Post Buy Requirement
AC
Delhi, India
Add Review

Our Products

  1. Instrumentation Cables 4 Products available
  2. Power Cables 18 Products available
  3. Electrical Cables & Wires 16 Products available
  4. Fiber Optic Cables 3 Products available
  5. Computer Hardware & Peripherals 4 Products available
  6. Others 27 Products available

Electrical Cables & Wires #340294

Fire Resistant Armoured Pair Screened I & C Cable

With vast industrial expertise, we are involved in manufacturing, supplying and exporting the best quality Fire Resistant Armoured Pair Screened I & C Cable 250V. We make use of the high-grade materials while manufacturing these Fire Resistant Armoured and Pair Screened Instrumentation and Communication Cable. Application : For fixed installation in most areas and on open deck in ships. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Highlights
  • Minimum recommended installation temperature -15 oC
  • Lowest operation temperature -40 oC
  • Identification : Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath.
  • Core Identification : Each pair white - blue. Cores numbered 1, 2, 3, 4, 5. The pairs are also covered by a numbered tape (1, 2, 3, 4, 5.)

Main Characteristics

Rated Voltage 150/250V (300V)
Maximum Conductor Temperature + 90oC
Flame Retardant IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables, category A
Fire Resistant IEC 60331-21
Halogen Free IEC 60754 series
Smoke Emission IEC 61034 series

Electrical Data

Parameters 0,75mm2 1,5mm2 Unit
Loop resistance of pair, max. / +20oC 52 24,4 ohm/km
Pair capacitance, nom. / 800Hz 55 75 nF/km
Loop inductance, nom. 0,6 0,7 mH/km
Insulation resistance / +20oC ≥1500 ≥1500 Mohm*km.

Specifications

RFE-FRHF(i) 250VNumber of conductors & cross-section n x mm2Nominal outer diameter mmApproximate weight kg/kmMin. bending radius fixed installation mm
Part number
20 5461x2x0,759,512560
20 5502x2x0,7514,522590
20 5524x2x0,7517,0355105
20 5547x2x0,7520,0515125
20 5568x2x0,7522,0585135
20 55810x2x0,7525,0710150
20 56012x2x0,7526,0800155
20 56214x2x0,7527,5910170
20 56419x2x0,7532,01175195
20 56624x2x0,7535,01425215
20 6031x2x1,510,516565
20 6052x2x1,516,5320100
20 6074x2x1,519,0475115
20 6097x2x1,523,0720140
20 6118x2x1,524,5810150
20 61310x2x1,528,0985170
20 61512x2x1,529,51145180
20 61714x2x1,531,51295190
View Complete Details

Fire Resistant Armoured I & C Cable

The company is the credible Manufacturer, Supplier and Exporter of the best quality Fire Resistant Armoured I & C Cable 250V. Fire Resistant Armoured Instrumentation and Communication Cable is being tested on various parameters before the final delivery. Customers can avail these Fire Resistant Armoured Instrumentation and Communication Cable, from us, at the market leading prices. Application : For fixed installation in most areas and on open deck in ships. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Highlights
  • Minimum recommended installation temperature -15 oC
  • Lowest operation temperature -40 oC
  • Identification : Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath.

Main Characteristics

Rated Voltage 150/250V (300V)
Maximum Conductor Temperature + 90oC
Flame Retardant IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables, category A
Fire Resistant IEC 60331-21
Halogen Free IEC 60754 series
Smoke Emission IEC 61034 series

Electrical Data

Parameters 0,75mm2 1,5mm2 Unit
Loop resistance of pair, max. / +20oC 52 24,4 ohm/km
Pair capacitance, nom. / 800Hz 45 55 nF/km
Loop inductance, nom. 0,6 0,7 mH/km
Insulation resistance / +20oC ≥1500 ≥1500 Mohm*km.

Specifications

RFE-FRHF 250VNumber of conductors & cross-section n x mm2Nominal outer diameter mmApproximate weight kg/kmMin. bending radius fixed installation mm
Part number
20 5201x2x0,759,511560
20 5222x2x0,75 Quad11,016070
20 5242x2x0,7514,021085
20 5264x2x0,7516,5325100
20 5287x2x0,7520,0465120
20 5308x2x0,7521,0510130
20 53210x2x0,7524,5630150
20 53412x2x0,7525,5705155
20 53614x2x0,7527,0800165
20 53819x2x0,7531,01015190
20 54024x2x0,7534,51245210
20 5751x2x1,510,515565
20 5772x2x1,5 Quad12,022075
20 5792x2x1,516,0315100
20 5814x2x1,518,5430115
20 5837x2x1,522,5650140
20 5858x2x1,524,0715150
20 58710x2x1,527,5875165
20 58912x2x1,529,01000175
20 59114x2x1,530,51125185
View Complete Details

Armoured Pair Screened I & C Cable

The company is excelling in the domain of manufacturing, supplying and exporting the best quality Armoured Pair Screened I & C Cable 250V. Armoured Pair Screened I & C Cable is high-on demand in varied industrial applications. Application : For fixed installation in most areas and on open deck in ships. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Highlights
  • Minimum recommended installation temperature -15 oC
  • Lowest operation temperature -40 oC
  • Identification : Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath.
  • Core Identification : Each pair white - blue. Cores numbered 1, 2, 3, 4, 5.The pairs are also covered by a numbered tape (1, 2, 3, 4, 5.)

Main Characteristics

Rated Voltage 150/250V (300V)
Maximum Conductor Temperature + 90oC
Flame Retardant IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables, category A
Fire Resistant IEC 60331-21
Halogen Free IEC 60754 series
Smoke Emission IEC 61034 series

Electrical Data

Parameters 0,75mm2 1,5mm2 Unit
Loop resistance of pair, max. / +20oC 52 24,4 ohm/km
Pair capacitance, nom. / 800Hz 55 75 nF/km
Loop inductance, nom. 0,6 0,7 mH/km
Insulation resistance / +20oC ≥1500 ≥1500 Mohm*km.

