Post Buy Requirement
Ajit Electronics Corporation
Dombivali East, Maharashtra, India
gstGST : 27ABVPN8572E1ZY Verified Add Review

Other Products / Services #5418094

Current Injection Set

  • Min. Order (MOQ) 1 Piece

Features :

  • Built in µc based Time Interval Meter measuring from1 millisec to 9999 sec.
  • Panel with easy and clear legends to read.
  • Continuosly variable outputs.
  • Auto Cut-off & output isolated.
  • Self sensing of contacts i.e. NO or NC
  • Potential free star stop signals
  • Available in Portable / Lab type models with metal cover

Specifications

Model Current Output AC No. of Units Metering
AEP - 1 1000 A / 2 V 500 A / 4V 250A / 8V   Single Unit a) 3 1/2 Digit, Digital ammeter OR
b) Analog ammeter with multiplying factor
AEP - 2 1000 A / 5 V 500 A / 10V 250A / 20V   Two units.
A) Transformer
B) Control unit
AEP - 3 2000 A / 2 V 1000 A / 4V 500A / 8V
AEP - 4 2000 A / 4V 1000 A / 8V 500A / 16V
AEP - 5 3000 A / 2 V 1500 A / 4V 750A / 8V
AEP - 6 4000 A / 2 V 2000 A / 4V 1000A / 8V     Three units.
A) Transformer unit
B) Control unit
C) Dimmer unit.
AEP - 7 5000 A / 2 V 2500 A / 4V 1250A / 8V






View Complete Details

Variable Three Phase Shifter

This instrument is capable of producing 3 Phase AC Voltage with phase shifting arrangement between the phases simultaneously.Voltage OutputRange : 0 to 415V ph-ph variable.Measurement : 3 Digit Digital voltmeter with selector switchPhase Angle Setting : With the help of selector switches and a variac.Angle Measurement : Switch positions and a digital meterIndications : LED indicators for input and outputProtection : Glass fuses in the input supply and output.Power Supply : Three Phase, 415V AC 50 Hz, 120 degree apartCabinet : Powder Coated sheet metal cabinet.

Model Current Output AC No. of Units Metering
AEP - 1 1000 A / 2 V 500 A / 4V 250A / 8V   Single Unit a) 3 1/2 Digit, Digital ammeter OR
b) Analog ammeter with multiplying factor
AEP - 2 1000 A / 5 V 500 A / 10V 250A / 20V   Two units.
A) Transformer
B) Control unit
AEP - 3 2000 A / 2 V 1000 A / 4V 500A / 8V
AEP - 4 2000 A / 4V 1000 A / 8V 500A / 16V
AEP - 5 3000 A / 2 V 1500 A / 4V 750A / 8V
AEP - 6 4000 A / 2 V 2000 A / 4V 1000A / 8V     Three units.
A) Transformer unit
B) Control unit
C) Dimmer unit.
AEP - 7 5000 A / 2 V 2500 A / 4V 1250A / 8V






View Complete Details

High Voltage Tester

APPLICATIONS

  • For High Voltage withstand, breakdown testing of electrical insulating systems.
  • For Dielectric Strength testing of electrical / electronic components, small appliances, tools, motors, machines etc.


FEATURES

  • Compact & Simple to Operate
  • Zero Interlock for H.V. Output
  • Analog or Digital read outs
  • Adjustable, selectable leakage current.
  • Audio visual indication for presence of high voltage
  • Continuosly variable test voltage
  • Highly sensitive electronics circuit for tripping
  • Avaliabe in AC, DC as well as AC & DC Combined
  • Outputs upto 100KV.
  • Available with built - in printer and or /RS 232 interface.
  • H.V. Test sets of other specifications as per requirement can be supplied.


AUTOMATIC VERSIONFollowing parameters can be set by 4x4 matrix keypadA) Output Test VoltageB) Leakage / Trip Current LimitC) Test Duration (Time)HV built in printer, with Rs232 interface & with both the feature are considered as Automatic version HV test set. In Automatic HV Test Set both types like with AC output & with DC output instruments are available.

SEMI AUTOMATIC VERSIONFollowing parameters can be set by push button with potentiometer / thumb wheel switch.A) Output Test VoltageB) Leakage / Trip Current LimitC) Test Duration (Time)

  • Once above parameters set and the high voltage is started the instrument will automatically raise the voltage.
  • On reaching of the test voltage, control circuit will start to command to timer. After completion of duration motor will come back.
  • Object Test Fail Indication is given.

