Our Products
Our Complete range of products are Laboratory Refrigerator, SOLAR LABORATORY REFRIGERATOR, medical refrigerators, Blood Bank Refrigerator and Blast Freezer.
Laboratory Refrigeratorfrom WEIBER are designed for a wide variety of applications from biological to media and reagent storage. These are used to cool samples or specimens for preservation. These differ from standard refrigerators used in homes or restaurant because they need to be totally hygienic and completely reliable. To achieve a high degree of accuracy the refrigerator needs air to circulate and a fan to maintain an even temperature at all times. The fan turns off when the door is open to prevent cold air from blowing out of the unit. OurLab Refrigeratorfeature separate compartments to prevent cross contamination and can hold specific medical supplies.
Our refrigerators feature a thick, thermal glass door and insulation plus a heavy-duty, auto or cycle defrost refrigeration system, which helps keeps a tight temperature range.
SINGLE GLASS DOOR REFRIGERATOR
VOLUME Cu. Ft. | INETRIOR DIMENSIONS (WXDXH)INCHES | EXTERIOR DIMENSIONS (WXDXH)INCHES |
4.9 | 20 x 20.5 x 20 | 24 x 26 x 33.4 |
11.5 | 20 x 21.75 x 52.4 | 24 x 29.4 x 73.6 |
23.3 | 24 x 29 x 58 | 28 x 37.2 x 79.2 |
29.2 | 30 x 29 x 58 | 34 x 37.2 x 79.2 |
Customizable sizes are also available
VOLUME Cu. Ft. | INETRIOR DIMENSIONS (WXDXH)INCHES | EXTERIOR DIMENSIONS (WXDXH)INCHES |
45.8 | 52.5 x 26 x 58 | 56.5 x 34.5 x 79.1 |
51.1 | 52.5 x 29 x 58 | 56.5 x 37.2 x 79.2 |
Customizable sizes are also available
Material | Door: Glass / PERSPEX Exterior: PCRC / Stainless steel Interior : stainless steel |
Temperature Range | Temperature Range 2° to 6° C |
Temperature Control | Microprocessor |
Display | Digital |
Defrost | Automatic |
Refrigerant | CFC -free R134A |
Shelves | 2/3/4/6/8/10 (size specific) |
Electrical requirements | 220/230V , 50HZ |
WEIBER now introduces solar powered editions of refrigerators.
Solar Laboratory Refrigerator is one such application, using solar energy to convert to electrical energy to cool the refrigerator. Solar Lab Refrigerator is available in various sizes to meet our customers needs. We also customize refrigerators according to different requirement of capacity and ranges.
Solar power is the latest trend in technology to minimize the need of electrical energy generated. And even in rural and low lying areas where electricity does not reaches, the use of electrically operated refrigerators create a problem. A solution to such problem are solar refrigerators that get cooled through sunlight.
They use a combination of solar panels and lead batteries to store energy for cloudy days and at night in the absence of sunlight to keep their contents cool.
SINGLE GLASS DOOR REFRIGERATOR
VOLUME Cu. Ft. | INETRIOR DIMENSIONS (WXDXH)INCHES | EXTERIOR DIMENSIONS (WXDXH)INCHES |
4.9 | 20 x 20.5 x 20 | 24 x 26 x 33.4 |
11.5 | 20 x 21.75 x 52.4 | 24 x 29.4 x 73.6 |
23.3 | 24 x 29 x 58 | 28 x 37.2 x 79.2 |
29.2 | 30 x 29 x 58 | 34 x 37.2 x 79.2 |
Customizable sizes are also available
DOUBLE GLASS DOOR REFRIGERATOR
VOLUME Cu. Ft. | INETRIOR DIMENSIONS (WXDXH)INCHES | EXTERIOR DIMENSIONS (WXDXH)INCHES |
45.8 | 52.5 x 26 x 58 | 56.5 x 34.5 x 79.1 |
51.1 | 52.5 x 29 x 58 | 56.5 x 37.2 x 79.2 |
Customizable sizes are also available
CABINET TYPE
Volume | Outer dimension(WXDXH)(INCHES) | Inner dimension(WXDXH)(INCHES) |
150 | 24X41X27 | 20X20X21 |
260 | 24X57X27 | 20X36X23 |
380 | 28X63X34 | 24X42X23 |
330 | 28X57X28 | 24X36X23 |
435 | 28X69X34 | 24X48X23 |
550 | 28X82X28 | 24X61X23 |
670 | 28X95X33 | 24X74X23 |
Customizable sizes are also available
Power requirements | 230V/50Hz. |
Energy sources | 12VDC-12VDC |
Temperature range | 2-8oC |
Temperature accuracy | ±0.5oC |
Hold over time | 2 hours to rise above 6 oC |
General Applications | 10hours for all packs to reach below 6 oC |
Refrigerant used | R-134a(CFC free) |
Width of insulation wall | 120mm |
Display | LCD |
Safety thermostats | |
Automatic temperature setting | Yes |
Adjustable limits | Yes |
Medical Refrigeratorare designed to store materials under low temperature condition for hospital, epidemic station, blood bank, research institute, university, biological pharmaceutical industry and gene engineering, etc. The refrigerator also also known asPharma Refrigerator.