Specifications

RFE-FRHF(i) 250VNumber of conductors & cross-section n x mm2Nominal outer diameter mmApproximate weight kg/kmMin. bending radius fixed installation mm
Part number
20 5461x2x0,759,512560
20 5502x2x0,7514,522590
20 5524x2x0,7517,0355105
20 5547x2x0,7520,0515125
20 5568x2x0,7522,0585135
20 55810x2x0,7525,0710150
20 56012x2x0,7526,0800155
20 56214x2x0,7527,5910170
20 56419x2x0,7532,01175195
20 56624x2x0,7535,01425215
20 6031x2x1,510,516565
20 6052x2x1,516,5320100
20 6074x2x1,519,0475115
20 6097x2x1,523,0720140
20 6118x2x1,524,5810150
20 61310x2x1,528,0985170
20 61512x2x1,529,51145180
20 61714x2x1,531,51295190
View Complete Details

Armoured I & C Cable

We feel pride in presenting ourselves as one of the trusted Manufacturers, Suppliers and Exporters of the best quality Armoured Power Cable i.e. Armoured I & C Cable 250V. Armoured Instrumentation and Communication Cable is made using quality materials and modern facilities. These Armoured Instrumentation and Communication Cables are widely appreciated for their quality, reliability and efficiency. The clients can avail Armoured Power Cables from us in different specifications in bulk quantities. Highlights
  • Minimum recommended installation temperature -15 oC
  • Lowest operation temperature -40 oC
  • Identification : Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath

Main Characteristics

Rated Voltage 150/250V (300V)
Maximum Conductor Temperature + 90oC
Flame Retardant IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables, category A
Halogen Free IEC 60754 series
Smoke Emission IEC 61034 series

Electrical Data

Parameters 0,5mm2 0,75mm2 1,5mm2 Unit
Loop resistance of pair, max. / +20oC 80 52 24,4 ohm/km
Pair capacitance, nom. / 800Hz 55 50 60 nF/km
Loop inductance, nom. 0,6 0,6 0,7 mH/km
Insulation resistance / +20oC ≥1500 ≥1500 ≥1500 Mohm*km.

Specifications

RFE-FRHF(i) 250VNumber of conductors & cross-section n x mm2Nominal outer diameter mmApproximate weight kg/kmMin. bending radius fixed installation mm
Part number
20 3621x2x0,57,58545
20 3642x2x0,5 Quad8,010050
20 3632x2x0,510,513065
20 3664x2x0,511,517070
20 3687x2x0,514,024585
20 3698x2x0,514,527090
20 37010x2x0,517,0350105
20 37112x2x0,517,5390105
20 37214x2x0,518,5440115
20 37419x2x0,521,0545130
20 37624x2x0,523,5665145
20 37837x2x0,528,0930170
20 3821x2x0,757,59545
20 3842x2x0,75 Quad9,012555
20 3832x2x0,7511,015570
20 3864x2x0,7512,521575
20 3887x2x0,7515,533095
20 3898x2x0,7516,0375100
20 39010x2x0,7518,5440115
20 39112x2x0,7519,0490115
20 39214x2x0,7520,5565125
20 39419x2x0,7523,5715145
20 39624x2x0,7526,0860160
20 4901x2x1,510,014060
20 4912x2x1,5 Quad11,019070
20 4922x2x1,514,523590
20 4934x2x1,517,0375105
20 4947x2x1,520,0545120
20 4958x2x1,521,5625130
20 49610x2x1,524,5760150
20 49712x2x1,525,5855155
20 49814x2x1,527,0960165
20 49919x2x1,531,01230190
View Complete Details

Fire Resistant Collectively Pair Screened I & C Cable

Fire Resistant Collectively Pair Screened I & C Cable 250V, which we offer, is the best owing to its varied features such as flame retardant, fire-resistant, halogen-free and low smoke emission. We offer these Fire Resistant Collectively and Pair Screened Instrumentation and Communication Cables at the market leading rates to the clients. Application : For fixed installation in most areas and on open deck in ships. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Highlights
  • Minimum recommended installation temperature -15 oC
  • Lowest operation temperature -40 oC
  • Identification : Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath
  • Core Identification
    • Each pair white - blue. Cores numbered 1, 2, 3, 4, 5.
    • The pairs are also covered by a numbered tape (1, 2, 3, 4, 5.)

Main Characteristics

Rated Voltage 150/250V (300V)
Maximum Conductor Temperature + 90oC
Flame Retardant IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables, category A
Fire Resistant IEC 60331-21
Halogen Free IEC 60754 series
Smoke Emission IEC 61034 series

Electrical Data

Parameters 0,75mm2 Unit
Loop resistance of pair, max. / +20oC 52 ohm/km
Pair capacitance, nom. / 800Hz 55 nF/km
Loop inductance, nom. 0,6 mH/km
Insulation resistance / +20oC ≥1500 Mohm*km.

Specifications

RFA-FRHF(i) 250VNumber of conductors & cross-section n x mm2Nominal outer diameter mmApproximate weight kg/kmMin. bending radius fixed installation mm
Part number
20 6672x2x0,7513,515585
20 6694x2x0,7515,524595
20 6717x2x0,7518,5380115
20 6738x2x0,7520,0430120
20 67510x2x0,7523,5545145
20 67712x2x0,7524,5625150
20 67914x2x0,7526,0725160
20 68319x2x0,7530,0945180
20 68524x2x0,7534,01205205
View Complete Details

Fire Resistant Screened I & C Cable

The company is the premium Manufacturer, Supplier and Exporter of the Fire Resistant Screened I & C Cable 250V. The company makes use of the latest technology while manufacturing the Fire Resistant Screened Instrumentation and Communication Cable. Fire Resistant Screened Instrumentation and Communication Cable can be availed, from us, at the market leading prices. Application : For fixed installation in most areas and on open deck in ships. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Highlights
  • Minimum recommended installation temperature -15 oC
  • Lowest operation temperature -40 oC
  • Identification : Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath

Main Characteristics

Rated Voltage 150/250V (300V)
Maximum Conductor Temperature + 90oC
Flame Retardant IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables, category A
Fire Resistant IEC 60331-21
Halogen Free IEC 60754 series
Smoke Emission IEC 61034 series

Electrical Data

Parameters 0,75mm2 Unit
Loop resistance of pair, max. / +20oC 52 ohm/km
Pair capacitance, nom. / 800Hz 45 nF/km
Loop inductance, nom. 0,6 mH/km
Insulation resistance / +20oC ≥1500 Mohm*km.