Specifications

Sr. No. Model No. O/P Voltage Trip Current
1 HV.1 0 To 5Kv 30mA
2 HV.2 0 To 5Kv 100mA
3 HV.3 0 To 10kV 30mA
4 HV.4 0 To 10kV 100mA
5 HV.5 0 To 20Kv 30mA
6 HV.6 0 To 20Kv 100mA
7 HV.7 0 TO 30 Kv 20mA
8 HV.8 0 To 30 Kv 100mA
9 HV.9 0 To 50 kv 20mA
10 HV.10 0 To 50 kv 50mA
11 HV.11 0 To 50Kv 100mA
12 HV.12 0 To 60Kv 50mA
13 HV.13 0 To 60kV 75mA
14 HV.14 0 To 60kV 100mA
15 HV.15 0 To 75Kv 50mA
16 HV.16 0 To 75Kv 75mA
17 HV.17 0 To 75 Kv 100mA
18 HV.18 0 To 100 Kv 50mA
19 HV.19 0 To 100 kv 75mA
20 HV.20 0 To 100 kv 100mA

ORDERING INFORMATION

Output Analog Meters Analog Meters with Digital Timer Digital Meters Digital Meters with Digital Timer Digital Meters with built in Printer Digital Meters with RS232 interface Digital meters with printer & RS232 interface Semi Automatic
AC HV # HV # T HV # DIGI HV # T DIGI HV # P HV # RS HV # PRS HV # SEMI
DC - - HV # D HV # D T HV # D P HV # D RS HV # D P RS HV # D SEMI
AC/DC Combined - - HV # AD HV # AD T HV # AD P HV # AD RS HV # AD P RS HV # A D SEMI
View Complete Details

Double Frequency Generator

  • Min. Order (MOQ) 1 Piece

MOTOR GENERATOR UNITThis test setup is generally used to perform induced voltage test on the transformers. This set up consists of the USED motor and generator combination to develop the required voltage and frequency. Both generating unit and the drive motor are mounted on a common metallic frame.

GENERATING UNIT

  • Input : 0 to 415 V three phase, 50 Hz through the dimmer unit.
  • Output : 50 to 900 V three phase, 100 Hz.
  • Capacity : Suitable to test the distribution transformers
  • Transformers KVA ratings shall be specified by the customer.

The input and output are terminated on the suitable terminals on the unit.Make : KIRLOSKAR / CROMPTON / AEC / SIEMENS / NGEF (or eQUIVALENT)

DRIVING UNIT

  • Input : 415 V three phase, 50 Hz through the dol /star delta starter.
  • RPM : 1440 or any suitable speed (or eQUIVALENT)
  • The input supply terminals are terminated on the suitable terminals on the unit.
  • Make : KIRLOSKAR / CROMPTON / AEC / SIEMENS / NGEF (or eQUIVALENT)
View Complete Details

Transformer Oil Tester

AJIT Transformer Oil Set is completely self contained, compact & portable unit giving smooth variable output voltage from zero to 60/80/100KV for testing the dielectric strength of insulating oil.
The set has been specially designed for the testing the die electric breakdown Voltage of insulating liquids.

Features :

  • Manual or Motorised Version.
  • Highly Sensitive Electronics Circuit Breaker
  • Heavy Duty H.V. Transformer (Epoxy Cast)
  • Tried, Proven & Tested design.
  • Zero Interlock for output.
  • Door Micro s/w for operator’s safety.
  • Digital or Analog KV Meters.

The oil cups are made of Acrylic & have removable electrodes for easy cleaning & polishing. The unique design of the lectrode holders eliminate oil leakages around shafts.

ACCESSORIES SUPPLIED WITH EACH SET :1. OIL CUP WITH ONE SET OF ELECTRODES.2. ONSE SET OF GO/NO-GO GAUGES3. ONE SET OF INSTRUCTION MANUAL.

SAFETYMaximum possible safety of the operator as well as the equipment is ensured by a safety conscious design. The voltage controller is inter locked at its minimum position so that H.V. can be switched ON only when the voltage controller is brought to zero after every test or interruption. The acrylic door leading to H.V. Terminals has a micro switch fitted so that opening of the acrylic door shuts the H.V. OFF.

