Fuse Switch Disconnector

  • Technical Details Specs
  •    
  •     CATALOGUE REFERENCE
  • ADPM - 1/160A  
  •   BODY MATERIAL Polyamide
  •     RATED OPERATIONAL CURRENT In
  • 160 Amps  
  •   RATED OPERATIONAL VOLTAGE u 660 Volts, 50 Hz e
  •     RATED INSULATION VOLTAGE Ui
  • 1000 Volts  
  •   RATED SHORT TIME CURRENT Icw 10 kA rms for 0.5 s with 17 kA
  •     CABLE SIZE
  • upto 95 sq. mm.  
  •   FUSE LINKS NH Type Size 0
  •     DIMENSIONS
  • 235 X 160 X 70 mm (Approx.) Single Pole  
  •   WEIGHT (S.P. Unit) 720 grams Approx. - Not Binding (Without Fuses & Clamp)

The basic function of 160A Pole Mounted Fuse Switch Disconnecter is to protect and disconnect a network during
faults and is specially designed for on-load switching. The switch offers a reliable medium for disconnection and
protection of fully insulated open wire network. The fuse switch is versatile and ideally suited for mounting
directly to poles, transformers and cross arms.
Features
* Designed for full load switching with Fuse links or disconnecting blades upto a rated current.
* Integral mounting facility and unique modular design allowing one, two, three or more switches to be installed
together to meet SP, TP or TPN system requirements.
* Fully insulated made from corrosion proof, impact resistant, weather and UV resilient glass fibre reinforced
polyamide compound with high glass content suitable for consistent performance under adverse climatic conditions.
* The upper housing of the switch is hinged to the lower body and can be withdrawn by the insulated operating rod
thereby enables, changing of fuses from ground level.
* Flexibility of linking a series of flaps for simultaneous operation.
* The contacts, made up of ETP grade copper - duly plated are rigidly mounted in the housing independent of the
terminal bolts. Single incoming
and Double outgoing termination is provided in standard version.
* Electrical & Mechanical fuse indicators are provided to show status of blown fuse.
* Mounting clamp & Coach screw provided along with for easy mounting.
Miniature version
A miniature version is also available with all listed features and neon indicator to indicate status of blown fuse.
The design is relatively smaller, light
weight but robust to meet adverse climatic conditions as per pollution level 3 & technical characteristics of IEC-
60947 - 1 & 3.
A choice of termination is available to meet any requirement.
The basic function of 160A Pole Mounted Fuse Switch
Terminations Available
Based on the requirement of the customer, we can supply Fuse switch disconnector with either Bolted, Pillar or V
Groove Termination.
Type Testing
The fuse switch has been extensively type tested at CPRI -a laboratory of International repute as per IEC 60947
part 1, & 3:

View Complete Details

Gang Operated Switch

The Surge Arrestors are an indispensable protection devise which needs to protect a transformer against natural lightning & switching surges in a high voltage system. They are designed for satisfactory performance in critical atmospheric conditions of highlow temperatures & humidity. Asiatic offers the latest Gap less Metal oxide technology which is far superior than conventional systems being used previously in terms of vast improvement in VA curves & increased through current capability at over voltages.
View Complete Details

Strip Fuse Ways

LV HRC fuse bases can be combined to form distribution systems having desired number of electrical circuits.
Due to their compact design these are particularly suitable for distribution application in Service Cabinets, Feeder Pillars and Distribution Boards.
The body of the fuse base is made of glass fibre reinforced polyster on which the spring loaded silver/tin plated fuse contacts are mounted. Fuse contacts are covered with shroud of insulating material for added safety against accidental contact.
The fuse bases are bolted directly to the bus bars. The terminals of the fuse bases are tin of plated copper.
The LV HRC fuse bases comply generally with DIN 43623:
Size 1-3 Form B Provided with vertical droppers for cable connection at bottom The fuse bases of Sizes 1-3 are suitable for a spacing
between bus bar centers of 185 mm and depth of 153 mm.

 Type GDVF-3/250A GDVF-3/400A GDVF-3/630A              
  RATED Operating Voltage 500 V, 50 Hz 500 V, 50 Hz 500 V, 50 Hz              
  Rated Thermal Current 250 A, Size 1 400 A, Size 2 630 A, Size 3              
  Rating Insulation Voltage 660 V 660 V 660 V              
  HRC Fuse Links DIN 43620 DIN 43620 DIN 43620              
  Short time withstand Capacity (Dynamic Peak) 10kA 18.62 kA 22.66 kA              
  Weight Without Fuse Links 2.650 KG 3.405 KG 4.105 KG              
  Short Circuit Capacity with HRC Fuse Links 50 kA (Prospective) 50 kA (Prospective) 50 kA (Prospective)
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us