Specifications

RFA-FRHF 250VNumber of conductors & cross-section n x mm2Nominal outer diameter mmApproximate weight kg/kmMin. bending radius fixed installation mm
Part number
20 6351x2x0,758,57555
20 6372x2x0,75 Quad10,012060
20 6392x2x0,7513,013580
20 6414x2x0,7515,521595
20 6437x2x0,7518,5330115
20 6458x2x0,7520,0380120
20 64710x2x0,7523,0480140
20 64912x2x0,7524,0545145
20 65114x2x0,7525,5620155
20 65519x2x0,7529,5805180
20 65724x2x0,7533,51030205
View Complete Details

Fire Resistant Screened Control And Instrumentation Cable

Fire Resistant Screened Control and Instrumentation Cable (250V), which we provide, is manufactured in confirmation to the established standards. We are rated amongst the reliable Manufacturers, Exporters and Suppliers of Fire Resistant Screened Control and Instrumentation Cable, located in New Delhi. Applications
  • For fixed installation in most areas and on open deck in ships, especially when lightweight cables are needed
  • If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended
Highlights
  • Minimum recommended installation temperature -15 oC
  • Lowest operation temperature -40 oC
  • Core Identification : black numbers on white base
  • Identification : Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath

Main Characteristics

Rated Voltage 150/250V (300V)
Maximum Conductor Temperature + 90oC
Flame Retardant IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables, category A
Fire Resistant IEC 60331-21 series
Halogen Free IEC 60754 series
Smoke Emission IEC 61034 series

Specifications

LKAM-FRHF 250VNumber of conductors & cross-section n x mm2Nominal outer diameter mmApproximate weight kg/kmCurrent rating AMin. bending radius fixed installation mm
Part number
224662x0,758,57011,350
224673x0,759,0859,855
224684x0,7510,01158,960
224695x0,7511,01358,365
224707x0,7511,51657,470
2247110x0,7515,02306,690
2247212x0,7515,52606,295
2247314x0,7516,53005,9100
2247416x0,7517,53405,6105
2247519x0,7518,03805,3110
2247724x0,7521,54804,9130
2247827x0,7522,05254,7130
2247932x0,7523,06204,5140
2248037x0,7525,07004,3150

View Complete Details

Fire Resistant Armoured Control And Instrumentation Cable

Fire Resistant Armoured Control and Instrumentation Cable (250V) is manufactured in confirmation to the set industrial standards. We offer these Fire Resistant Armoured Control and Instrumentation Cables at the market leading rates to the clients. We offer these Fire Resistant Armoured Control and Instrumentation Cables at reasonable rates. Applications
  • For fixed installation in most areas and on open deck in ships
  • If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended
Highlights
  • Minimum recommended installation temperature -15 oC
  • Lowest operation temperature -40 oC
  • Core Identification : black numbers on white base
  • Identification : Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath

Main Characteristics

Rated voltage 150/250V (300V)
Maximum conductor temperature + 90 oC
Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables, category A
Fire-resistant IEC 60331-21 series
Halogen-free IEC 60754 series
Smoke emission IEC 61034 series

Specification

LKSM-FRHF 0,6/1kVNumber ofconductors & cross-section n x mm2Crosssection of screen Mm2Nominal outer diameter MmApproximate weight kg/kmCurrent rating AMin. bending radius fixed installation Mm
Part number
22436 2x0,75 3,6 9,0 105 11,3 55
22437 3x0,75 3,9 10,0 135 9,8 60
22438 4x0,75 4,4 11,0 160 8,9 65
22439 5x0,75 4,9 11,5 185 8,3 70
22440 7x0,75 5,4 12,5 220 7,4 75
22441 10x0,75 11,6 16,0 350 6,6 95
22442 12x0,75 11,6 16,5 380 6,2 100
22443 14x0,75 11,7 17,5 415 5,9 105
22444 16x0,75 11,3 18,5 445 5,6 110
22445 19x0,75 11,9 19,5 505 5,3 115
22447 24x0,75 14,3 23,0 640 4,9 135
22448 27x0,75 14,6 23,5 685 4,7 140
22449 32x0,75 15,3 24,0 765 4,5 145
22450 37x0,75 16,7 26,0 870 4,3 155

View Complete Details

Fire Resistant Unarmoured Control And Instrumentation Cable

Fire Resistant Unarmoured Control and Instrumentation Cable (250V), which we offer, is manufactured using the best-grade materials. We are amongst the dependable Manufacturers, Suppliers and Exporters of Fire Resistant Unarmoured Control and Instrumentation Cable, based in New Delhi. These Fire Resistant Unarmoured Control and Instrumentation Cables can be purchased from us at the market leading rates. Applications
  • For fixed installation in most areas and on open deck in ships.
  • If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended.
Highlights
  • Minimum recommended installation temperature -15 oC
  • Lowest operation temperature -40 oC
  • Core Identification : black numbers on white base
  • Identification : Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath

Main Characteristics

Rated voltage 150/250V (300V)
Maximum Conductor Temperature + 90oC
Flame Retardant IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables, category A
Fire Resistant IEC 60331-21 series
Halogen Free IEC 60754 series
Smoke Emission IEC 61034 series

Specifications

LKAM-HF 250VNumber of conductors & cross-section n x mm2Nominal outer diameter mmApproximate weight kg/kmCurrent rating AMin. bending radius fixed installation mm
Part number
224062x0,758,56511,335
224073x0,759,0809,835
224084x0,7510,01108,940
224095x0,7511,01308,345
224107x0,7511,51607,445
2241110x0,7515,02256,660
2241212x0,7515,52556,260
2241314x0,7516,52955,965
2241416x0,7517,53305,670
2241519x0,7518,03755,375
2241724x0,7521,54754,985
2241827x0,7522,05204,785
2241932x0,7523,06154,590
2242037x0,7525,06954,3100