APPLICATIONAJIT oil set is completely self contained, compact & portable unit giving smooth variable output voltage from zero to 60/80/100KV for testing the dielectric strength of insulating oil. The set has been specially designed for testing the dielectric breakdown Voltage of insulating liquids as per the directions mentioned in IS 6792.

OIL CELLThe oil cells are made of Acrylic & have removable electrodes for easy cleaning & polishing. The unique design of the electrode holders eliminate oil leakages around shafts.

ACCESSORIES SUPPLIED WITH EACH SET :

  • One set of instruction manual
  • Oil Cell with one set of electrodes
  • One set of GO/NO-GO Gauges

Specifications

MODEL INPUT OUTPUT ACCURACY RATE OF RISE OF VOLTAGE [approximately] DIMENSIONS LXBXH
A/60 220/250V 10%, ± 50Hz 0-60 KV ±4% of full Scale Manual 55x35x42 cm Approx.
A/80 0-80 KV 70x40x48 cm Approx.
A/100 0-100 KV 70x40x48 cm Approx.
A/60M 0-60 KV Automatic 2 KV/Sec.(Motorised) 55x35x42 cm Approx.
A/80M 0-80 KV 70x40x48 cm Approx.
A/100 M 0-100 KV 70x40x48 cm Approx.
View Complete Details

Automatic Relay Tester

Features :

  • Potential -Free start and stop signal
  • Continously adjustable outputs
  • Portable Models
  • Automatic Self Sensing of Contacts, i.e. NO /NC
  • Digital ammeter, voltmeter and time interval meter (UniTimer)
  • UniTimer automatically puts OFF the output, when timer reaches to its maximum value of the selected range to ensure safety of the instruments as well as the item under test. Wide range of measurement, i.e. from 1 millisecond.
  • To 9999 secs In four ranges.


APPLICATIONSThe protective devices such as relays, overload coils, circuit breakers must be checked regularly to ensure that, they are always ready to operate correctly. If a fault occurs in the equipment, which they are protecting, routine relay testing will quickly detect the faulty, incorrectly adjusted protection circuits correctly. It is usually necessary to measure its operating time. The micro controller based time interval meter is used for this purpose in all AJIT brand relay testers.

 

Technical Specifications :Input Supply : 230V, AC, + 10% single phase.Metering : a) 3 ½ digit, ammeter / voltmeter b) micro controlled based time interval meterRange : 0-9.999 - 99.99 - 999.9-9999 sec selectable by a push button.Display : 4 digit LED Type.Protection : Fuse /MCB, Over current protection.

Specifications

MODEL AC Current
O/P-I
AC Current
O/P-II
AC Voltage
O/P
DC Voltage
O/P
Aux. Voltage
RTS - 1 0-1A - 5A - 250V - 250V
RTS - 25 0 - 2.5A - 25A - - 250V
RTS - 25AV 0 - 2.5A - 25A - 250V - 250V
RTS 50 0-1A-10A-50 - 250V 250V 250V
AE 1 500 VA 0-1A-10A-100A - 250V - 250V
AE 1-2 VAD 0-1A-10-100A 0-10A 250V 250V 250V
AE 2 AVD 0-1A-10-200A - 250V 250V 250V
AE 1 500 VAD 0-1A-10-100A - 250V 250V 250V
AE 100 Automatic with CT test functionand built in printer 0-1A-10-100A 0-10A 500V 300V 250V




View Complete Details

Transformer Test Panel

  • Min. Order (MOQ) 1 Piece
  • Type Automatic
  • Voltage 220V
  • Frequency 50 Hz
  • Power 3-6kw
  • Driven Type Electric
  • Phase Double Phase
  • Warranty 1 Year

APPLICATION :This is a common test panel for distribution/ power transformers of different specifications. The user can perform most of the factory tests, as per the relevant IS standard for the transformers. The panel consists of power analyser, meters for high voltage test, meters for induced voltage test etc, control for all the tests, protection and interlock circuits so that a single panel can be used to conduct a number of tests using only one dimmerstat and the associated devices
FEATURES :

  • A single measurement and control center.
  • Simple & Easy to use.
  • All digital & accurate meters.
  • Electrically interlocked for safe operation.
  • Wide range of transformers can be tested.

