Drive Panel

  • Type Manual VFD Panel Auto VFD Panel
  • Application Modulated type load Process plant Treatment plant Motor-driven machinery
  • Construction Type Compartmentalize Non- Compartmentalize/Cubical
  • Max. rated of VFD 400KW
  • Rated operated voltage 440V
  • Degree of Protection Up to IP54
  • Ambient temp Design Ambient temp. standard 40°C Operated 45°C & 50°C
  • Inspection and Testing Routine Test Control/Interlock Test Continuity Test Mechanical endurance Test
  • Fabrication Ms Crca Sheet Steel or Ss304 Structure, Door, Cover: 1.6 Mm Thick Gland Plate: 3mm Thick
  • Component selection Drive selection basis on their rating and application, input choke and output choke selection basis
  • Feature Manufacturers across the globe capitalize on AC variable frequency drive technology to save money

When a VFD starts a motor, it initially applies a low frequency and voltage to the motor. The starting frequency is typically 2 Hz or less. Starting at such a low frequency avoids the high inrush current that occurs when a motor is started by simply applying the utility (mains) voltage by turning on a switch. When VFD starts, the applied frequency and voltage are increased at a controlled rate or ramped up to accelerate the load without drawing excessive current.

This starting method typically allows a motor to develop 150% of its rated torque while drawing only 50% of its rated current. When a motor is simply switched on at full voltage, it initially draws at least 300% of its rated current while producing less than 50% of its rated torque. As the load accelerates, the available torque usually drops a little and then rises to a peak while the current remains very high until the motor approaches full speed. A VFD can be adjusted to produce a steady 150% starting torque from standstill right up to full speed while drawing only 50% current.

Additional Information:

Payment Terms : T/T

View Complete Details

Plc Panel

  • Application process plant Machinery Treatment plant
  • Construction Type Non- Compartmentalize/Cubical
  • Rated operated voltage 230VAC
  • Degree of Protection Up to IP66
  • Ambient temp Design Ambient temp. standard 40°C Operated 45°C & 50°C
  • Inspection and Testing Routine Test Control/Interlock Test Continuity Test Mechanical endurance Test
  • Fabrication or Standard make Enclosure MS CRCA sheet steel or SS304 Structure, door, cover: 1.6 mm thick Gland plate: 3mm thi
  • Component selection Selection basis on their rating and application,

Aiming to satisfy our clients optimally, we provide them with a quality approved array of PLC Panels. The offered panels are designed by our vendors’ skilled professionals, using optimum quality raw materials and latest technology in accordance with the international standards. To wire the control panels electronically is the primary function of PLC control panel. PLC panel will reduce the usage of number of relays. Space required for PLC is less when compared to relays hence there will be no space constraint.

Furthermore, offered products are made available in different sizes and various technical specifications to fulfill the various requirements of our clients.

View Complete Details

Feeder Pillar Panel

  • Application Power Distribution Power distribution with isolation Power distribution with selected
  • Construction Type Compartmentalize
  • Max. rated Current Up 800A Up to 65kA
  • Rated operated voltage 440V
  • Degree of Protection IP65
  • Fabrication CRCA sheet steel Structure, door, cover: 1.6 mm thick Gland plate: 3mm thick
  • Inspection and Testing Megger Test Routine test Mechanical endurance Test HV Test
  • Ambient temp Design Ambient temp. standard 40°C Operated 45°C & 50°C

Feeder pillars are the breaker panels which is the very first set of switching/protection device at the output/secondary side of the transformer and panel board is a set of switching/protection devices used for distribution of power supply.

Feeder pillar is an effective electrical enclosure to provide electrical services for low voltage electrical distribution applications. It is designed as compact and robust for vandalism protection. The metal enclosure is made of sheet steel of minimum 1.6mm thickness, mounted on a steel base frame of minimum 3mm thickness. Enclosure is suitable for outdoor application.

Feeder pillars are the breaker panels which is the very first set of switching/protection device at the output/secondary side of the transformer and panel board is a set of switching/protection devices used for distribution of power supply.

Feeder pillar is an effective electrical enclosure to provide electrical services for low voltage electrical distribution applications. It is designed as compact and robust for vandalism protection. The metal enclosure is made of sheet steel of minimum 1.6mm thickness, mounted on a steel base frame of minimum 3mm thickness. Enclosure is suitable for outdoor application.