View Complete Details

Armoured Control And Instrumentation Cable

Alankar Cable Industries is counted amidst the top names in the industry, when it comes to buying a reliable range of Underground Armoured Cables. The company is known as a dynamic Control and Instrumentation Cable Manufacturer, Exporter, and Supplier from New Delhi (India). Manufactured from the premium raw materials, our Underground Armoured Cables perform well under adverse conditions. These Underground Armoured Cables work for longer time than ordinary cables and are safe to use. The Underground Armoured Cables are offered by us in varied specifications, at the most competitive prices. Applications
  • For fixed installation in most areas and on open deck in ships.
  • If the cable is exposed to direct sun light protective covering orcable with black outer sheath is recommended
Highlights
  • Minimum recommended installation temperature -15 oC
  • Lowest operation temperature -40 oC
  • Core Identification : black numbers on white base
  • Identification : Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath

Main Characteristics

Rated voltage 150/250V (300V)
Maximum conductor temperature + 90 oC
Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables, category A
Halogen-free IEC 60754 series
Smoke emission IEC 61034 series

Specification

LKSM-FRHF 0,6/1kVNumber of conductors & cross-section n x mm2Crosssection of screen mm2Nominal outer diameter MmApproximate weight kg/kmCurrent rating AMin. bending radius fixed installation Mm
Part number
26402 2x0,75 3,6 7,5 90 11,3 45
26403 3x0,75 3,6 8,0 100 9,8 50
26404 4x0,75 3,6 8,5 110 8,9 50
26405 5x0,75 4,1 9,5 140 8,3 55
26407 7x0,75 4,1 10,0 160 7,4 60
26410 10x0,75 5,1 12,5 220 6,6 70
26412 12x0,75 5,3 13,0 240 6,2 75
26414 14x0,75 5,6 13,5 265 5,9 75
26416 16x0,75 6,1 14,0 295 5,6 80
26419 19x0,75 8,7 14,5 330 5,3 85
26424 24x0,75 11,7 17,5 450 4,9 100
26427 27x0,75 11,7 17,5 480 4,7 100
26432 32x0,75 11,8 18,5 540 4,5 105
26437 37x0,75 11,9 19,5 600 4,3 115

View Complete Details

Jz-500 Hmh Halogen Free Control Cable

  • Min. Order (MOQ) 1000 Meter
  • Brand Name ALANKAR / ALANCAB
  • HALOGEN FREE
  • LEAD FREE
We are offering jz-500 hmh halogen free control cable. jz-hmh control cablehalogen-free flexible control cable, core construction adapted to din vde 0281 part 14 and din vde 0281 part 13temperature rangeflexing -15c to +70cfixed installation -40c to +70cnominal voltage u0/u 300/500 vtest voltage 2000 vminimum bending radiusflexing approx. 12, 5x cable fixed installation approx. 4x cable .

Additional Information:

Payment Terms : L/C, T/T

Packaging Details : WOODEN DRUMS OR CORRUGATED BOXES

Delivery Time : ONE MONTH IN INDIA/PORT

View Complete Details

Rdh(st)h Halogen Free Instrumentation Cable

  • Min. Order (MOQ) 1000 Meter
  • Brand Name ALANKAR / ALANCAB
  • HALOGEN FREE
  • LEAD FREE
We are offering rdh(st)h halogen free instrumentation cable. Rdh (st) h installation cablehalogen-free data transmission cable adapted to din vde 0815conductor resistancemax. 73.6 ohm/km (0.5 mm)max. 36.8 ohm/km (1.0 mm)temperature rangeflexing -5c to +50c (+23f to +122f)fixed installation to +70c/+158fnominal voltage max. 225 vtest voltageconductor/conductor 500 vconductor/shield 2000 vinsulation resistancemin. 100 mohm x kmmutual capacitanceat 800 hz max. 100 nf/km(this value may be exceeded by 20% with a make-up up to 4 pairs) impedance at 1 khz (nominal values)450 ohm (0.5 mm)320 ohm (1.0 mm)capacity unbalanceat 800 hz max. 200 pf/100 m(20% of the values, but one value up to 200 pf is allowed)cross-talk attenuationat min. 10 khz, 60 db/500 mline attenuation at 1 khz (nominal values)1.2 db/km (0.5 mm)0.9 db/km (1.0 mm)bending radiusapprox. 7.5x cable bare copper stranded wires 0.5 mm (7x0.3) or 1.0 mm (7x0.43)conductor insulation, halogen-free polymer compoundconductors twisted in pairs, with short lay-length(approx. 20 pitch/m 50 mm)4 pairs stranded to a unitholding tape units with number codingunits stranded in concentric layersconductor wrappingelectrostatic shield of plastic coated aluminum foil and drain wire tinned, 0.5 mmouter jacket, halogen-free, polymer compound, flame resistantcolor: grayconductor colorspair no./a-conductor/b-conductor1/blue/red2/grey/yellow3/green/brown4/white/black(4 pairs 1 unit)application the halogen-free data transmission cable rd-h(st)h are used for measurement and control technology for transmission of analog and digital signals up to frequencies of approx. 10 khz. The twisted pairs with short pitches.

Additional Information:

Payment Terms : L/C

Packaging Details : WOODEN DRUMS OR CORRUGATED BOXES

Delivery Time : ONE MONTH IN INDIA/PORT

View Complete Details

Rz 1k Halogen Free Energy Cable

  • Min. Order (MOQ) 1000 Meter
  • Brand Name ALANKAR / ALANCAB
  • HALOGEN FREE
  • LEAD FREE
  • CONDUCTOR FLEXIBLE
We are offering rz 1k halogen free energy cable. halogen-free flexible power cable, core construction adapted to din vde 0281 part 14 and din vde 0281 part 13temperature rangeflexing -15c to +70cfixed installation -40c to +70cnominal voltage u0/u 1000 vtest voltage 3000 vminimum bending radiusflexing approx. 12, 5x cable fixed installation approx. 4x cable .

Additional Information:

Payment Terms : L/C, T/T

Packaging Details : WOODEN DRUMS OR CORRUGATED BOXES

Delivery Time : ONE MONTH IN INDIA/PORT

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

Retailer of Electrical Cables & Wires from Delhi, Delhi by Alankar Cable Industries
Post Buy Requirement
AC

Alankar Cable Industries

Add Review

Our Products

  1. Power Cables 18 Products available
  2. Electrical Cables & Wires 16 Products available
  3. Computer Hardware & Peripherals 4 Products available
  4. Instrumentation Cables 4 Products available
  5. Fiber Optic Cables 3 Products available
  6. Thermocouple Cables

    2 Products available
  7. Industrial Wires

    2 Products available
  8. Wires

    2 Products available
  9. Electronic Cables

    2 Products available
  10. Electrical Conductor

    1 Products available
  11. Others Products 18 Products available

Electrical Cables & Wires

Our offered Product range includes Fire Resistant Armoured Pair Screened I & C Cable, Fire Resistant Armoured I & C Cable, Armoured Pair Screened I & C Cable, Armoured I & C Cable and Fire Resistant Collectively Pair Screened I & C Cable.