Following Tests can be conducted :

  • Induced voltage test using DVDF motor generator setup, dimmer & common panel.
  • High voltage test using HV transformer, dimmer & common panel.
  • Open circuit and short circuit test using common panel, dimmerstat & intermediate transformer (if required & offered).
  • Magnetic balance tests using dimmer & common panel.


MOTOR GENERTOR SET FOR DVDF :Motor Generator set made from the used and rewound motors fitted on a common metallic frame and coupled together.

Technical specifications :
Generating unit :

  • Input : 0 to 415 V three phase, 50 Hz through the dimmer unit.
  • Output : 50 to 900 V three phase, 100 Hz or 150 Hz as per customers specifications.
  • Capacity : Suitable to test the distribution transformers. Transformers KVA ratings shall be specified by the customer.
  • The input and output are terminated on the suitable terminals on the unit.
  • Make : KIRLOSKAR / CROMPTON / AEC / SIEMENS / NGEF (or any other equivalent ).


Driving unit :

  • Input : 415 V three phase, 50 Hz through a starter.
  • RPM : 1440 or any other suitable speed.
  • The input supply terminals are terminated on the suitable terminals on the unit.
  • Make : KIRLOSKAR / CROMPTON / AEC / SIEMENS / NGEF (or any other equivalent).


VARIABLE 3 PH MOTORIZED AUTOTRANSFORMER (DIMMER-STAT) :
Technical specifications :

  • Cooling type :- Air Cooled/ Oil Cooled Type.
  • Input :- 415 V 3 phase, 50 Hz.
  • Output :- 0 470 V 3 phase, 50 Hz, variable.
  • Operation :- Motor driven for increase and decrease. The motor control push buttons will be in the common panel.
  • Current capacity :- Selected depending upon the kVA rating of transformer under test.
  • Termination :- Input, Signals, Motor wires & Output are terminated on insulated terminals with appropriate legend marking.
  • The dimmer :- stat will have caster wheels to make it portable.
  • Housing :- The dimmer-stat will be housed in powder coated sheet metal cabinet.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

List of Other Products by Ajit Electronics Corporation from Dombivali East, Maharashtra.
Post Buy Requirement
Ajit Electronics Corporation
gstGST : 27ABVPN8572E1ZY Verified Add Review

Our Products

  1. Testing Equipment 6 Products available
  2. Measuring Instruments & Equipment 3 Products available
  3. Domestic Fans, AC & Coolers

    2 Products available
  4. Electrical & Electronic Testing Devices

    1 Products available
  5. Testing Equipments

    1 Products available
  6. Electric Control Panels

    1 Products available
  7. Fuses, Circuit Breakers & Components

    1 Products available
  8. Others Products 1 Products available

Other Products / Services

We offer the best product range of Variable Three Phase Shifter.

Current Injection Set

  • Min. Order (MOQ) 1 Piece

Features :

  • Built in µc based Time Interval Meter measuring from1 millisec to 9999 sec.
  • Panel with easy and clear legends to read.
  • Continuosly variable outputs.
  • Auto Cut-off & output isolated.
  • Self sensing of contacts i.e. NO or NC
  • Potential free star stop signals
  • Available in Portable / Lab type models with metal cover

Specifications

Model Current Output AC No. of Units Metering
AEP - 1 1000 A / 2 V 500 A / 4V 250A / 8V   Single Unit a) 3 1/2 Digit, Digital ammeter OR
b) Analog ammeter with multiplying factor
AEP - 2 1000 A / 5 V 500 A / 10V 250A / 20V   Two units.
A) Transformer
B) Control unit
AEP - 3 2000 A / 2 V 1000 A / 4V 500A / 8V
AEP - 4 2000 A / 4V 1000 A / 8V 500A / 16V
AEP - 5 3000 A / 2 V 1500 A / 4V 750A / 8V
AEP - 6 4000 A / 2 V 2000 A / 4V 1000A / 8V     Three units.
A) Transformer unit
B) Control unit
C) Dimmer unit.
AEP - 7 5000 A / 2 V 2500 A / 4V 1250A / 8V






View Complete Details

Variable Three Phase Shifter

This instrument is capable of producing 3 Phase AC Voltage with phase shifting arrangement between the phases simultaneously.Voltage OutputRange : 0 to 415V ph-ph variable.Measurement : 3 Digit Digital voltmeter with selector switchPhase Angle Setting : With the help of selector switches and a variac.Angle Measurement : Switch positions and a digital meterIndications : LED indicators for input and outputProtection : Glass fuses in the input supply and output.Power Supply : Three Phase, 415V AC 50 Hz, 120 degree apartCabinet : Powder Coated sheet metal cabinet.

