Our Products
Safety System & Equipments
1 Products availableTrolleys
1 Products availableOffice And Commercial Furniture
1 Products availableModular Office Workstation
1 Products availableSteel & Steel Products
1 Products availableWe offer a complete product range of Vertical Laminar Flow, Weighing Booth Extractor, Unidirection Air Flow Benches, Mobile Laminar Air Flow Unit and Air Pack Technical System
Vertical Laminar Flow Unitis designed specifically for product protection. The Cabinet is a clean bench which provides ultra clean sterile HEPA filtered class 100 air in an isolated area for operations requiring a particulate-free environment where the highly sensitive process activities are carried-out.
The Vertical laminar air Flow Unitdraws air in through the top of the unit through a pre-filter, through a plenum and vertically down over the work-surface and past the lap of the operator. It has the advantage of not pushing air into the face of the operator as in ahorizontal laminar air flow cabinet.The laminar air flow cabinets are used for work with low-risk substances and materials, when protection of working material from environment is required or work with item requires a sterile working zone. Cabinets are used for equipment of local workplaces in medical, pharmaceutical and other institutes with high requirements for air cleanliness in the working zone.
Vertical Laminar Air Flow Unitis with a variety of standard dimensions also our unit can be custom engineered to any size. Laminar air flow available in powder coatedMild Steel, SS 304 / 316 / 316Lor a combination of both.
Technical Specification :
Supply filter : | Imported Minipleat HEPA filter with hot melt technology, which conforms to EU-14 Grade at supply position with an efficiency rating better than 99.999% down to 0.3 |
Pre-filter : | Pre-filter are made from non-woven synthetic with HDPE mesh; conforms to EU 6 grade, with an efficiency rating better than 95% down to 5. |
MotorAlower Assembly : | Motor blower designed of statically and dynamically balanced for supply of sufficient capacity and static pressure to take care of airflow requirement for entire life of HEPA. |
Differential Pressure Gauge : | Dwyer make magnehelic Gauge (0 -25 mm: 1 No.) to monitor pressure drop across HEPA. s |
Lighting : | Fluorescent light with milky white diffuser (250 Lux) at work surface |
ON/OFF Switches : | SS ON/OFF switches for motor & lights |
Switch Socket : | 6/15 amp single-phase switch socket use for external equipment |
Work Table : | SS work table with due reinforcement |
Side Panel : | Glass side panel screens for maximum visibility |
DOP Port : | DOP test port at upstream of HEPA filter to personnel for carrying out the HEPA filter integrity test (with PAO solution). |
Switch Socket : | 6/15 amp single-phase switch socket use for external equipment |
DOP Port : | DOP test port at upstream of HEPA filter to personnel for carrying out the HEPA filter integrity test (with PAO solution). |
Electrical Supply : | 230V AC 1- 50HZ / 415V AC 3- 50HZ |
Noise Level : | Less than 67 dB on Scale A when ambient is not greater than 55 dB on scale A |
Vibration Level : | Minimum |
Optional Accessories :
Standard Model Available :
MODEL NO. | HEPA FILTER AREA (MM) | AIRFLOW VELOCITY (DOWN FLOW) |
AIR CLEANLINESS |
---|---|---|---|
CSVLAF-36-24 | 915 x 610 | ||
CSVLAF-48-24 | 1220 x 610 | 0.45±0.05mps/ | ISO Class 5 (ISO 14644-1:1999 (E)) / |
SMVLAF-36-24-30 | 915 x 610 | 90(fpm) | Class 100 (U.S. FED STD 209 E) |
SMVLAF-48-30-30 | 1220 x 762 |
weighing booth extractor Unitiswith a variety of standard dimensions also our cabinet can be custom engineered to any size. Weighing Booth Extractor available in powder coatedMild Steel, SS 304 / 316 / 316Lor a combination of both.