Pharmaceutical Refrigeratorare designed specifically to meet the demanding temperature requirements for safe vaccine storage. ourMedical Refrigeratorswill safely store influenza (LAIV, FluMist);rotavirus (RV1, Rotarix and RV5, RotaTeq); typhoid (Ty21-A, Vivotif); yellow fever (YF-Vax); VAR (Varivax); ZOS(Zostavax); and MMRV (ProQuad) and other types of vaccines.
SINGLE GLASS DOOR REFRIGERATOR
VOLUME Cu. Ft. | INETRIOR DIMENSIONS (WXDXH)INCHES | EXTERIOR DIMENSIONS (WXDXH)INCHES |
4.9 | 20 x 20.5 x 20 | 24 x 26 x 33.4* |
11.5 | 20 x 21.75 x 52.4 | 24 x 29.4 x 73.6 |
23.3 | 24 x 29 x 58 | 28 x 37.2 x 79.2 |
29.2 | 30 x 29 x 58 | 34 x 37.2 x 79.2 |
Customizable sizes are also available
DOUBLE GLASS DOOR REFRIGERATOR
VOLUME Cu. Ft. | INETRIOR DIMENSIONS (WXDXH)INCHES | EXTERIOR DIMENSIONS (WXDXH)INCHES |
45.8 | 52.5 x 26 x 58 | 56.5 x 34.5 x 79.1 |
51.1 | 52.5 x 29 x 58 | 56.5 x 37.2 x 79.2 |
Customizable sizes are also available
Material | Door: Glass/Perspex Exterior: PCRC / Stainless steel Interior : stainless steel |
Temperature Range | 2° to 8° C |
Temperature Control | Microprocessor |
Display | Digital |
Defrost | Automatic |
Refrigerant | CFC -free R134A |
Shelves | 2/3/4/6/8/10 (size specific) |
Electrical requirements | 220/230V , 50HZ |
Blood Bank Refrigeratorare conceptualized and designed to meet the challenging requirements of modern day blood banks to efficiently conserve whole blood and its derivatives beside variety of other products such as vaccines, primers, culture media etc. It ensures freshness and integrity of blood and blood components. Ourblood bank refrigeratorsare made of corrosion free metal components with advance poly urethane insulation ensuring maximum thermal efficiency and durability.
We specialize in both standard and customized models ofVaccine Refrigeratorsspecially designed to meet various special requirements of our customers across India and abroad.
Capacity (L) | Internal size (D*W*H) mm | External size (D*W*H) mm | Blood capacity |
88 | 400*350*600 | 530*580*1150 | 40-60/bags |
268 | 550*525*910 | 680*760*1550 | 120 150/bags |
358 | 600*550*1025 | 735*785*1700 | 180-220/bags |
588 | 625*600*1500 | 755*840*2200 | 250-300/bags |
Customizable sizes are also available
4.9 | 20 x 20.5 x 20 | 24 x 26 x 33.4* |
11.5 | 20 x 21.75 x 52.4 | 24 x 29.4 x 73.6 |
23.3 | 24 x 29 x 58 | 28 x 37.2 x 79.2 |
29.2 | 30 x 29 x 58 | 34 x 37.2 x 79.2 |
Customizable sizes are also available
DOUBLE GLASS DOOR REFRIGERATOR
VOLUME Litres | INETRIOR DIMENSIONS (WXDXH)mm | EXTERIOR DIMENSIONS (WXDXH)mm | Blood capacity |
1271 | 1397*1480*606 | 1505*2020*750 | 728 bags |
1586 | 1334*737*1473 | 1435*925*2012 | 770 bags |
Customizable sizes are also available
Material | Door: Glass/Perspex Exterior: PCRC / Stainless steel Interior : stainless steel |
Temperature Range | 2° to 8° C |
Temperature Control | Microprocessor |
Display | Display Digital |
Defrost | Automatic |
Refrigerant | CFC -free R134A |
Shelves | 2/3/4/6/8/10 (size specific) |
Electrical requirements | 220/230V , 50HZ |
Blast Freezerare used for instant freezing of blood plasma, food products etc. it freezes the blood plasma and other samples to -20oC in not less than 60 min.Chest Freezeroffer a breakthrough insample preparation for use prior to cold storage including flexible design, accelerated air flow and a self-contained refrigeration system. Slow freezing forms big ice crystals in the product. The crystals are forming cells and destroy the structure of the product but inblast freezerFast freezing forms many small ice crystals which keeps the original product safe.
UPRIGHT MODEL
Volume (L) | Exterior dimension (WXDXH)mm | Interior dimensions (WXDXH)mm |
120 | 846 x 1981 x 940 | 584 x 978 x 429 |
610 | 800 x 815 x 945 | 660 x 640 x 330 |
1000 | 800 x 815 x 1645 | 660 x 640 x 870 |
Customizable sizes are also available.
CABINET MODEL
Volume (L) | Exterior dimension (WXDXH)mm | Interior dimensions (WXDXH)mm |
180 | 860*1160*1120 | 500*500*640 |
292 | 1753*737*1080 | 894*483*674 |
380 | 1320*1160*1120 | 1000*500*640 |
Customizable sizes are also available.
Temperature range | -0°C to -2°C |
Accuracy | ±1 °C |
Power Requirements | 220/230V, 50Hz |
Controller | Microprocessor based |
Chart recorder | 7-day optional |
Insulation | Polyurethane foam |
Compressor | Air cooled |
Display | LCD |
Defrost option | Provided |
Specimen protection | Provided |
Outer construction | Thick PCRC |
Inner construction | Stainless steel |
CRYOGENIC FREEZERwith temperature range -140oC to -155oC offer mechanical cryopreservation for long-term biological storage. Cryopreservation is the process where cells or whole tissues are preserved by cooling to sub-zero temperatures. The freezer also known asCryogenic Storage Freezer. At low temperatures, any enzymatic or chemical activity which might cause damage to the material is effectively stopped. Liquefied gases, such as liquid nitrogen and liquid helium, are used in many cryogenic applications. Liquid nitrogen is most commonly used. Cryogenics is used in applications such as cord blood preservation and livestock breeding for the following materials:
Examples include:
semen cryopreservation
Blood
Stem cells. It is optimal in high concentration of synthetic serum, stepwise equilibration and slow cooling.
Umbilical cord blood
Tissue samples like tumors and histological cross sections
Eggs (oocytes) in oocyte cryopreservation
Embryos at cleavage stage (that are 2, 4 or 8 cells) or at blastocyst stage, in embryo cryopreservation
Ovarian tissue in ovarian tissue cryopreservation
Plant seeds or shoots may be cryopreserved for conservation purposes. Etc.
Volume (L) | Exterior dimension (WXDXH)mm | Interior dimensions (WXDXH)mm |
180 | 860*1160*1120 | 500*500*640 |
292 | 1753*737*1080 | 894*483*674 |
380 | 1320*1160*1120 | 1000*500*640 |
Customizable sizes are also available.
Temperature range | -140°C to -155°C |
Cooling medium | Liquid nitrogen 22-35 psi |
Accuracy | ±1 °C |
Heating rates | 0.01 °C/min to 1 °C/min |
Cooling rates | -0.01 °C/min to -5 °C/min |
Power Requirements | 220/230V, 50Hz |
Amperage | 23A |
Lid | Heavy-duty counterbalanced lid withintegrated keyed lock and insulated sublids Controller Microprocessor based |
Controller | Microprocessor based |
Chart recorder | 7-day optional |
Insulationl | Polyurethane foam |