Model Current Output AC No. of Units Metering
AEP - 1 1000 A / 2 V 500 A / 4V 250A / 8V   Single Unit a) 3 1/2 Digit, Digital ammeter OR
b) Analog ammeter with multiplying factor
AEP - 2 1000 A / 5 V 500 A / 10V 250A / 20V   Two units.
A) Transformer
B) Control unit
AEP - 3 2000 A / 2 V 1000 A / 4V 500A / 8V
AEP - 4 2000 A / 4V 1000 A / 8V 500A / 16V
AEP - 5 3000 A / 2 V 1500 A / 4V 750A / 8V
AEP - 6 4000 A / 2 V 2000 A / 4V 1000A / 8V     Three units.
A) Transformer unit
B) Control unit
C) Dimmer unit.
AEP - 7 5000 A / 2 V 2500 A / 4V 1250A / 8V






View Complete Details

High Voltage Tester

APPLICATIONS

  • For High Voltage withstand, breakdown testing of electrical insulating systems.
  • For Dielectric Strength testing of electrical / electronic components, small appliances, tools, motors, machines etc.


FEATURES

  • Compact & Simple to Operate
  • Zero Interlock for H.V. Output
  • Analog or Digital read outs
  • Adjustable, selectable leakage current.
  • Audio visual indication for presence of high voltage
  • Continuosly variable test voltage
  • Highly sensitive electronics circuit for tripping
  • Avaliabe in AC, DC as well as AC & DC Combined
  • Outputs upto 100KV.
  • Available with built - in printer and or /RS 232 interface.
  • H.V. Test sets of other specifications as per requirement can be supplied.


AUTOMATIC VERSIONFollowing parameters can be set by 4x4 matrix keypadA) Output Test VoltageB) Leakage / Trip Current LimitC) Test Duration (Time)HV built in printer, with Rs232 interface & with both the feature are considered as Automatic version HV test set. In Automatic HV Test Set both types like with AC output & with DC output instruments are available.

SEMI AUTOMATIC VERSIONFollowing parameters can be set by push button with potentiometer / thumb wheel switch.A) Output Test VoltageB) Leakage / Trip Current LimitC) Test Duration (Time)

  • Once above parameters set and the high voltage is started the instrument will automatically raise the voltage.
  • On reaching of the test voltage, control circuit will start to command to timer. After completion of duration motor will come back.
  • Object Test Fail Indication is given.

Specifications

Sr. No. Model No. O/P Voltage Trip Current
1 HV.1 0 To 5Kv 30mA
2 HV.2 0 To 5Kv 100mA
3 HV.3 0 To 10kV 30mA
4 HV.4 0 To 10kV 100mA
5 HV.5 0 To 20Kv 30mA
6 HV.6 0 To 20Kv 100mA
7 HV.7 0 TO 30 Kv 20mA
8 HV.8 0 To 30 Kv 100mA
9 HV.9 0 To 50 kv 20mA
10 HV.10 0 To 50 kv 50mA
11 HV.11 0 To 50Kv 100mA
12 HV.12 0 To 60Kv 50mA
13 HV.13 0 To 60kV 75mA
14 HV.14 0 To 60kV 100mA
15 HV.15 0 To 75Kv 50mA
16 HV.16 0 To 75Kv 75mA
17 HV.17 0 To 75 Kv 100mA
18 HV.18 0 To 100 Kv 50mA
19 HV.19 0 To 100 kv 75mA
20 HV.20 0 To 100 kv 100mA

ORDERING INFORMATION

Output Analog Meters Analog Meters with Digital Timer Digital Meters Digital Meters with Digital Timer Digital Meters with built in Printer Digital Meters with RS232 interface Digital meters with printer & RS232 interface Semi Automatic
AC HV # HV # T HV # DIGI HV # T DIGI HV # P HV # RS HV # PRS HV # SEMI
DC - - HV # D HV # D T HV # D P HV # D RS HV # D P RS HV # D SEMI
AC/DC Combined - - HV # AD HV # AD T HV # AD P HV # AD RS HV # AD P RS HV # A D SEMI
View Complete Details

Double Frequency Generator

  • Min. Order (MOQ) 1 Piece

MOTOR GENERATOR UNITThis test setup is generally used to perform induced voltage test on the transformers. This set up consists of the USED motor and generator combination to develop the required voltage and frequency. Both generating unit and the drive motor are mounted on a common metallic frame.