Fire Resistant Armoured Pair Screened I & C Cable

With vast industrial expertise, we are involved in manufacturing, supplying and exporting the best quality Fire Resistant Armoured Pair Screened I & C Cable 250V. We make use of the high-grade materials while manufacturing these Fire Resistant Armoured and Pair Screened Instrumentation and Communication Cable. Application : For fixed installation in most areas and on open deck in ships. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Highlights
  • Minimum recommended installation temperature -15 oC
  • Lowest operation temperature -40 oC
  • Identification : Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath.
  • Core Identification : Each pair white - blue. Cores numbered 1, 2, 3, 4, 5. The pairs are also covered by a numbered tape (1, 2, 3, 4, 5.)

Main Characteristics

Rated Voltage 150/250V (300V)
Maximum Conductor Temperature + 90oC
Flame Retardant IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables, category A
Fire Resistant IEC 60331-21
Halogen Free IEC 60754 series
Smoke Emission IEC 61034 series

Electrical Data

Parameters 0,75mm2 1,5mm2 Unit
Loop resistance of pair, max. / +20oC 52 24,4 ohm/km
Pair capacitance, nom. / 800Hz 55 75 nF/km
Loop inductance, nom. 0,6 0,7 mH/km
Insulation resistance / +20oC ≥1500 ≥1500 Mohm*km.

Specifications

RFE-FRHF(i) 250VNumber of conductors & cross-section n x mm2Nominal outer diameter mmApproximate weight kg/kmMin. bending radius fixed installation mm
Part number
20 5461x2x0,759,512560
20 5502x2x0,7514,522590
20 5524x2x0,7517,0355105
20 5547x2x0,7520,0515125
20 5568x2x0,7522,0585135
20 55810x2x0,7525,0710150
20 56012x2x0,7526,0800155
20 56214x2x0,7527,5910170
20 56419x2x0,7532,01175195
20 56624x2x0,7535,01425215
20 6031x2x1,510,516565
20 6052x2x1,516,5320100
20 6074x2x1,519,0475115
20 6097x2x1,523,0720140
20 6118x2x1,524,5810150
20 61310x2x1,528,0985170
20 61512x2x1,529,51145180
20 61714x2x1,531,51295190
View Complete Details

Fire Resistant Armoured I & C Cable

The company is the credible Manufacturer, Supplier and Exporter of the best quality Fire Resistant Armoured I & C Cable 250V. Fire Resistant Armoured Instrumentation and Communication Cable is being tested on various parameters before the final delivery. Customers can avail these Fire Resistant Armoured Instrumentation and Communication Cable, from us, at the market leading prices. Application : For fixed installation in most areas and on open deck in ships. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Highlights
  • Minimum recommended installation temperature -15 oC
  • Lowest operation temperature -40 oC
  • Identification : Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath.

Main Characteristics

Rated Voltage 150/250V (300V)
Maximum Conductor Temperature + 90oC
Flame Retardant IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables, category A
Fire Resistant IEC 60331-21
Halogen Free IEC 60754 series
Smoke Emission IEC 61034 series

Electrical Data

Parameters 0,75mm2 1,5mm2 Unit
Loop resistance of pair, max. / +20oC 52 24,4 ohm/km
Pair capacitance, nom. / 800Hz 45 55 nF/km
Loop inductance, nom. 0,6 0,7 mH/km
Insulation resistance / +20oC ≥1500 ≥1500 Mohm*km.

Specifications

RFE-FRHF 250VNumber of conductors & cross-section n x mm2Nominal outer diameter mmApproximate weight kg/kmMin. bending radius fixed installation mm
Part number
20 5201x2x0,759,511560
20 5222x2x0,75 Quad11,016070
20 5242x2x0,7514,021085
20 5264x2x0,7516,5325100
20 5287x2x0,7520,0465120
20 5308x2x0,7521,0510130
20 53210x2x0,7524,5630150
20 53412x2x0,7525,5705155
20 53614x2x0,7527,0800165
20 53819x2x0,7531,01015190
20 54024x2x0,7534,51245210
20 5751x2x1,510,515565
20 5772x2x1,5 Quad12,022075
20 5792x2x1,516,0315100
20 5814x2x1,518,5430115
20 5837x2x1,522,5650140
20 5858x2x1,524,0715150
20 58710x2x1,527,5875165
20 58912x2x1,529,01000175
20 59114x2x1,530,51125185
View Complete Details

Armoured Pair Screened I & C Cable

The company is excelling in the domain of manufacturing, supplying and exporting the best quality Armoured Pair Screened I & C Cable 250V. Armoured Pair Screened I & C Cable is high-on demand in varied industrial applications. Application : For fixed installation in most areas and on open deck in ships. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Highlights
  • Minimum recommended installation temperature -15 oC
  • Lowest operation temperature -40 oC
  • Identification : Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath.
  • Core Identification : Each pair white - blue. Cores numbered 1, 2, 3, 4, 5.The pairs are also covered by a numbered tape (1, 2, 3, 4, 5.)

Main Characteristics

Rated Voltage 150/250V (300V)
Maximum Conductor Temperature + 90oC
Flame Retardant IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables, category A
Fire Resistant IEC 60331-21
Halogen Free IEC 60754 series
Smoke Emission IEC 61034 series

Electrical Data

Parameters 0,75mm2 1,5mm2 Unit
Loop resistance of pair, max. / +20oC 52 24,4 ohm/km
Pair capacitance, nom. / 800Hz 55 75 nF/km
Loop inductance, nom. 0,6 0,7 mH/km
Insulation resistance / +20oC ≥1500 ≥1500 Mohm*km.