MODEL NO. | WORKING AREA (MM) | AIRFLOW VELOCITY (DOWN FLOW) |
AIR CLEANLINESS | AIR FLOW |
---|---|---|---|---|
WBE-48-36 | 1260 X 955 X 2170 | 0.45±0.05mps/ | ISO Class 5 (ISO 14644-1:1999 (E)) / | Vertical – |
WBE-48-48 | 1275 X 1260 X 2170 | 90(fpm) | Class 100 (U.S. FED STD 209 E) | Recirculatory |
Technical Specification :
Exhaust HEPA filter : |
Imported Minipleat HEPA filter with hot melt technology, which conforms to EU-14 Grade at exhaust position with an efficiency rating better than 99.999% for 0.3µ. |
Pre-filter : | Prefilter are made from non-woven synthetic with HDPE mesh; conforms to EU 6 Grade, with an efficiency rating better than 95% down to 5µ. |
Motor Alower Assembly : |
Motor blower designed of statically and dynamically balanced for supply of sufficient capacity and static pressure to take care of airflow requirement for entire life of HEPA. |
Differential Pressure Gauge : | Dwyer Make Magnehelic Gauge (0 -25 mm: 1 No.) to monitor pressure drop across HEPA filter. |
Lighting : | Fluorescent light (250 Lux) at work surface |
ON/OFF Switches : | SS ON/OFF switches for motor & lights |
Switch Socket : | 6/15 amp single-phase switch socket use for external equipment |
Control System : | Electrical control panel mounted on the side panel of the unit. |
Door : | SS 304 double walled door construction with flush glass view panels with door closer, SS handles and SS hinges |
Door release (Push type) : |
Door release provides from the front of the unit. |
DOP Port : | DOP test port at upstream of HEPA filter to personnel for carrying out the HEPA filter integrity test. |
Exhaust Duct : | SS 304 1 ft long elbow duct for exhaust |
Side Panel : | SS 304 Double Walled Side Panels. |
Electrical Supply : | 230V AC 1Ø 50Hz / 415 V AC 3Ø 50 Hz |
Noise Level : | Less than 67 dB on scale ‘A’ when ambient is not greater than 55 dB on scale ‘A’ |
Vibration Level : | Minimum |
Optional Accessories :
It prevents contamination from operator and environment to work area. The laminarity of the flow prevents cross contamination between the items handled in the working space. These units are suitable for the handling of non-hazardous products, sensible to dust and/or to contamination wherever operator protection is not required.
Unidirectional Air Flow Unitswith a variety of standard dimensions also our cabinet can be custom engineered to any size. Unidirectional air flow are available in powderTechnical Specification :
Supply filter : | Imported Minipleat HEPA filter with hot melt technology, which conforms to EU-14 Grade at supply position with an efficiency rating better than 99.999% down to 0.3. |
Pre-filter : | Fresh Air filter are made from non-woven synthetic with HDPE mesh; conforms to EU 6 grade, with an efficiency rating better than 95% down to 5. |
MotorAlower Assembly : | Motor blower designed of statically and dynamically balanced for supply of sufficient capacity and static pressure to take care of airflow requirement for entire life of HEPA. |
Differential Pressure Gauge : | Dwyer Make Magnehelic Gauge (0 -25 mm: 1 No.) to monitor pressure drop across HEPA. |
Lighting : | Fluorescent light (250 Lux) at work surface |
ON/OFF Switches : | SS ON/OFF switches for motor & lights |
Switch Socket : | 6/15 amp single-phase switch socket use for external equipment |
Control Panel : | Electrical control panel mounted on the side panel of the unit. |
DOP Port : | DOP test port at upstream of HEPA filter to personnel for carrying out the HEPA filter integrity test. |
Side Panel : | Double skin side panels with glass view panel |
Electrical Supply: : | 230V AC 1 50Hz / 415V AC 3 Hz |
Noise Level : | Less than 67 dB on scale A when ambient is not greater than 55 dB on scale A |
Vibration Level : | Minimum |
Optional Accessories :
coatedMild Steel, SS 304 / 316 / 316Lor a combination of both.