GENERATING UNIT

  • Input : 0 to 415 V three phase, 50 Hz through the dimmer unit.
  • Output : 50 to 900 V three phase, 100 Hz.
  • Capacity : Suitable to test the distribution transformers
  • Transformers KVA ratings shall be specified by the customer.

The input and output are terminated on the suitable terminals on the unit.Make : KIRLOSKAR / CROMPTON / AEC / SIEMENS / NGEF (or eQUIVALENT)

DRIVING UNIT

  • Input : 415 V three phase, 50 Hz through the dol /star delta starter.
  • RPM : 1440 or any suitable speed (or eQUIVALENT)
  • The input supply terminals are terminated on the suitable terminals on the unit.
  • Make : KIRLOSKAR / CROMPTON / AEC / SIEMENS / NGEF (or eQUIVALENT)
View Complete Details

Transformer Oil Tester

AJIT Transformer Oil Set is completely self contained, compact & portable unit giving smooth variable output voltage from zero to 60/80/100KV for testing the dielectric strength of insulating oil.
The set has been specially designed for the testing the die electric breakdown Voltage of insulating liquids.

Features :

  • Manual or Motorised Version.
  • Highly Sensitive Electronics Circuit Breaker
  • Heavy Duty H.V. Transformer (Epoxy Cast)
  • Tried, Proven & Tested design.
  • Zero Interlock for output.
  • Door Micro s/w for operator’s safety.
  • Digital or Analog KV Meters.

The oil cups are made of Acrylic & have removable electrodes for easy cleaning & polishing. The unique design of the lectrode holders eliminate oil leakages around shafts.

ACCESSORIES SUPPLIED WITH EACH SET :1. OIL CUP WITH ONE SET OF ELECTRODES.2. ONSE SET OF GO/NO-GO GAUGES3. ONE SET OF INSTRUCTION MANUAL.

SAFETYMaximum possible safety of the operator as well as the equipment is ensured by a safety conscious design. The voltage controller is inter locked at its minimum position so that H.V. can be switched ON only when the voltage controller is brought to zero after every test or interruption. The acrylic door leading to H.V. Terminals has a micro switch fitted so that opening of the acrylic door shuts the H.V. OFF.

APPLICATIONAJIT oil set is completely self contained, compact & portable unit giving smooth variable output voltage from zero to 60/80/100KV for testing the dielectric strength of insulating oil. The set has been specially designed for testing the dielectric breakdown Voltage of insulating liquids as per the directions mentioned in IS 6792.

OIL CELLThe oil cells are made of Acrylic & have removable electrodes for easy cleaning & polishing. The unique design of the electrode holders eliminate oil leakages around shafts.

ACCESSORIES SUPPLIED WITH EACH SET :

  • One set of instruction manual
  • Oil Cell with one set of electrodes
  • One set of GO/NO-GO Gauges

Specifications

MODEL INPUT OUTPUT ACCURACY RATE OF RISE OF VOLTAGE [approximately] DIMENSIONS LXBXH
A/60 220/250V 10%, ± 50Hz 0-60 KV ±4% of full Scale Manual 55x35x42 cm Approx.
A/80 0-80 KV 70x40x48 cm Approx.
A/100 0-100 KV 70x40x48 cm Approx.
A/60M 0-60 KV Automatic 2 KV/Sec.(Motorised) 55x35x42 cm Approx.
A/80M 0-80 KV 70x40x48 cm Approx.
A/100 M 0-100 KV 70x40x48 cm Approx.
View Complete Details

Automatic Relay Tester

Features :

  • Potential -Free start and stop signal
  • Continously adjustable outputs
  • Portable Models
  • Automatic Self Sensing of Contacts, i.e. NO /NC
  • Digital ammeter, voltmeter and time interval meter (UniTimer)
  • UniTimer automatically puts OFF the output, when timer reaches to its maximum value of the selected range to ensure safety of the instruments as well as the item under test. Wide range of measurement, i.e. from 1 millisecond.
  • To 9999 secs In four ranges.