Specifications

RFE-FRHF(i) 250VNumber of conductors & cross-section n x mm2Nominal outer diameter mmApproximate weight kg/kmMin. bending radius fixed installation mm
Part number
20 5461x2x0,759,512560
20 5502x2x0,7514,522590
20 5524x2x0,7517,0355105
20 5547x2x0,7520,0515125
20 5568x2x0,7522,0585135
20 55810x2x0,7525,0710150
20 56012x2x0,7526,0800155
20 56214x2x0,7527,5910170
20 56419x2x0,7532,01175195
20 56624x2x0,7535,01425215
20 6031x2x1,510,516565
20 6052x2x1,516,5320100
20 6074x2x1,519,0475115
20 6097x2x1,523,0720140
20 6118x2x1,524,5810150
20 61310x2x1,528,0985170
20 61512x2x1,529,51145180
20 61714x2x1,531,51295190
View Complete Details

Armoured I & C Cable

We feel pride in presenting ourselves as one of the trusted Manufacturers, Suppliers and Exporters of the best quality Armoured Power Cable i.e. Armoured I & C Cable 250V. Armoured Instrumentation and Communication Cable is made using quality materials and modern facilities. These Armoured Instrumentation and Communication Cables are widely appreciated for their quality, reliability and efficiency. The clients can avail Armoured Power Cables from us in different specifications in bulk quantities. Highlights
  • Minimum recommended installation temperature -15 oC
  • Lowest operation temperature -40 oC
  • Identification : Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath

Main Characteristics

Rated Voltage 150/250V (300V)
Maximum Conductor Temperature + 90oC
Flame Retardant IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables, category A
Halogen Free IEC 60754 series
Smoke Emission IEC 61034 series

Electrical Data

Parameters 0,5mm2 0,75mm2 1,5mm2 Unit
Loop resistance of pair, max. / +20oC 80 52 24,4 ohm/km
Pair capacitance, nom. / 800Hz 55 50 60 nF/km
Loop inductance, nom. 0,6 0,6 0,7 mH/km
Insulation resistance / +20oC ≥1500 ≥1500 ≥1500 Mohm*km.

Specifications

RFE-FRHF(i) 250VNumber of conductors & cross-section n x mm2Nominal outer diameter mmApproximate weight kg/kmMin. bending radius fixed installation mm
Part number
20 3621x2x0,57,58545
20 3642x2x0,5 Quad8,010050
20 3632x2x0,510,513065
20 3664x2x0,511,517070
20 3687x2x0,514,024585
20 3698x2x0,514,527090
20 37010x2x0,517,0350105
20 37112x2x0,517,5390105
20 37214x2x0,518,5440115
20 37419x2x0,521,0545130
20 37624x2x0,523,5665145
20 37837x2x0,528,0930170
20 3821x2x0,757,59545
20 3842x2x0,75 Quad9,012555
20 3832x2x0,7511,015570
20 3864x2x0,7512,521575
20 3887x2x0,7515,533095
20 3898x2x0,7516,0375100
20 39010x2x0,7518,5440115
20 39112x2x0,7519,0490115
20 39214x2x0,7520,5565125
20 39419x2x0,7523,5715145
20 39624x2x0,7526,0860160
20 4901x2x1,510,014060
20 4912x2x1,5 Quad11,019070
20 4922x2x1,514,523590
20 4934x2x1,517,0375105
20 4947x2x1,520,0545120
20 4958x2x1,521,5625130
20 49610x2x1,524,5760150
20 49712x2x1,525,5855155
20 49814x2x1,527,0960165
20 49919x2x1,531,01230190
View Complete Details

Fire Resistant Collectively Pair Screened I & C Cable

Fire Resistant Collectively Pair Screened I & C Cable 250V, which we offer, is the best owing to its varied features such as flame retardant, fire-resistant, halogen-free and low smoke emission. We offer these Fire Resistant Collectively and Pair Screened Instrumentation and Communication Cables at the market leading rates to the clients. Application : For fixed installation in most areas and on open deck in ships. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Highlights
  • Minimum recommended installation temperature -15 oC
  • Lowest operation temperature -40 oC
  • Identification : Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath
  • Core Identification
    • Each pair white - blue. Cores numbered 1, 2, 3, 4, 5.
    • The pairs are also covered by a numbered tape (1, 2, 3, 4, 5.)

Main Characteristics

Rated Voltage 150/250V (300V)
Maximum Conductor Temperature + 90oC
Flame Retardant IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables, category A
Fire Resistant IEC 60331-21
Halogen Free IEC 60754 series
Smoke Emission IEC 61034 series

Electrical Data

Parameters 0,75mm2 Unit
Loop resistance of pair, max. / +20oC 52 ohm/km
Pair capacitance, nom. / 800Hz 55 nF/km
Loop inductance, nom. 0,6 mH/km
Insulation resistance / +20oC ≥1500 Mohm*km.

Specifications

RFA-FRHF(i) 250VNumber of conductors & cross-section n x mm2Nominal outer diameter mmApproximate weight kg/kmMin. bending radius fixed installation mm
Part number
20 6672x2x0,7513,515585
20 6694x2x0,7515,524595
20 6717x2x0,7518,5380115
20 6738x2x0,7520,0430120
20 67510x2x0,7523,5545145
20 67712x2x0,7524,5625150
20 67914x2x0,7526,0725160
20 68319x2x0,7530,0945180
20 68524x2x0,7534,01205205
View Complete Details

Fire Resistant Screened I & C Cable

The company is the premium Manufacturer, Supplier and Exporter of the Fire Resistant Screened I & C Cable 250V. The company makes use of the latest technology while manufacturing the Fire Resistant Screened Instrumentation and Communication Cable. Fire Resistant Screened Instrumentation and Communication Cable can be availed, from us, at the market leading prices. Application : For fixed installation in most areas and on open deck in ships. If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended. Highlights
  • Minimum recommended installation temperature -15 oC
  • Lowest operation temperature -40 oC
  • Identification : Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath

Main Characteristics

Rated Voltage 150/250V (300V)
Maximum Conductor Temperature + 90oC
Flame Retardant IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables, category A
Fire Resistant IEC 60331-21
Halogen Free IEC 60754 series
Smoke Emission IEC 61034 series

Electrical Data

Parameters 0,75mm2 Unit
Loop resistance of pair, max. / +20oC 52 ohm/km
Pair capacitance, nom. / 800Hz 45 nF/km
Loop inductance, nom. 0,6 mH/km
Insulation resistance / +20oC ≥1500 Mohm*km.

Specifications

RFA-FRHF 250VNumber of conductors & cross-section n x mm2Nominal outer diameter mmApproximate weight kg/kmMin. bending radius fixed installation mm
Part number
20 6351x2x0,758,57555
20 6372x2x0,75 Quad10,012060
20 6392x2x0,7513,013580
20 6414x2x0,7515,521595
20 6437x2x0,7518,5330115
20 6458x2x0,7520,0380120
20 64710x2x0,7523,0480140
20 64912x2x0,7524,0545145
20 65114x2x0,7525,5620155
20 65519x2x0,7529,5805180
20 65724x2x0,7533,51030205
View Complete Details

Fire Resistant Screened Control And Instrumentation Cable

Fire Resistant Screened Control and Instrumentation Cable (250V), which we provide, is manufactured in confirmation to the established standards. We are rated amongst the reliable Manufacturers, Exporters and Suppliers of Fire Resistant Screened Control and Instrumentation Cable, located in New Delhi. Applications
  • For fixed installation in most areas and on open deck in ships, especially when lightweight cables are needed
  • If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended
Highlights
  • Minimum recommended installation temperature -15 oC
  • Lowest operation temperature -40 oC
  • Core Identification : black numbers on white base
  • Identification : Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath

Main Characteristics

Rated Voltage 150/250V (300V)
Maximum Conductor Temperature + 90oC
Flame Retardant IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables, category A
Fire Resistant IEC 60331-21 series
Halogen Free IEC 60754 series
Smoke Emission IEC 61034 series

Specifications

LKAM-FRHF 250VNumber of conductors & cross-section n x mm2Nominal outer diameter mmApproximate weight kg/kmCurrent rating AMin. bending radius fixed installation mm
Part number
224662x0,758,57011,350
224673x0,759,0859,855
224684x0,7510,01158,960
224695x0,7511,01358,365
224707x0,7511,51657,470
2247110x0,7515,02306,690
2247212x0,7515,52606,295
2247314x0,7516,53005,9100
2247416x0,7517,53405,6105
2247519x0,7518,03805,3110
2247724x0,7521,54804,9130
2247827x0,7522,05254,7130
2247932x0,7523,06204,5140
2248037x0,7525,07004,3150

View Complete Details

Fire Resistant Armoured Control And Instrumentation Cable

Fire Resistant Armoured Control and Instrumentation Cable (250V) is manufactured in confirmation to the set industrial standards. We offer these Fire Resistant Armoured Control and Instrumentation Cables at the market leading rates to the clients. We offer these Fire Resistant Armoured Control and Instrumentation Cables at reasonable rates. Applications
  • For fixed installation in most areas and on open deck in ships
  • If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended
Highlights
  • Minimum recommended installation temperature -15 oC
  • Lowest operation temperature -40 oC
  • Core Identification : black numbers on white base
  • Identification : Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath

Main Characteristics

Rated voltage 150/250V (300V)
Maximum conductor temperature + 90 oC
Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables, category A
Fire-resistant IEC 60331-21 series
Halogen-free IEC 60754 series
Smoke emission IEC 61034 series

Specification

LKSM-FRHF 0,6/1kVNumber ofconductors & cross-section n x mm2Crosssection of screen Mm2Nominal outer diameter MmApproximate weight kg/kmCurrent rating AMin. bending radius fixed installation Mm
Part number
22436 2x0,75 3,6 9,0 105 11,3 55
22437 3x0,75 3,9 10,0 135 9,8 60
22438 4x0,75 4,4 11,0 160 8,9 65
22439 5x0,75 4,9 11,5 185 8,3 70
22440 7x0,75 5,4 12,5 220 7,4 75
22441 10x0,75 11,6 16,0 350 6,6 95
22442 12x0,75 11,6 16,5 380 6,2 100
22443 14x0,75 11,7 17,5 415 5,9 105
22444 16x0,75 11,3 18,5 445 5,6 110
22445 19x0,75 11,9 19,5 505 5,3 115
22447 24x0,75 14,3 23,0 640 4,9 135
22448 27x0,75 14,6 23,5 685 4,7 140
22449 32x0,75 15,3 24,0 765 4,5 145
22450 37x0,75 16,7 26,0 870 4,3 155

View Complete Details

Fire Resistant Unarmoured Control And Instrumentation Cable

Fire Resistant Unarmoured Control and Instrumentation Cable (250V), which we offer, is manufactured using the best-grade materials. We are amongst the dependable Manufacturers, Suppliers and Exporters of Fire Resistant Unarmoured Control and Instrumentation Cable, based in New Delhi. These Fire Resistant Unarmoured Control and Instrumentation Cables can be purchased from us at the market leading rates. Applications
  • For fixed installation in most areas and on open deck in ships.
  • If the cable is exposed to direct sun light protective covering or cable with black outer sheath is recommended.
Highlights
  • Minimum recommended installation temperature -15 oC
  • Lowest operation temperature -40 oC
  • Core Identification : black numbers on white base
  • Identification : Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath

Main Characteristics

Rated voltage 150/250V (300V)
Maximum Conductor Temperature + 90oC
Flame Retardant IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables, category A
Fire Resistant IEC 60331-21 series
Halogen Free IEC 60754 series
Smoke Emission IEC 61034 series

Specifications

LKAM-HF 250VNumber of conductors & cross-section n x mm2Nominal outer diameter mmApproximate weight kg/kmCurrent rating AMin. bending radius fixed installation mm
Part number
224062x0,758,56511,335
224073x0,759,0809,835
224084x0,7510,01108,940
224095x0,7511,01308,345
224107x0,7511,51607,445
2241110x0,7515,02256,660
2241212x0,7515,52556,260
2241314x0,7516,52955,965
2241416x0,7517,53305,670
2241519x0,7518,03755,375
2241724x0,7521,54754,985
2241827x0,7522,05204,785
2241932x0,7523,06154,590
2242037x0,7525,06954,3100

View Complete Details

Armoured Control And Instrumentation Cable

Alankar Cable Industries is counted amidst the top names in the industry, when it comes to buying a reliable range of Underground Armoured Cables. The company is known as a dynamic Control and Instrumentation Cable Manufacturer, Exporter, and Supplier from New Delhi (India). Manufactured from the premium raw materials, our Underground Armoured Cables perform well under adverse conditions. These Underground Armoured Cables work for longer time than ordinary cables and are safe to use. The Underground Armoured Cables are offered by us in varied specifications, at the most competitive prices. Applications
  • For fixed installation in most areas and on open deck in ships.
  • If the cable is exposed to direct sun light protective covering orcable with black outer sheath is recommended
Highlights
  • Minimum recommended installation temperature -15 oC
  • Lowest operation temperature -40 oC
  • Core Identification : black numbers on white base
  • Identification : Lot number, cable type, cable size, voltage, temperature, standards, production month, manufacturer's name and meter marking printed on the sheath

Main Characteristics

Rated voltage 150/250V (300V)
Maximum conductor temperature + 90 oC
Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable
IEC 60332-3-22 -test for bunched wires and cables, category A
Halogen-free IEC 60754 series
Smoke emission IEC 61034 series

Specification

LKSM-FRHF 0,6/1kVNumber of conductors & cross-section n x mm2Crosssection of screen mm2Nominal outer diameter MmApproximate weight kg/kmCurrent rating AMin. bending radius fixed installation Mm
Part number
26402 2x0,75 3,6 7,5 90 11,3 45
26403 3x0,75 3,6 8,0 100 9,8 50
26404 4x0,75 3,6 8,5 110 8,9 50
26405 5x0,75 4,1 9,5 140 8,3 55
26407 7x0,75 4,1 10,0 160 7,4 60
26410 10x0,75 5,1 12,5 220 6,6 70
26412 12x0,75 5,3 13,0 240 6,2 75
26414 14x0,75 5,6 13,5 265 5,9 75
26416 16x0,75 6,1 14,0 295 5,6 80
26419 19x0,75 8,7 14,5 330 5,3 85
26424 24x0,75 11,7 17,5 450 4,9 100
26427 27x0,75 11,7 17,5 480 4,7 100
26432 32x0,75 11,8 18,5 540 4,5 105
26437 37x0,75 11,9 19,5 600 4,3 115

View Complete Details

Jz-500 Hmh Halogen Free Control Cable

  • Min. Order (MOQ) 1000 Meter
  • Brand Name ALANKAR / ALANCAB
  • HALOGEN FREE
  • LEAD FREE
We are offering jz-500 hmh halogen free control cable. jz-hmh control cablehalogen-free flexible control cable, core construction adapted to din vde 0281 part 14 and din vde 0281 part 13temperature rangeflexing -15c to +70cfixed installation -40c to +70cnominal voltage u0/u 300/500 vtest voltage 2000 vminimum bending radiusflexing approx. 12, 5x cable fixed installation approx. 4x cable .

Additional Information:

Payment Terms : L/C, T/T

Packaging Details : WOODEN DRUMS OR CORRUGATED BOXES

Delivery Time : ONE MONTH IN INDIA/PORT

View Complete Details

Rdh(st)h Halogen Free Instrumentation Cable

  • Min. Order (MOQ) 1000 Meter
  • Brand Name ALANKAR / ALANCAB
  • HALOGEN FREE
  • LEAD FREE
We are offering rdh(st)h halogen free instrumentation cable. Rdh (st) h installation cablehalogen-free data transmission cable adapted to din vde 0815conductor resistancemax. 73.6 ohm/km (0.5 mm)max. 36.8 ohm/km (1.0 mm)temperature rangeflexing -5c to +50c (+23f to +122f)fixed installation to +70c/+158fnominal voltage max. 225 vtest voltageconductor/conductor 500 vconductor/shield 2000 vinsulation resistancemin. 100 mohm x kmmutual capacitanceat 800 hz max. 100 nf/km(this value may be exceeded by 20% with a make-up up to 4 pairs) impedance at 1 khz (nominal values)450 ohm (0.5 mm)320 ohm (1.0 mm)capacity unbalanceat 800 hz max. 200 pf/100 m(20% of the values, but one value up to 200 pf is allowed)cross-talk attenuationat min. 10 khz, 60 db/500 mline attenuation at 1 khz (nominal values)1.2 db/km (0.5 mm)0.9 db/km (1.0 mm)bending radiusapprox. 7.5x cable bare copper stranded wires 0.5 mm (7x0.3) or 1.0 mm (7x0.43)conductor insulation, halogen-free polymer compoundconductors twisted in pairs, with short lay-length(approx. 20 pitch/m 50 mm)4 pairs stranded to a unitholding tape units with number codingunits stranded in concentric layersconductor wrappingelectrostatic shield of plastic coated aluminum foil and drain wire tinned, 0.5 mmouter jacket, halogen-free, polymer compound, flame resistantcolor: grayconductor colorspair no./a-conductor/b-conductor1/blue/red2/grey/yellow3/green/brown4/white/black(4 pairs 1 unit)application the halogen-free data transmission cable rd-h(st)h are used for measurement and control technology for transmission of analog and digital signals up to frequencies of approx. 10 khz. The twisted pairs with short pitches.

Additional Information:

Payment Terms : L/C

Packaging Details : WOODEN DRUMS OR CORRUGATED BOXES

Delivery Time : ONE MONTH IN INDIA/PORT

View Complete Details

Rz 1k Halogen Free Energy Cable

  • Min. Order (MOQ) 1000 Meter
  • Brand Name ALANKAR / ALANCAB
  • HALOGEN FREE
  • LEAD FREE
  • CONDUCTOR FLEXIBLE
We are offering rz 1k halogen free energy cable. halogen-free flexible power cable, core construction adapted to din vde 0281 part 14 and din vde 0281 part 13temperature rangeflexing -15c to +70cfixed installation -40c to +70cnominal voltage u0/u 1000 vtest voltage 3000 vminimum bending radiusflexing approx. 12, 5x cable fixed installation approx. 4x cable .

Additional Information:

Payment Terms : L/C, T/T

Packaging Details : WOODEN DRUMS OR CORRUGATED BOXES

Delivery Time : ONE MONTH IN INDIA/PORT

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us