MODEL NO. | HEPA FILTER AREA (MM) | AIRFLOW VELOCITY (DOWN FLOW) |
AIR CLEANLINESS | AIR FLOW |
---|---|---|---|---|
UDAF-48-36 | 1220 X 915 | 0.45±0.05mps / | ISO Class 5 (ISO 14644-1:1999 (E)) / | Vertical |
UDAF-48-48 | 1220 X 1220 | 90(fpm) | Class 100 (U.S.FED STD 209 E) | -Recirculatory |
Biological safety cabinetis designed to provide both a clean work environment and protection to operators who work with biological hazards. It has vertical laminar airflow to create a barrier to airborne particles and microorganisms. High Efficiency Particulate Air (HEPA) filters are used to provide clean air in the work area as well as to the environment through exhaust with the HEPA filter. The air in the cabinet is re-circulated over the work area through the HEPA filter, It is a contaminant-free environmental Protection.
Biological Safety Cabinetrange includes a variety of containment products to suit laboratory applications within the academic, pharmaceutical, biotech, healthcare, R&D and industrial sectors. Our advanced biological safety cabinets have been designed with safety and efficiency in mind. User-friendly features and advanced control systems make these cabinets both versatile and reliable. The biosafety cabinets are classified into three categoriesClass I , Class IIorClass IIIprovides a range of solutions for the containment of category.
Class II :The Class II vertical laminar-flow biological cabinet is an open-front, ventilated cabinet. This cabinet provides a HEPA-filtered re circulated mass airflow within the workspace.The exhaust air from the cabinet is also filtered by HEPA filter. Thus, Class II bio safety cabinet provides protection to product as well as to human beings and environment. While HEPA filters are effective for trapping particulates and infectious agents, it is suitable for the containment of bio hazardous material thereby providing sterile environment for cell culture. Class II cabinet is most versatile and economical model.
Technical Specification :
Supply filter : | Imported Minipleat HEPA filter with hot melt technology, which conforms to EU-14 Grade at supply position with an efficiency rating better than 99.999% down to 0.3. |
ExhaustHEPA filter : | Imported Minipleat HEPA filter with hot melt technology, which conforms to EU-14 Grade at exhaust position with an efficiency rating better than 99.999% for 0.3. |
Pre-filter : | Fresh Air Pre-filter are made from non-woven synthetic with HDPE mesh; conforms to EU 6 grade, with an efficiency rating better than 95% down to 5. |
MotorBlower Assembly : | Motor blower designed of statically and dynamically balanced for supply of sufficient capacity and static pressure to take care of airflow requirement for entire life of HEPA. |
Differential Pressure Gauge : | Dwyer Make Magnehelic Gauge (0 -25 mm: 2 Nos.) to monitor pressure drop across HEPA filter & work area with respect to ambient. |
Lighting : | Fluorescent light (250 Lux) at work surface |
ON/OFF Switches : | SS ON/OFF switches for motor & lights |
SS 304 work table : | SS 304 work table with perforations at front & back which can be removed occasionally for cleaning purpose |
front door : | 1-piece fully openable sliding toughened glass with counterweight arrangement |
DoorOpening Alarm : | Alarm triggers in case front door is raised more than 8 (i.e. safe clear door opening during operation) |
Exhaust Duct : | SS 304 stands with leveling lugs |
Side panel : | Double walled flushed glass side panels |
Electrical Supply : | 230V AC 1- 50HZ / 415V AC 3- 50HZ |
Noise Level : | Less than 67 dB on scale A when ambient is not greater than 55 dB on Scale A |
Vibration Level : | Minimum |
Optional Accessories :
Sodium vaporlamps
MODEL NO. | WORKING AREA (MM) | AIRFLOW VELOCITY (DOWN FLOW) |
AIR CLEANLINESS | AIR FLOW |
---|---|---|---|---|
BSC-36-24-24 | 915 X 610 X 610 | 0.45±0.05mps | ISO Class 5 (ISO 14644-1:1999 (E)) / | Vertical – |
BSC-48-24-24 | 1220 X 610 X 610 | 90(fpm) | Class 100 (U.S.FED STD 209 E) | Recirculatory |
Mobile Trolleyis designed for transporting sterile products under ISO Class 5 (Class 100) particle free work area for storing sterile products to meet storage needs while making a positive contribution to maintaining the cleanliness of your controlled cleanroom environment. The work area is continuously supplied with positive pressure HEPA filtered recirculated vertical / horizontal air flow. Our range ofmobile trolley cabinetis available in various specifications as per the clients requirements.Mobile Trolleyis with a variety of standard dimensions also our Mobile Trolley can be custom engineered to any size. Mobile Trolley is available in powder coated Mild Steel, SS 304 / 316 / 316L or a combination of both.