APPLICATIONSThe protective devices such as relays, overload coils, circuit breakers must be checked regularly to ensure that, they are always ready to operate correctly. If a fault occurs in the equipment, which they are protecting, routine relay testing will quickly detect the faulty, incorrectly adjusted protection circuits correctly. It is usually necessary to measure its operating time. The micro controller based time interval meter is used for this purpose in all AJIT brand relay testers.

 

Technical Specifications :Input Supply : 230V, AC, + 10% single phase.Metering : a) 3 ½ digit, ammeter / voltmeter b) micro controlled based time interval meterRange : 0-9.999 - 99.99 - 999.9-9999 sec selectable by a push button.Display : 4 digit LED Type.Protection : Fuse /MCB, Over current protection.

Specifications

MODEL AC Current
O/P-I
AC Current
O/P-II
AC Voltage
O/P
DC Voltage
O/P
Aux. Voltage
RTS - 1 0-1A - 5A - 250V - 250V
RTS - 25 0 - 2.5A - 25A - - 250V
RTS - 25AV 0 - 2.5A - 25A - 250V - 250V
RTS 50 0-1A-10A-50 - 250V 250V 250V
AE 1 500 VA 0-1A-10A-100A - 250V - 250V
AE 1-2 VAD 0-1A-10-100A 0-10A 250V 250V 250V
AE 2 AVD 0-1A-10-200A - 250V 250V 250V
AE 1 500 VAD 0-1A-10-100A - 250V 250V 250V
AE 100 Automatic with CT test functionand built in printer 0-1A-10-100A 0-10A 500V 300V 250V




View Complete Details

Transformer Test Panel

  • Min. Order (MOQ) 1 Piece
  • Type Automatic
  • Voltage 220V
  • Frequency 50 Hz
  • Power 3-6kw
  • Driven Type Electric
  • Phase Double Phase
  • Warranty 1 Year

APPLICATION :This is a common test panel for distribution/ power transformers of different specifications. The user can perform most of the factory tests, as per the relevant IS standard for the transformers. The panel consists of power analyser, meters for high voltage test, meters for induced voltage test etc, control for all the tests, protection and interlock circuits so that a single panel can be used to conduct a number of tests using only one dimmerstat and the associated devices
FEATURES :

  • A single measurement and control center.
  • Simple & Easy to use.
  • All digital & accurate meters.
  • Electrically interlocked for safe operation.
  • Wide range of transformers can be tested.

Following Tests can be conducted :

  • Induced voltage test using DVDF motor generator setup, dimmer & common panel.
  • High voltage test using HV transformer, dimmer & common panel.
  • Open circuit and short circuit test using common panel, dimmerstat & intermediate transformer (if required & offered).
  • Magnetic balance tests using dimmer & common panel.


MOTOR GENERTOR SET FOR DVDF :Motor Generator set made from the used and rewound motors fitted on a common metallic frame and coupled together.

Technical specifications :
Generating unit :

  • Input : 0 to 415 V three phase, 50 Hz through the dimmer unit.
  • Output : 50 to 900 V three phase, 100 Hz or 150 Hz as per customers specifications.
  • Capacity : Suitable to test the distribution transformers. Transformers KVA ratings shall be specified by the customer.
  • The input and output are terminated on the suitable terminals on the unit.
  • Make : KIRLOSKAR / CROMPTON / AEC / SIEMENS / NGEF (or any other equivalent ).


Driving unit :

  • Input : 415 V three phase, 50 Hz through a starter.
  • RPM : 1440 or any other suitable speed.
  • The input supply terminals are terminated on the suitable terminals on the unit.
  • Make : KIRLOSKAR / CROMPTON / AEC / SIEMENS / NGEF (or any other equivalent).


VARIABLE 3 PH MOTORIZED AUTOTRANSFORMER (DIMMER-STAT) :
Technical specifications :

  • Cooling type :- Air Cooled/ Oil Cooled Type.
  • Input :- 415 V 3 phase, 50 Hz.
  • Output :- 0 470 V 3 phase, 50 Hz, variable.
  • Operation :- Motor driven for increase and decrease. The motor control push buttons will be in the common panel.
  • Current capacity :- Selected depending upon the kVA rating of transformer under test.
  • Termination :- Input, Signals, Motor wires & Output are terminated on insulated terminals with appropriate legend marking.
  • The dimmer :- stat will have caster wheels to make it portable.
  • Housing :- The dimmer-stat will be housed in powder coated sheet metal cabinet.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us