 35% to 40% |
TREATMENT SCHEME
Sl. No. | Description |
---|---|
1 | Raw Water Transfer Pump |
2 | Multi–Grade Filter |
3 | Activated Carbon Filter |
4 | Antiscalant Dosing System |
5 | Micron Filter ( 20 micron & 5 micron ) |
6 | High Pressure Pump |
7 | RO Module (Membrane & Membrane Housing) |
8 |
Flushing/Cleaning System,Products (Pure) Water Storge Tank (By Client) |
The end water quality is achieved subject to:
TECHNICAL SPECIFICATION
1. Raw Water Transfer Pump: | |
Quantity Required | One |
Material of Construction | CI |
Make of Material | Kirloskar/c.g |
2. Multi-Grade Filter: | |
Quanitity Requires | One |
Sixe of Unit Dia X Ht | 13" X 54" |
Material of Construction | FRP |
Max. Pressure Drop | 0.5Kg/cm² |
Floe Control | Top Mounted multi port valve |
Media | Graded silex anthracite & sand |
Vessel make | Water Life/ Aventurs/ roosh |
3. Activated carbon Filter: | |
Quanitity Requires | One |
Sixe of Unit Dia X Ht | 13" X 54" |
Material of Construction | FRP |
Max. Pressure Drop | 0.5Kg/cm² |
Floe Control | Top Mounted multi port valve |
Media | Activated Carbon |
Vessel make | Water Life/ Aventurs/ roosh |
4. Antiscaling Dosing System: | |
Tank | One |
Capacity of Tank | 100 Ltr |
MOC of Tank | HDPE |
5. Dosing Pump: | |
Quantity required | One |
Type | Diaphragm Type Electronic Pump |
Capacity | 0.5 LPH |
Make | E-dose |
6. Micron Filter: | |
Quantity requires | 2 |
Type | Disposable Cartridge |
Operation Rate | 1.0m³/hr |
Operation Pressure | 2.5Kg/cm² |
Micron Rating | 5 micron |
Type of Cartridge | PP Wound |
MOC | PP |
7. High Pressure Pump: | |
Quantity required | One |
Operating flow rate | 7.5m³/hr |
Operating pressure | 10 – 12 Kg/cm² |
Make of pump | cri./raj |
Type of drive | single phase |
8. RO Membrane: | |
Quantity required | One |
Dimension | Dia 4″, Length 40″ |
Working Pressure | 180 psi |
Element | Spiral Wound Membrane |
Make | Filmtech Dow (USA), super flow (USA) |
9. Electrical Control Panel | |
Quantity required | One |
MOC of Pump | 1 HP |
Material of construction | MS skid mount |
Electrical components make | L&T/Siemens/Havell’s./CAURAM |
10. Flushing Cleaning System: Connected from feed pump | |
Quantity required | One |
MoC of pump | 1 HP |
Capacity | 1.5m³/hr at 2.5Kg/cm² |
UPVC Fitting | 1 Lot |
INSTRUMENTS :
PIPE FITTING: UPVC
SKID: M.S. duly painted/powder coated
EXCLUSIONS
The following are specifically excluded from our scope of work:
PLANT INTRODUCTION This produces quality water at the flow rate of 1000 litres per hour. It can work continuously for 8 to 9 hours per day besides 0.5 hour to 1 hour for back-washing of the filtration system.
Raw Water Analysis:This water treatment system is based on the following water analysis:
Raw Water Analysis
Sl. No. | Parameter | Analysis Value |
---|---|---|
1 | Total Dissolved Solids (TDS) | 2000ppm |
2 | Turbidity | 1 NTU |
3 | SDI | 4 |
4 | Heavy Metals | NIL |
5 | Organics And Bacteria | NIL |
6 | Oil And Grease | NIL |
7 | Residual Chlorine | NIL |
8 | Temperature | < 40˚C |
9 | Color | Colorless |
10 | Odour | Very Less Odour |
11 | BOD & COD | NIL |
12 | Total Hardness | 850 PPM |
END WATER QUALITY
Sl. No. | Parameter | Analysis Value |
---|---|---|
1 | Total Dissolved Solids (TDS) | < 200ppm |
2 | PH | 7.0 ± 0.2 |
3 | Turbidity | NIL |
4 | Color | NIL |
5 | Hardness | < 50ppm |
RO PLANT OPERATING CONDITION
Sl. No. | Parameter | Analysis Value |
---|---|---|
1 | Feed Flow Rate | 650 Ltr |
2 | Product Flow Rate | 250 LPH |
3 | Rejest Flow Rate | 400 LPH |
4 | Recovery | 35% to 40% |
TREATMENT SCHEME
Sl. No. | Description |
---|---|
1 | Raw Water Transfer Pump |
2 | Multi–Grade Filter |
3 | Activated Carbon Filter |
4 | Antiscalant Dosing System |
5 | Micron Filter ( 20 micron & 5 micron ) |
6 | High Pressure Pump |
7 | RO Module (Membrane & Membrane Housing) |
8 | Flushing/Cleaning System,Products (Pure) Water Storge Tank (By Client) |
The end water quality is achieved subject to:
TECHNICAL SPECIFICATION
1. Raw Water Transfer Pump: | |
---|---|
Quantity Required | One |
Material of Construction | CI |
Make of Material | Kirloskar/c.g |
2. Multi-Grade Filter: | |
Quanitity Requires | One |
Sixe of Unit Dia X Ht | 13" X 54" |
Material of Construction | FRP |
Max. Pressure Drop | 0.5Kg/cm² |
Floe Control | Top Mounted multi port valve |
Media | Graded silex anthracite & sand |
Vessel make | Water Life/ Aventurs/ roosh |
3. Activated carbon Filter: | |
Quanitity Requires | One |
Sixe of Unit Dia X Ht | 13" X 54" |
Material of Construction | FRP |
Max. Pressure Drop | 0.5Kg/cm² |
Floe Control | Top Mounted multi port valve |
Media | Activated Carbon |
Vessel make | Water Life/ Aventurs/ roosh |
4. Antiscaling Dosing System: | |
Tank | One |
Capacity of Tank | 100 Ltr |
MOC of Tank | HDPE |
5. Dosing Pump: | |
Quantity required | One |
Type | Diaphragm Type Electronic Pump |
Capacity | 0.5 LPH |
Make | E-dose |
6. Micron Filter: | |
Quantity requires | 2 |
Type | Disposable Cartridge |
Operation Rate | 1.0m³/hr |
Operation Pressure | 2.5Kg/cm² |
Micron Rating | 5 micron |
Type of Cartridge | PP Wound |
MOC | PP |
7. High Pressure Pump: | |
Quantity required | One |
Operating flow rate | 7.5m³/hr |
Operating pressure | 10 – 12 Kg/cm² |
Make of pump | cri./raj |
Type of drive | single phase |
8. RO Membrane: | |
Quantity required | One |
Dimension | Dia 4″, Length 40″ |
Working Pressure | 180 psi |
Element | Spiral Wound Membrane |
Make | Filmtech Dow (USA), super flow (USA) |
9. Electrical Control Panel | |
Quantity required | One |
MOC of Pump | 1 HP |
Material of construction | MS skid mount |
Electrical components make | L&T/Siemens/Havell’s./CAURAM |
10. Flushing Cleaning System: Connected from feed pump | |
Quantity required | One |
MoC of pump | 1 HP |
Capacity | 1.5m³/hr at 2.5Kg/cm² |
UPVC Fitting | 1 Lot |
INSTRUMENTS :
PIPE FITTING: UPVC
SKID: M.S. duly painted/powder coated
EXCLUSIONS
The following are specifically excluded from our scope of work:
Plant Introduction: This produces quality water at the flow rate of 500 liters per hour. It can work continuously for 8 to 9 hours per day besides 0.5 hour to 1 hour for back-washing of the filtration system. Raw Water Analysis:This water treatment system is based on the following water analysis:
Raw Water Analysis
Sl. No. | Parameter | Analysis Value |
---|---|---|
1 | Total Dissolved Solids (TDS) | 2000ppm |
2 | Turbidity | 1 NTU |
3 | SDI | 4 |
4 | Heavy Metals | NIL |
5 | Organics And Bacteria | NIL |
6 | Oil And Grease | NIL |
7 | Residual Chlorine | NIL |
8 | Temperature | < 40˚C |
9 | Color | Colorless |
10 | Odour | Very Less Odour |
11 | BOD & COD | NIL |
12 | Total Hardness | 850 PPM |
END WATER QUALITY
Sl. No. | Parameter | Analysis Value |
---|---|---|
1 | Total Dissolved Solids (TDS) | < 200ppm |
2 | PH | 7.0 ± 0.2 |
3 | Turbidity | NIL |
4 | Color | NIL |
5 | Hardness | < 50ppm |
RO PLANT OPERATING CONDITION
Sl. No. | Parameter | Analysis Value |
---|---|---|
1 | Feed Flow Rate | -Ltr |
2 | Product Flow Rate | 500 LPH |
3 | Rejest Flow Rate | - LPH |
4 | Recovery | 35% to 40% |
TREATMENT SCHEME
Sl. No. | Description |
---|---|
1 | Raw Water Transfer Pump |
2 | Multi–Grade Filter |
3 | Activated Carbon Filter |
4 | Antiscalant Dosing System |
5 | Micron Filter ( 20 micron & 5 micron ) |
6 | High Pressure Pump |
7 | RO Module (Membrane & Membrane Housing) |
8 | Flushing/Cleaning System,Products (Pure) Water Storge Tank (By Client) |
The end water quality is achieved subject to:
TECHNICAL SPECIFICATION
1. Raw Water Transfer Pump: | |
---|---|
Quantity Required | One |
Material of Construction | CI |
Make of Material | Kirloskar/c.g |
2. Multi-Grade Filter: | |
Quanitity Requires | One |
Sixe of Unit Dia X Ht | 13" X 54" |
Material of Construction | FRP |
Max. Pressure Drop | 0.5Kg/cm² |
Floe Control | Top Mounted multi port valve |
Media | Graded silex anthracite & sand |
Vessel make | Water Life/ Aventurs/ roosh |
3. Activated carbon Filter: | |
Quanitity Requires | One |
Sixe of Unit Dia X Ht | 13" X 54" |
Material of Construction | FRP |
Max. Pressure Drop | 0.5Kg/cm² |
Floe Control | Top Mounted multi port valve |
Media | Activated Carbon |
Vessel make | Water Life/ Aventurs/ roosh |
4. Antiscaling Dosing System: | |
Tank | One |
Capacity of Tank | 100 Ltr |
MOC of Tank | HDPE |
5. Dosing Pump: | |
Quantity required | One |
Type | Diaphragm Type Electronic Pump |
Capacity | 0.5 LPH |
Make | E-dose/Kemflo-faq |
6. Micron Filter: | |
Quantity requires | 2 |
Type | Disposable Cartridge |
Operation Rate | 1.0m³/hr |
Operation Pressure | 2.5Kg/cm² |
Micron Rating | 5 micron |
Type of Cartridge | PP Wound |
MOC | PP |
7. High Pressure Pump: | |
Quantity required | One |
Operating flow rate | 7.5m³/hr |
Operating pressure | 10 – 12 Kg/cm² |
Make of pump | Sumo/cri./roosh |
Type of drive | single phase |
8. RO Membrane Housing: | |
Quantity required | One |
Material of Pressure Tube | 4″ × 40″ |
Element Capacity | 2 nos. |
Max.Working pressure | 250 psi |
Make | Waterlife/roosh/aventura |
9. RO Membrane: | |
Quantity required | 2 nos |
Dimension | Dia 4″, Length 40″ |
Working Pressure | 180 psi |
Element | Spiral Wound Membrane |
Make | Filmtech Dow (USA), super flow (USA) |
10. Electrical Control Panel | |
Quantity required | One |
Material of construction | MS skid mount |
Electrical components make | L&T/Siemens/Havell’s./CAURAM |
11. Flushing Cleaning System: Connected from feed pump | |
Quantity required | One |
MoC of pump | 1 HP |
Capacity | 1.5m³/hr at 2.5Kg/cm² |
UPVC Fitting | 1 Lot |
INSTRUMENTS :
PIPE FITTING: UPVC
SKID: M.S. duly painted/powder coated
EXCLUSIONS
The following are specifically excluded from our scope of work:
PLANT INTRODUCTION This produces quality water at the flow rate of 1000 litres per hour. It can work continuously for 8 to 9 hours per day besides 0.5 hour to 1 hour for back-washing of the filtration system.
Raw Water Analysis:This water treatment system is based on the following water analysis:
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T, Western Union,
TECHNICAL SPECIFICATION
1. Raw Water Transfer Pump: | |
---|---|
Quantity Required | One |
Material of Construction | CI |
Make of Material | Kirloskar/c.g |
2. Multi-Grade Filter: | |
Quanitity Requires | One |
Sixe of Unit Dia X Ht | 13" X 54" |
Material of Construction | FRP |
Max. Pressure Drop | 0.5Kg/cm² |
Floe Control | Top Mounted multi port valve |
Media | Graded silex anthracite & sand |
Vessel make | Aventura |
3. Dosing Pump: | |
Quantity required | One |
Type | Diaphragm Type Electronic Pump |
Capacity | 0.5 LPH |
Make | E-dose |
4. Micron Filter: | |
Quantity requires | 2 |
Type | Disposable Cartridge |
Operation Rate | 1.0m³/hr |
Operation Pressure | 2.5Kg/cm² |
Micron Rating | 5 micron |
Type of Cartridge | PP Wound |
MOC | PP |
5. High Pressure Pump: | |
Quantity required | One |
Operating flow rate | 7.5m³/hr |
Operating pressure | 10 – 12 Kg/cm² |
Make of pump | cri./raj |
Type of drive | single phase |
6. RO Membrane: | |
Quantity required | One |
Dimension | Dia 4″, Length 40″ |
Working Pressure | 180 psi |
Element | Spiral Wound Membrane |
Make | Hydrostatic membrane from Pentair India |
7. Electrical Control Panel | |
Quantity required | One |
Material of construction | MS skid mount |
Electrical components make | B |
INSTRUMENTS :
PIPE FITTING: UPVC
SKID: M.S. duly painted/powder coated
EXCLUSIONS
The following are specifically excluded from our scope of work: