Post Buy Requirement
Active Power Control

Active Power Control Ahmedabad, Gujarat

Ahmedabad, Gujarat, India
Add Review

Our Products

  1. Level Controllers

    2 Products available
  2. Circuit Breaker

    1 Products available
  3. Domestic Fans, AC & Coolers

    1 Products available
  4. Starters

    1 Products available
  5. Electric Ballasts

    1 Products available
  6. Tube Light

    1 Products available
  7. Others Products 2 Products available

Our Products #3170365

We offer a complete product range of ACTIVE ELCB + MCB WITH PREVENTER and esl tube bulb

Electronic Tube Light

  • Surface Treatment Coated
  • Power Consumption 28w
  • Voltage Range 90-300 V. A.c., 50 Hz
  • P.F. >0.95
  • High Lumens Output 2450 (approx.)
  • Operates At High Frequency >20 Khz

We have garnered wide acclaim for being a trusted Manufacturer and Supplier of Electronic Tube Light from Ahmedabad, Gujarat. We offer a range of high quality Electronic Tube Light that is manufactured using quality and safe components. Though available in various models, clients can avail from us customized order of tube light according to their requirement.

Features :

  • 45% Energy Saving
  • Flicker free & Instant start
  • Eliminates audible noise and starts instantly with flicker free operation
  • Less cathode current for long life tube (No Black Ends)
  • Has a long life expectancy, rated life of tube is up to 5000 burning hours
  • Low harmonic distortion
  • Super slim design
View Complete Details

ACTIVE ELCB + MCB WITH PREVENTER

ACTIVE ELCB + MCB WITH PREVENTER [Earth Leakage Circuit Breaker with Preventer]A high sensitive current operated Earth Leakage Circuit Breakers are designed to give protection by disconnecting the power supply against risk of dangerous & possible lethal electric shocks. It detects dangerous leakage current exceeding the generally accepted safe limit of 30mA & isolates the effected section of installation. It confirms to BS standard 4293: 1983. It is a highly sensitive and high speed response unit. Sensitivity-based on rated tripping level from 3mA to 30mA. Response speed-Within 30m sec. of leakage exceeding set limits.HOW IT OPERATES : ACTIVE High sensitive current operated Earth Leakage Circuit Breaker incorporates an active current transformer, to sense the sum of all current to be normally zero. Normally current flowing through phase passes through the neutral through load so resultant voltage in an active transformer is zero. ln case of any leakage to earth, core balance transformer senses as unbalance & small signal voltage is generated in secondary winding which is fed to solid state electronic circuit of ELCB. This is amplified and immediately activates the tripping mechanism of the unit. Hence resulting in switching off and isolating the defective installation.This highly sophisticated Earth Leakage Circuit Breaker system (ELCB), based on the latest & ultimate in electronics design; is specifically engineered to protect you from dangerous electric shock and your equipment from High Voltage, Low Voltage, Overload and Short circuit. There are LED indications provided on the front panel display which informs you that your ELCB has sensed Fault and display its Fault status with LED indication along with Emergency Light an
View Complete Details

Earth Leakage Circuit Breaker

  • Material Plastic
  • Warranty 1 Year
  • Automation Grade Automatic
  • Rated Voltage 230V
  • Rated Current 6-100a
  • No. of Poles 2

Our company is a well known Manufacturer and Supplier of Earth Leakage Circuit Breaker [ELCB] from Ahmedabad, Gujarat. These breakers are highly sensitive and can easily detect current leakage before it becomes a big risk. Customers can be assured of receiving a quality Earth Leakage Circuit Breaker  [ ELCB ] from us that conforms to BS standard 4293: 1983.

Highlights :

  • A high sensitive current operated Earth Leakage Circuit Breaker  [ ELCB ]
  • Specially designed to give protection by disconnecting the power supply against risk of dangerous & possible lethal electric shocks
  • Detects dangerous leakage current exceeding the generally accepted safe limit of 30mA & isolates the effected section of installation
  • Confirms to BS standard 4293: 1983
  • Highly sensitive and high speed response unit
  • Sensitivity-based on rated tripping level from 3mA to 30mA
  • Response speed-Within 30m sec. of leakage exceeding set limits


How It Operates?ACTIVE High sensitive current operated  Earth Leakage Circuit Breaker  [ ELCB ] incorporates an active current transformer, to sense the sum of all current to be normally zero. Normally current flowing through phase passes through the neutral through load so resultant voltage in an active transformer is zero. In case of any leakage to earth, core balance transformer senses as unbalance & small signal voltage is generated in secondary winding which is fed to solid state electronic circuit of ELCB. This is amplified and immediately activates the tripping mechanism of the unit. Hence, resulting in switching off and isolating the defective installation. This highly sophisticated Earth Leakage Circuit Breaker system (ELCB), based on the latest & ultimate in electronics design; is specifically engineered to protect you from dangerous electric shock and your equipment from High Voltage, Low Voltage, Overload and Short circuit. There are LED indications provided on the front panel display which informs you that your ELCB has sensed Fault and display its Fault status with LED indication along with Emergency Light and Audible Emergency Signal - Siren. After fault recovery, control circuit having inbuilt time delay will be activated within 5 seconds instantly and ELCB will be ON automatically-Fully Automatic (self start).

PROTECTIONS

MODE E/L = EARTH LEAKAGE O/L = OVERLOAD H/V = HIGH VOLT.
L /V =  LOW VOLT.
WORKING Available Available Available
BYPASS(1) × Available Available
BYPASS(2) × × ×

RATINGS

PARAMETERS
Particulars 1-phase 3-phase
Rated  Voltage 230±10% Volt A.C. 50Hz. 415±10% Volt A.C. 50Hz.
Rated  Load Current 0-32  Amp (Adjustable) 0-32  Amp (Adjustable)

EXCLUSIVE HIGH PERFORMANCE FEATURES

Protection 1 Earth Leakage Current 3 - 30mAmp. (Adjustable) For Shock Protection
2 Overload   0 - 32 Amp Overload set. For equipment Safety
3 Short  circuit Inbuilt  Overload function For  total premises Safety
4 High Voltage Cut-off / Cut-in Above  305 Volt. A.C./ Below  290 Volt. A.C. For equipment Safety
5 Low Voltage Cut-Off / Cut-in Below  160 Volt A.C. ./ Above  180 Volt. A.C. For equipment Safety
6

By Pass  Function (1)

By Pass  Function (2)

As per chart on  ELCB enclosure - metal body Semi Bypass = Bypass (1)
Fully Bypass = Bypass(2)
Facilities 7 Emergency indication Emergency Light Facility      For light up the area.
8 Emergency  Audible Signal Siren Facility It informs that there is a fault in system.
9 Fully Automatic - Self Start Within 5 second

Auto Reset

 

10 Fault  Indication LED Display On  front  panel display
11 Tripping Time  Less than 30mSec.   High speed  Responses
12 Highly sophisticated Control Circuit operated Relay mechanism High precision available For instant tripping & isolates the defective installation
13 TEST  Function Push the button  ‘ TEST ’ to check the healthy function of ELCB To confirm the Earth leakage test

View Complete Details

Esl Tube Bulb

We offer esl tube bulb exclusive high performance features :protections sr.no. Particulars parameters (1-phase) 1earth leakage current3 - 30mamp. (adjustable)for shock protection 2overload 0 - 32 amp overload set.For equipment safety 3short circuit inbuilt overload functionfor total premises safety 4high voltage cut-off cut-inabove 305 volt. A.c. Below 290 volt. A.c.For equipment safety 5low voltage cut-off cut-inbelow 160 volt a.c. . Above 180 volt. A.c.For equipment safetyfacilities6by pass & functionas per chart on elcb enclosure - metal bodysemi bypass = bypass fully bypass = bypass 7emergency indication emergency light facility for light up the area. 8emergency audible signalsiren facilityit informs that there is a fault in system. 9fully automatic - self startwithin 5 secondauto reset 10fault indicationled displayon front panel display 11tripping time less than 30msec. high speed responses 12highly sophisticated control circuit operated relay mechanismhigh precision available for instant tripping & isolates the defective installation 13test functionpush the button test to check the healthy function of elcb to confirm the earth leakage testsafety check unit : to ensure that the active elcb + mcb with preventer is always in top working condition, a test circuit is provided with the system. By simply using the test button provided on the front side, artificial leakage is created and electronic circuit senses the leakage current & trips the elcb+mcb with preventer in order of sensitivity.
View Complete Details

Electronic Ballast

  • Operating Temperature -25 +85deg C, -70 +40deg C
  • Driven Type Electric
  • Power Consumption 36w
  • Voltage Range 100-300 V. A.c., 50 Hz
  • Operates At High Frequency >20 Khz
  • P.F. >0.95

Our firm is a reliable Manufacturer and Supplier of Electronic Ballast based in Ahmedabad, Gujarat. The Electronic Ballast we provide is greatly preferred by our clients for consuming less power and having a flicker free operation. Clients from all over India can avail from us bulk orders of Electronic Ballast at extremely affordable price.

Features :

  • 40% Energy Saving
  • Eliminates audible noise and starts instantly with flicker free operation
  • Less cathode current for long life tube (No Black Ends)
  • Has a long life expectancy, rated life of tube is up to 5000 burning hours
  • Low harmonic distortion
  • Radio Frequency Interference (RFI) / Electro Magnetic Interference (EMI) filters in commercial and industrial models to avoid electrical noise on to the power line which can interfere to other equipments.
View Complete Details

Automatic Water Level Controller

  • Type Automatic
  • Certification CE Certified
  • Application Control Liquid Level
  • Voltage 220V
  • Power 1-3kw
  • Driven Type Electric
  • Warranty 2 Years
  • Phase Single Phase

Our company has carved a niche as an established Manufacturer and Supplier of Automatic Water Level Controller from Ahmedabad, Gujarat. Automatic Liquid Level Controller offered by us is fully automatic and utilizes the latest technical advancements for a flawless performance. Customers can rely us for delivering small or large quantities of this product to any part of the country.

Highlights :

  • Based on the latest in electronic IC technology, designed to eliminate waste of water, save energy and work quietly & efficiently without the need of manpower
  • Fully automatic - no manpower required, As LLCs will automatically sense required levels and START/STOP pumps
  • Avoid overflow
  • Protection against dry running
  •  Energy saving - as pumps automatically switch off at required levels. Higher durability and longer life - since completely electronic and no mechanical systems
  • All probes are Stainless Steel to guard against corrosion

 

Models :

  • LLC -1 : Suitable for 1-phase motor up to 25Amp load
  • LLC -1/S : Suitable for 1-phase submersible pump panel board up to 25Amp load
  • LLC-3 : Suitable for any 3 -phase motor with DOL, FASD & SASD starter.


How to Use?

  • For underground to overhead tank: To use unit for both tanks, all connections (OH, OL, C, UL, UH) should be used. Whenever liquid level in underground tanks falls below set low level, it switches off the pump-set. Pumping will restart only when liquid level reaches to set high level or above that and only if demanded by overhead tank. Low level in underground tank to be set above foot valve to avoid dry running of pump-set. Now motor operation will be as per level in overhead tank.
  • For Overhead Tank: To use unit for controlling levels in overhead tank, short point C, UL & UH. Now whenever level in overhead tank falls below set low level, unit operates pump-set automatically and when liquid level reaches to high level, it stops motor pump-set. Motor will restart only when liquid level falls below low level.
  • For Underground Tank: To use the unit for underground tank, keep terminals OH & OL open. Now when liquid level falls below set low level, the unit switches off the pump-set & it will switch on the pump-set when liquid level reaches to high level.

 

Installation Guide :

Install the Liquid Level Controller at suitable place. Protect the unit from rainfall, sunlight and waterfall.

Fix-up High, Low & Common sensors in Overhead tank considering following points.

  • High sensor should be installed at maximum level at which you want to stop the pump. Keep a sensor probe slightly lower than over flow pipe level.
  • Low sensor should be installed at level which you want to start the pump. Low sensor should be such that it will keep some reserve stock in tank. Distance between Low and High sensor should not be very less otherwise it operates pumps frequently.
  • Keep Ground sensor at lowest level in the tank.


Fix-up High, Low & Common sensors in Underground tank considering following points.

  • Keep the High sensor at middle level in Underground tank for better result.
  • Keep the Low sensor at slightly higher level than foot valve. Pump will be stopped if water goes down below this level even if Overhead tank is empty. Push the ‘Manual reset’ push button to switch-ON the motor pump in this situation.
  • Keep the distance 6 inch between Low sensor & Ground sensor in Underground tank for preventing the motor ON-OFF frequently.
  • Keep Ground sensor at lowest level in the tank.

Keep the Ground, Low and High sensors away from incoming waterfall in both tanks. Use the PVC pipe having 1 inch diameter with some ducts(holes) through the pipe to keep the real level of water in each tank. Please see the connection diagram attached on Water Level Controller to fix up the sensors in both tanks.

Clean the all sensor probes in Overhead and Underground tank at least once a year for better function of the Water Level Controller.

Specifications

System Voltage

LLC-3

LLC-1, LLC-1/S

415/110v/230V.± 20%, 50Hz.

230 V.± 20%, 50Hz.

Contact Rating

LLC-3

LLC-1/S

LLC-1

1A at 415 V. A.C. at PF: 0.5.

20A at 230V. A.C. (Resi.),  25A Start Relay. 

20A at 230V. A.C. (Resi.).

Sensing Element -

For all models Stainless steel sensors  or 

Magnetic sensors for non-conductive liquid.

Terminal

LLC-3 

LLC-1, LLC-1/S

Bakelite moulded.

Bakelite moulded.

Reset                     For all models Auto & Manual (For water levels)
Dimensions

LLC-3

LLC-1/S

LLC-1 

166 × 145 × 90 mm

166 × 145 × 90 mm

166 × 145 × 90 mm

Mounting

 LLC1

LLC-1/S

LLC-3 

155 × 127 mm

155 × 127 mm

155 × 127 mm

Cable for probes For all models 3 cores, 16/20 size
Maximum  Cable length  For all models 200 meters
Indications Overhead tank - High level,  Motor On,  Underground tank – Low level -

Coding In Diagram

OH Overhead tank - High level. UH Underground tank - High level
OL Overhead tank - Low level. UL Underground tank - Low level 
C Common. - -

Graph


Download Detail File : Click Here
View Complete Details

Active Automatic Liquid Level Controller

Active presents to you one of the most advanced , sophisticated & innovative systems for automatic control of liquid levels. It is based on the latest in electronic ic technology, designed to eliminate waste of water, save energy and work quietly & efficiently without the need of manpower.Fully automatic - no manpower required, as llcs will automatically sense required levels and startstop pumps.Avoid overflow. Protection against dry running. Energy saving - as pumps automatically switch off at required levels. Higher durability and longer life - since completely electronic and no mechanical systems. All probes are stainless steel to guard against corrosion.Models :llc -1 : suitable for 1-phase motor up to 25amp load.
View Complete Details

Single Phase Motor Starter

  • Type Automatic
  • Certification CE Certified
  • Voltage 220V
  • Automatic Grade Manual
  • Power 1-3kw
  • Driven Type Electric
  • Phase Single
  • Current Type AC
  • Speed 1000-2000rpm

We are an eminent Manufacturer and Supplier of Single Phase Motor Starter from Ahmedabad, Gujarat. The Electronic Motor Starter offered by us is able to protection against spikes in voltage or current or against power failure. Owning to our efficient logistic system, we make sure that customers receive their order of Single Phase Electronic Motor Starter within the postulated time.

Highlights :

  • Provide protection to motor against over current, high voltage, low Voltage and isolates the motor in case of power failure
  • Available in elegant, dust proof ABS plastic enclosure with white color

Specifications

Operating voltage 150 to 280V.
Current range Amp.  2-5 Amp, 4-10 Amp, 8-14 Amp, 10-16 Amp, 8 - 25 Amp
Overload tripping As per inverse time current characteristic.

Low / High Voltage   Cut - Off   

Low / High Voltage  Cut - In

150V - 280V.

155V - 270V.

On- Off / Reset  By manual push button.
Indications  Green - Motor On,   Red – Overload, High/Low

Details

Model Description
ASW For conventional single phase motors like Grinders, Polishers, Wood working machines etc. Provides overload & high/low voltage cut-off for any other home appliances.
ASW - T For Compressors / Air conditioners / Water coolers, Exhaust fans, Provides three minutes time delay in auto restart and manual facility.
ASW - D

For unattended pumps. Build in dry-run protection with 30% to 70% adjustable dry - run current.      

 

View Complete Details

Electronic Fan Regulator

  • Material Plastic
  • Certification ISI Certified
  • Application Fan Use
  • Color White
  • Automatic Grade Manual
  • Puncture Voltage 100-200W
  • Electricity Volume 5

We are a reputed Manufacturer and Supplier of Electronic Fan Regulators from Ahmedabad, Gujarat. Made from high grade materials and having a robust design, our Electronic Fan Regulators are able to consume power easily and are available in different designs. Customers from all over India can acquire Electronic Fan Regulators from us at really reasonable rates.

Highlights :

  • Regulators are provided with ON-OFF switch and snubber circuit network
  • Inductor capacitor network provides electrical noise suppression
  • Low voltage setting is kept 90 V± 5v for 240V A.C.
  • Standard tapped resistance fan regulators dissipate power in resistance & allows less power for fan to reduce speed of fan. For lower speed of fan, power is wasted in resistance
  • Solid state fan regulators chops AC supply in both positive and negative half cycle
  • Power dissipation in solid state switching device is very less. Power saving will be about 50% at low speed to 0% at maximum speed
  • Solid state fan regulators are used for fan, dimming light, table lamp, portable fan, exhaust fan. Can be also used in hand drills, water coolers & small universal motors, tension motors, heaters etc.
  • Models are available with 400W, 600W, 1000W, 1500W and 2000W rating

 

Features :

  • Hum free
  • 40% Power saving
  • 5 Step Linear output
  • Excellent look
  • Suitable to all brands of ceiling fans
  • Long life
  • Virgin ABS heavy plastic body
  • Fully rotate.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us