View Complete Details

Marshaling Panel

  • Features Minimum Maintenance, Corrosion resistant
  • Phase Double Phase, Three Phase
  • Power 1-3kw
  • Material Metal
  • Voltage 220V
  • Frequency Range 50/60Hz

These can either be outdoor or indoor applications depending on the customer’s requirements. Marshalling kiosks are used to provide convenient connection points for the various control, protection and instrumentation wires which go to, and come from, all the different substation plants. This includes power, distribution and instrument transformers, switchgear and SCADA equipment.

Marshalling kiosks are usually custom designed for each application, ensuring the correct amount of equipment is included for both the currently envisaged requirement and for future expansion. They can be provided with front and rear access or front only access where substation space is limited.

View Complete Details

HT Panel

  • Application Transformer protection
  • Construction Type Indoor Outdoor Drawout type Non-Drawout type
  • Max. rated Current up to 1250A up to 65kA
  • Rated operated voltage 11KV to 66KV
  • Degree of Protection IP-65
  • Ambient temp Design Ambient temp. standard 40°C Operated 45°C & 50°C
  • Fabrication CRCA sheet steel structure, door, cover: 2 mm thick gland plate: 3mm thick

Definition – HT panel is a metal enclosure fitted with HT Circuit Breakers, relays &metering that is used to receive 11KV/33KV supply (from one or more source) & distribute the power through its outgoing feeders. Outgoing feeder may be one or more it depends on the load of the building.

 

HT panel is installedin substations of Commercial complexes, residential colonies, factories, schools, hospitals etc. to receive & distribute HT supply.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

Manufacturer of Electrical Panels & Distribution Box from Vadodara, Gujarat by AJ Technology
Post Buy Requirement
AJ Technology
gstGST : 24AMQPJ6923M1ZI Verified Add Review

Our Product / Services

  1. Electric Control Panels

    2 Products available
  2. Distribution Point Box

    1 Products available
  3. Repair & Maintenance Services

    1 Services available
  4. Instrumentation & Control Equipment

    1 Products available
  5. Breaker Panels

    1 Products available
  6. Switchgear Panels

    1 Products available
  7. Control Panels

    1 Products available
  8. Junction Box

    1 Products available

Electrical Panels & Distribution Box

We are leaders in the market for providing best range of Drive Panel, Plc Panel, Feeder Pillar Panel, Marshaling Panel and Ht Panel

Drive Panel

  • Type Manual VFD Panel Auto VFD Panel
  • Application Modulated type load Process plant Treatment plant Motor-driven machinery
  • Construction Type Compartmentalize Non- Compartmentalize/Cubical
  • Max. rated of VFD 400KW
  • Rated operated voltage 440V
  • Degree of Protection Up to IP54
  • Ambient temp Design Ambient temp. standard 40°C Operated 45°C & 50°C
  • Inspection and Testing Routine Test Control/Interlock Test Continuity Test Mechanical endurance Test
  • Fabrication Ms Crca Sheet Steel or Ss304 Structure, Door, Cover: 1.6 Mm Thick Gland Plate: 3mm Thick
  • Component selection Drive selection basis on their rating and application, input choke and output choke selection basis
  • Feature Manufacturers across the globe capitalize on AC variable frequency drive technology to save money

When a VFD starts a motor, it initially applies a low frequency and voltage to the motor. The starting frequency is typically 2 Hz or less. Starting at such a low frequency avoids the high inrush current that occurs when a motor is started by simply applying the utility (mains) voltage by turning on a switch. When VFD starts, the applied frequency and voltage are increased at a controlled rate or ramped up to accelerate the load without drawing excessive current.

This starting method typically allows a motor to develop 150% of its rated torque while drawing only 50% of its rated current. When a motor is simply switched on at full voltage, it initially draws at least 300% of its rated current while producing less than 50% of its rated torque. As the load accelerates, the available torque usually drops a little and then rises to a peak while the current remains very high until the motor approaches full speed. A VFD can be adjusted to produce a steady 150% starting torque from standstill right up to full speed while drawing only 50% current.