Technical Specification :
Supply filter : | Imported Minipleat HEPA filter with hot melt technology, which conforms to EU-14 Grade at supply position with an efficiency rating better than 99.999% down to 0.3. |
Return Air Pre-filter : | Return Air Pre-filter are made from non-woven synthetic with HDPE mesh; conforms to EU 6 grade, with an efficiency rating better than 95% down to 5. |
Fresh Air Filter : | Fresh Air Pre-filter are made from non-woven synthetic with HDPE mesh; conforms to EU 4 Grade, with an efficiency rating better than 90% down to 10. |
Motor Alower Assembly : | Motor blower designed of statically and dynamically balanced for supply of sufficient capacity and static pressure to take care of airflow requirement for entire life of HEPA. |
Differential Pressure Gauge : | Dwyer Make Magnehelic Gauge (0 -25 mm: 1 No.) to monitor pressure drop across HEPA. |
Door : | SS 304 double walled door construction with flush glass view panels with SS handles and SS hinges. |
Interlocking : | Electro-Magnetic interlocking arrangement to put-off UV Light if either side door opens. |
Shelves : | SS 304 hanging arrangement (or) removable type shelves |
Temperature Control : | Heater with thermostat for control of temperature in cabinet |
Battery back-up : | Battery back-up with inverter for 30 mins |
Castrol wheel : | PU coated lockable castor wheels |
ON/OFF Switches : | SS ON/OFF switches for motor & lights |
Switch Socket : | 6/15 amp single-phase switch socket use for external equipment |
DOP Port : | DOP test port at upstream of HEPA filter to personnel for carrying out the HEPA filter integrity test. |
Handle : | SS 304 Handle for mobility |
Electrical Supply : | 230V AC 1- 50HZ / 415V AC 3- 50HZ |
Noise Level : | Less than 67 dB on scale A when ambient is not greater than 55 dB on scale A |
Vibration Level : | Minimum |
Optional Accessories :
Standard Model Available :
MODEL NO. | WORK AREA (MM) | AIRFLOW VELOCITY (DOWN FLOW) | AIR CLEANLINESS | AIR FLOW |
---|---|---|---|---|
MT-24-24-24 | 610 X 610 X 610 | 0.45±0.05mps/ | ISO Class 5 (ISO 14644-1:1999 (E)) / | Horizontal – Recirculatory |
MT-24-24-36 | 610 X 610 X 915 | 90(fpm) | Class 100 (U.S. FED STD 209 E) |
Garment Storage Cabinetis designed to provide ISO Class 5 (Class 100) particle free work area for storing sterile packed garments to meet garment storage needs while making a positive contribution to maintaining the cleanliness of your controlled cleanroom environment.
Cleanroom garments can accumulate particulate contamination during storage and between laundry washes, which in turn may lead to lower product yields and increased product quality issues. The work area is continuously supplied with positive pressure HEPA filtered re-circulated vertical / horizontal air flow.
These are widely used for storage of clean apparel for clean rooms as these are equipped with HEPA filter and U.V. germicidal tube. Therefore, these are safe and ensure that the garments completely free from bacterial contamination.
Our range ofGarment Storage Cabinetis available in various specifications as per the clients requirements. Garment Storage Cabinet is with a variety of standard dimensions also our Garment Cabinet can be custom engineered to any size. Garment Storage Cabinet available in powder coatedMild Steel, SS 304 / 316 / 316Lor a combination of both.
