Our Products
We offer the best product range of Sterilizing, Dry Heat Sterilizer, Vertical Autoclave Sterilizer, ETO Sterilizer and Surgical ETO Gas Sterilizer.
Salient Features
Salient Features
Process Operation
The Ampoules / Vials placed in trays are washed in non-sterile room and loaded on the trolley. The trolley is moved to the sterilizer on a transfer trolley. Temperature and Times are set on the Digital Controller. The Impeller mounted on the top circulates the hot air horizontally over the charge. The air is heated by elements mounted on the top. Fresh air enters the system through Hepa Filter Module. The system incorporates two doors, one opening into the sterile room and the other opening in the non-sterile room. Both the doors are pneumatically interlocked. The temperature profile during sterilization cycle is recorded on a circular chart recorder, validation of the system is provided by a six-point digital temperature scanner. After the time period required for sterilizing the batch has elapsed, the heating circuit shuts of the pneumatics damper (exhaust) opens and cooling operation commences.
Temperature | Up to 250°C |
Material of Construction | Interiors with 14 gauge S.S. 316 quality sheets. Exteriors with 16 gauge S.S. 304 Quality sheet. Frame work of Rolled steel sections 6, 5 & 3mm. the interior frame work of S.S 316 quality |
Trolley | Fabricated from AISI SS 316 Quality angles & flats with ‘U’-Grooved Stainless Steel wheels. |
Transfer trolley | Fabricated from S.S. 304 Quality Angles & flats with castor wheel for sterile & Non-sterile room. |
Doors | Two Doors, one opening into the sterile room and the other into the Non-sterile room. The doors are lined with silicon rubber for sealing. The door in the sterile room is claded with 16 gauge AISI SS 304 sheet. |
Interlocking | To maintain the barrier between the sterile and non-sterile room, both the doors are pneumatically interlocked. The pneumatic system consists of pneumatic Cylinders, solenoid valves and flow control valves. |
Insulation | 125mm (t) Mineral Wool. A grade mineral wool insulation to optimize heat effectiveness and stop heat loses. |
Air recirculation | A 2 H.P. 1440-RPM motor drives the impeller. Air enters the Chamber through perforations provided passes horizontally over the charge and is re-circulated. |
HEPA Filter Module | Air entering the system is passed through a HEPA Filter Module consisting of a pre-filter up to 5 microns, a blower & a HEPA Filter up to 0.3 microns. The filtered air is fed to the impeller for circulating in the system. |
Temperature Control & Timer | A combined Electronic Digital Controller & Timer is installed. ±2ºC., one probe centrally mounted. |
Scanner | A six point Digital Scanner is incorporated, with facility of Hold & Scan at all six points. |
Temperature Recorder | A, 1 point Circular Chart recorder is installed with chart Dia. 8” |
Cooling Coils | Crimped Finned Tubes with headers, S.S. 304 Quality to speed up cooling cycle. |
Panel Board | Consists of: Ammeters, Voltmeter, Voltmeter switch, HRC fuses & Circular chart Recorder |
Control panel | Motor Starter, Contactors, Rotary Switches, Indicating lights for heating & Cooling cycle and phase indicating lights. |
Exhaust damper | Controlled by solenoid valve and is opened during the initial heat-up, shuts off and re-opens during cooling cycle. |
Fan | Dynamically balanced fan provided for hot air circulation to achieve uniform temperature |
Finish | All stainless steel components buffed to matt finish. |
Durable Stainless steel Construction |
Low power consumption |
Model |
AHS-1 |
AHS-2 |
AHS-3 |
AHS-4 |
AHS-5 |
Internal Tank Capacity (Liters) |
78 Liters |
135 Liters |
152 Liters |
162 Liters |
240 Liters |
Design |
Rectangular & Cylindrical Type |
||||
Working Pressure |
Variable 5 to 30 PSI |
||||
Working Temperature |
121°C (up graded up to 135°C) |
||||
Internal Chamber |
Corrosion Resistant Stainless Steel |
||||
External Chamber |
Corrosion Resistant 304 Grade Stainless Steel, Painted |
||||
Door |
Single or Double Doors w/ automatic pressure locking |
||||
Insulation |
Glass wool Fiber |
||||
Sterilization Period |
20 to 25 Minutes |
||||
Steam Exhaust |
5 to 7 Minutes |
||||
Boiler |
With ISI marked water immersion type industrial heating elements, Pressure stat, |
||||
Safety Valve |
For excess pressure inside jacket and steam generator |
||||
Thermometer |
Dial Type, indicates sterilization temperature |
||||
Mechanical Time w/ Alarm |
Regulates sterilization time and activates buzzer when sterilization cycle completes |
||||
Vacuum drying |
Optional |
||||
Auto add water |
Optional |
||||
Door interlock |
Optional |
||||
Other Accessories |
Automatic Pressure control switch, water cut-off, Temperature indicator |
||||
Standard Accessories |
SS304 Sterilizing tray x 1pc |
||||
Caster Wheels |
Optional |
||||
Power Supply |
220 Volts / 440 Volts |
Model in Feet | Volumetric capacity in m3 | Working Pressure | Working Temperature | Vacuum Pump | Water Circulation Pump | Electric Heaters |
2x2x4 | 0.45 m³ | 1 to 1.5 kg/cm² | 55 to 60°C | 1 H.P. | 0.5 H.P. | 3 KW |
3x3x6 | 1.46 m³ | 1 to 1.5 kg/cm² | 55 to 60°C | 1.5 H.P. | 0.5 H.P. | 6 KW |
4x4x6 | 2.72 m³ | 1.0 to1.5 kg/cm² | 55 to 60°C | 1.5 H.P. | 0.5 H.P. | 6 KW |
4x4x8 | 3.60 m³ | 1.0 to1.5 kg/cm² | 55 to 60°C | 2 H.P. | 1 H.P. | 9 KW |
5x5x10 | 6.97 m³ | 1.0 to1.5 kg/cm² | 55 to 60°C | 3 H.P. | 1 H.P. | 12 KW |
5x5x15 | 11.25 m³ | 1.0 to1.5 kg/cm² | 55 to 60°C | 3 H.P. | 1 H.P. | 12 KW |
6x6x15 | 16.2 m³ | 1.0 to1.5 kg/cm² | 55 to 60°C | 5 H.P. | 1.5 H.P. | 18 KW |
6x6x20 | 19.44 m³ | 1.0 to1.5 kg/cm² | 55 to 60°C | 5 H.P. | 1.5 H.P. | 27 KW |
7x7x20 | 26.46 m³ | 1.0 to1.5 kg/cm² | 55 to 60°C | 7.5 H.P. | 2 H.P. | 36 KW |
7x7x30 | 44.1 m³ | 1.0 to1.5 kg/cm² | 55 to 60°C | 10 H.P. | 2 H.P. | 54 KW |
Adinath's Ethylene Oxide Gas Sterilizer has been specially designed for sterilization of products sensitive to high temperature and to humidity (Syringes, Defluxers, Catheters, Cartridges for Dialysis, Plastic articles, Bandages, Sutures etc.). Sterilizer can be uses even for sterilization of powders which deteriorate by heating exposure. For the wide range of product that can be treated, such sterilizer find application in Disposable Surgical Products, Para Pharmaceutical and Pharmaceutical Industry, Laboratories, Hospital and Food Processing Industries.