Additional Information:

Payment Terms : T/T

View Complete Details

Plc Panel

  • Application process plant Machinery Treatment plant
  • Construction Type Non- Compartmentalize/Cubical
  • Rated operated voltage 230VAC
  • Degree of Protection Up to IP66
  • Ambient temp Design Ambient temp. standard 40°C Operated 45°C & 50°C
  • Inspection and Testing Routine Test Control/Interlock Test Continuity Test Mechanical endurance Test
  • Fabrication or Standard make Enclosure MS CRCA sheet steel or SS304 Structure, door, cover: 1.6 mm thick Gland plate: 3mm thi
  • Component selection Selection basis on their rating and application,

Aiming to satisfy our clients optimally, we provide them with a quality approved array of PLC Panels. The offered panels are designed by our vendors’ skilled professionals, using optimum quality raw materials and latest technology in accordance with the international standards. To wire the control panels electronically is the primary function of PLC control panel. PLC panel will reduce the usage of number of relays. Space required for PLC is less when compared to relays hence there will be no space constraint.

Furthermore, offered products are made available in different sizes and various technical specifications to fulfill the various requirements of our clients.

View Complete Details

Feeder Pillar Panel

  • Application Power Distribution Power distribution with isolation Power distribution with selected
  • Construction Type Compartmentalize
  • Max. rated Current Up 800A Up to 65kA
  • Rated operated voltage 440V
  • Degree of Protection IP65
  • Fabrication CRCA sheet steel Structure, door, cover: 1.6 mm thick Gland plate: 3mm thick
  • Inspection and Testing Megger Test Routine test Mechanical endurance Test HV Test
  • Ambient temp Design Ambient temp. standard 40°C Operated 45°C & 50°C

Feeder pillars are the breaker panels which is the very first set of switching/protection device at the output/secondary side of the transformer and panel board is a set of switching/protection devices used for distribution of power supply.

Feeder pillar is an effective electrical enclosure to provide electrical services for low voltage electrical distribution applications. It is designed as compact and robust for vandalism protection. The metal enclosure is made of sheet steel of minimum 1.6mm thickness, mounted on a steel base frame of minimum 3mm thickness. Enclosure is suitable for outdoor application.

Feeder pillars are the breaker panels which is the very first set of switching/protection device at the output/secondary side of the transformer and panel board is a set of switching/protection devices used for distribution of power supply.

Feeder pillar is an effective electrical enclosure to provide electrical services for low voltage electrical distribution applications. It is designed as compact and robust for vandalism protection. The metal enclosure is made of sheet steel of minimum 1.6mm thickness, mounted on a steel base frame of minimum 3mm thickness. Enclosure is suitable for outdoor application.

View Complete Details

Marshaling Panel

  • Features Minimum Maintenance, Corrosion resistant
  • Phase Double Phase, Three Phase
  • Power 1-3kw
  • Material Metal
  • Voltage 220V
  • Frequency Range 50/60Hz

These can either be outdoor or indoor applications depending on the customer’s requirements. Marshalling kiosks are used to provide convenient connection points for the various control, protection and instrumentation wires which go to, and come from, all the different substation plants. This includes power, distribution and instrument transformers, switchgear and SCADA equipment.

Marshalling kiosks are usually custom designed for each application, ensuring the correct amount of equipment is included for both the currently envisaged requirement and for future expansion. They can be provided with front and rear access or front only access where substation space is limited.

View Complete Details

HT Panel

  • Application Transformer protection
  • Construction Type Indoor Outdoor Drawout type Non-Drawout type
  • Max. rated Current up to 1250A up to 65kA
  • Rated operated voltage 11KV to 66KV
  • Degree of Protection IP-65
  • Ambient temp Design Ambient temp. standard 40°C Operated 45°C & 50°C
  • Fabrication CRCA sheet steel structure, door, cover: 2 mm thick gland plate: 3mm thick

Definition – HT panel is a metal enclosure fitted with HT Circuit Breakers, relays &metering that is used to receive 11KV/33KV supply (from one or more source) & distribute the power through its outgoing feeders. Outgoing feeder may be one or more it depends on the load of the building.

 

HT panel is installedin substations of Commercial complexes, residential colonies, factories, schools, hospitals etc. to receive & distribute HT supply.