:Technical Specification :
Supply filter : | Imported Minipleat HEPA filter with hot melt technology, which conforms to EU-14 Grade at supply position with an efficiency rating better than 99.999% down to 0.3. |
ReturnAir Pre-filter : | Return Air Pre-filter are made from non-woven synthetic with HDPE mesh; conforms to EU 6 grade, with an efficiency rating better than 95% down to 5. |
FreshAir Filter : | Fresh Air Filter Made from non-woven synthetic with HDPE mesh; conforms to EU 4 Grade, with an efficiency rating better than 90% down to 10. |
MotorAlower Assembly : | Motor blower designed of statically and dynamically balanced for supply of sufficient capacity and static pressure to take care of airflow requirement for entire life of HEPA. |
Differential Pressure Gauge : | Dwyer Make Magnehelic Gauge (0 -25 mm: 1 No.) to monitor pressure drop across HEPA. |
Door : | SS 304 double walled door construction with flush glass view panels with SS handles and SS hinges. |
Interlocking : | Electro-Magnetic interlocking arrangement to put-off UV Light if either side door opens. |
Shelves : | SS 304 hanging arrangement (or) removable type shelves |
Temperature Control : | Heater with thermostat for control of temperature |
ON/OFF Switches : | SS ON/OFF switches for motor & lights |
Switch Socket : | 6/15 amp single-phase switch socket use for external equipment |
DOP Port : | DOP test port at upstream of HEPA filter to personnel for carrying out the HEPA filter integrity test. |
Electrical Supply : | 230V AC 1- 50HZ / 415V AC 3- 50HZ |
Noise Level : | Less than 67 dB on scale A when ambient is not greater than 55 dB on scale A |
Vibration Level : | Minimum |
Optional Accessories :
Standard Model Available :
MODEL NO. | WORK AREA (MM) | AIRFLOW VELOCITY (DOWN FLOW) |
AIR CLEANLINESS | AIR FLOW |
---|---|---|---|---|
GSC-24-24-24 | 610 X 610 X 610 | 0.45±0.05mps/ | ISO Class 5 (ISO 14644-1:1999 (E)) / | Vertical / Horizontal |
GSC-24-24-36 | 610 X 610 X 915 | 90(fpm) | Class 100 (U.S. FED STD 209 E) | – Recirculatory |
GSC-36-24-24 | 915 X 610 X 610 | (Based on application) |
Mobile Laminar Air Flow Unitis designed for transporting sterile products under ISO Class 5 (Class 100) particle free work area to ensure product integrity. The work area is continuously supplied with positive pressure HEPA filtered recirculated horizontal air flow.
Mobile Laminar Air Flow Unitis with a variety of standard dimensions also our cabinet can be custom engineered to any size. Mobile Laminar air flow available in powder coatedMild Steel, SS 304 / 316 / 316Lor a combination of both.echnical Specification :
Supply filter : | Imported Minipleat HEPA filter with hot melt technology, which conforms to EU-14 Grade at supply position with an efficiency rating better than 99.999% down to 0.3. |
Pre-filter : | Pre-filter are made from non-woven synthetic with HDPE mesh; conforms to EU 6 grade, with an efficiency rating better than 95% down to 5. |
MotorBlower Assembly : | Motor blower designed of statically and dynamically balanced for supply of sufficient capacity and static pressure to take care of airflow requirement for entire life of HEPA. |
Differential Pressure Gauge : | Dwyer Make Magnehelic Gauge (0 -25 mm: 1 No.) to monitor pressure drop across HEPA. |
Lighting : | Fluorescent light with milky white diffuser (250 Lux) at work surface |
ON/OFF Switches : | SS ON/OFF switches for motor & lights |
Switch Socket : | 6/15 amp single-phase switch socket use for external equipment |
Control Panel : | Electrical control panel mounted in the unit. |
DOP Port : | DOP test port at upstream of HEPA filter to personnel for carrying out the HEPA filter integrity test with (PAO) solution. |
Battery back-up : | Battery back-up with inverter for 30 mins |
Handel : | SS 304 handle for mobility |
Castrol wheel : | PU coated lockable castor wheels |
Electrical Supply : | 230V AC 1- 50HZ / 415V AC 3- 50HZ |
Noise Level : | Less than 67 dB on scale A when ambient is not greater than 55 dB on scale A |
Vibration Level : | Minimum |
Optional Accessories :
Standard Model Available :
MODEL NO. | WORKING AREA (MM) | AIRFLOW VELOCITY (DOWN FLOW) |
AIR CLEANLINESS | AIR FLOW |
---|---|---|---|---|
MLAF-36-30-30 | 915 x 760 x 760 | |||
MLAF-48-30-30 | 1220 x 760 x 760 | 0.45±0.05mps/ | ISO Class 5 (ISO 14644-1:1999 (E)) / | |
MLAF-60-30-30 | 1525 x 760 x 760 | 90(fpm) | Class 100 (U.S. FED STD 209 E) |
Vertical |
MLAF-72-30-30 | 1830 x 760 x 760 |
The Horizontal Laminar Flow workstationis designed specifically for highest product protection by providing ISO Class 5 particle free work area for handling critical process. The main HEPA filter is situated immediately behind the working area; clean air is then blown across the work surface towards the operator. The work area is continuously supplied with positive pressure HEPA filtered horizontal air flow. It prevents contamination from operator and environment to work area. The laminarity of the flow prevents cross contamination between the items handled in the working space.
These units are suitable for the handling of non-hazardous products, sensible to dust and/or to contamination wherever operator protection is not required.
Horizontal Laminar Air Flow Unitis with a variety of standard dimensions also our cabinet can be custom engineered to any size. Horizontal Laminar air flow are available in powder coatedMild Steel, SS 304 / 316 / 316Lor a combination of both.
Technical Specification :
Supply filter : | Imported Minipleat HEPA filter with hot melt technology, which conforms to EU-14 Grade at supply position with an efficiency rating better than 99.999% down to 0.3. |
Pre-filter : | Made from non-woven synthetic with HDPE mesh; conforms to EU 6 grade, with an efficiency rating better than 95% down to 5. |
MotorAlower Assembly : | Motor blower designed of statically and dynamically balanced for supply of sufficient capacity and static pressure to take care of airflow requirement for entire life of HEPA. |
Differential Pressure Gauge : | Dwyer Make Magnehelic Gauge (0 -25 mm: 1 No.) to monitor pressure drop across HEPA. |
Lighting : | Fluorescent light with milky white diffuser (250 Lux) at work surface |
ON/OFF Switches : | SS ON/OFF switches for motor & lights |
Switch Socket : | 6/15 amp single-phase switch socket use for external equipment |
Work Table : | SS work table with due reinforcement |
Side Panel : | Glass side panel screens for maximum visibility |
DOP Port : | DOP test port at upstream of HEPA filter to personnel for carrying out the HEPA filter integrity test. |
Electrical Supply : | 230V AC 1- 50HZ / 415V AC 3- 50HZ |
Noise Level : | Less than 67 dB on scale A when ambient is not greater than 55 dB on scale A |
Vibration Level : | Minimum |
Optional Accessories :
Standard Model Available :
MODEL NO. | WORK AREA (MM) | AIRFLOW VELOCITY (DOWN FLOW) |
AIR CLEANLINESS | AIR FLOW |
---|---|---|---|---|
HLAF-36-24-24 | 915 x 610 x 610 | |||
HLAF-48-24-24 | 1220 x 610 x 610 | 0.45±0.05mps/ | ISO Class 5 (ISO 14644-1:1999 (E)) / | |
HLAF-48-24-30 | 1220 x 610 x 760 | 90(fpm) | Class 100 (U.S. FED STD 209 E) |
Horizontal |
We have manufacturing of all type (Standard and non standard) of ss furniture as per cGMP
Air Pack Technical SolutionsHVAC provides world class environmental control for high precision industries like pharmaceutical, Biotech, Healthcare, Food & Beverages, Research & Development labs, electronics and semi conductors, manufacturing industries and hospitality industry.
Some of the important components of the wide product range include: