Post Buy Requirement
AT
Delhi, India
Add Review

Our Products

  1. Industrial Ovens & Furnaces 8 Products available
  2. Laboratory Shakers 4 Products available
  3. Storage Drums, Tanks & Containers 3 Products available
  4. Autoclaves 5 Products available
  5. Measuring Instruments & Equipment 17 Products available
  6. Testing Equipments 17 Products available
  7. Laboratory Equipments 41 Products available
  8. Freezers 6 Products available
  9. Clean Room Equipment 5 Products available
  10. Others 74 Products available

Clean Room Equipment #1802199

Clean Room Air Shower

ThePersonnel Air Showerfrom Weiber are fully self-contained units, designed to provide complete decontamination solutions for various clean room applications. They are ideally installed at the entrance of a clean room or controlled environment chamber to minimize the entry of dust and particulate matters inside the clean room via the clothes and skin surfaces of the personnel. OurClean Room Air Showerfeature programmable operating modes for flexible application and microprocessor based controller for precise supervision of the operating parameters. They use highly efficient pre-filters and HEPA filters for maintaining highly sterile working environments and an integrated fan/blower assembly to provide high velocity air streams for maximum scrubbing action against dust and particulate matters adherent on the exposed skin, clothes and material surfaces.

3 types of configurations are available:

One side flow:The unit allows one-way operation, with the clean side door locked and the grey side door unlocked at the idle state. This mode of operation helps in controlling the flow of traffic in and out of the clean room for maintaining maximum sterility in the working area.

Two side flow:The unit allows both side flows, allowing theAir Showersto be activated in both the directions. The user can exit through the clean room door or the grey side door, without compromising the sanctity of the clean air environment. This mode of operation prevents the egress of harmful contaminants from the clean room to the outside environment, making the unit particularly useful in pharmaceutical industries, animal research laboratories and other applications that require working with harmful and biohazardous substances.

Tower flow:the flow is from the upper roof of the shower.

The fully automatic operation prevents the need for manual switching on/off of the air shower cycle and the shower time, providing an unmatched ease of use. The incorporated safety features such as magnetically operated interlocked doors, the auto reset feature and an array of alarms and LED indicators for actual and set parameters prevent accidental lockouts and ensure smooth functioning of the unit.

  • High velocity shower jets in excess of 20 m/s ensure efficient scrubbing action to remove particulate matter.
  • Programmable operating modes
  • Solid state programmable microprocessor based controls for various operating parameters
  • Fully washable pre-filters remove around 85% of particulate matters, therefore reducing the load on HEPA filters and increasing their efficiency and life span
  • Highly efficient HEPA filters with around 99.99% filtration efficiency for removing particles as small as 0.3 microns and larger.
  • Floor matting operated switch for sequential operation of the air shower
  • Multidirectional air flow
  • Adjustable air nozzles
  • Permanently lubricated direct drive centrifugal motors and efficient blowers for maintaining appropriate face velocities of the air (6000 ft/min + 20 feet), while producing minimum vibrations and noise (less than 60 db)
  • Indicator lights on both sides of the air shower for regulation of traffic within the cubicle
  • Emergency buttons on both sides of the air shower to prevent accidental lock-outs
  • Interlocked doors minimize any chances of contamination
  • Door interlocks operate on the magnetic system
  • Hinged motor/blower compartment access panels made of coated aluminium
  • Tamper proof junction box, placed on top
  • Emergency switch off button with audible alarm located within the shower cubicle

Constructions Stainless Steel
Operation Time (Adjustable) 0-9,990 seconds
Pre Filter Washable pre-filter unit (Non-WovenSynthetic Polyester)
HEPA Filters Glass pleated non-woven fabric filter having 99.99% efficiency 0.3 micron particle size.
Air Flow One side/two side/tower flow/multidirectional
Face velocity 6000 ft./min + 20 feet
Air Flow Control Solid State Control Unit
Illumination Fluorescent light illumination greater than 800 lux on work table
Blower Assembly Centrifugal lubricated bearing type ISI marked assembly
Noise level Noise level less than 60 dB
Add on Features Sequential feature operation by door mat magnetic switch.
Power Requirements 500 watts – 950 watts (Model specific)
Nominal voltage 220-230 Volts,
Frequency 50/60 Hz
View Complete Details

Air Shower

Material Handling Air Showerare self-contained units, installed at the entrance of a clean room and other controlled environment chambers for minimizing the entry of dust particles and other particulate matters into the working area. TheMaterial Handling Air Showeris designed to provide and maintain clean room conditions for research applications and particle sensitive manufacturing processes. These energy efficient units are fully self-contained and well equipped to provide and sustain a highly sterile working environment. Our versatileAir Showersare quite adept at controlling the level of contamination for particle sensitive processes such as disc drive and semiconductor manufacturing, pharmaceutical drug testing and for research applications involving molecular biology and biochemical experiments, cell and tissue culture experiments etc.

They are available in both standard and customized designs to suit the requirements of the industry. The entireair showerassembly is HEPA/ULPA filtered, pre-wired and tested, ready to use with a simple plug-in, therefore providing an unmatched ease of operation. Moreover, the use of high quality construction materials ensures unparalleled manufacturing quality, whereas the highly efficient blowers and motors ensure long lasting dependable results.

3 types of configurations are available:

One side flow:The unit allows one-way operation, with the clean side door locked and the grey side door unlocked at the idle state. This mode of operation helps in controlling the flow of traffic in and out of the clean room for maintaining maximum sterility in the working area.

Two side flow:The unit allows both side flows, allowing the air showers to be activated in both the directions. The user can exit through the clean room door or the grey side door, without compromising the sanctity of the clean air environment. This mode of operation prevents the egress of harmful contaminants from the clean room to the outside environment, making the unit particularly useful in pharmaceutical industries, animal research laboratories and other applications that require working with harmful and biohazardous substances.

Tower flow:the flow is from the upper roof of the shower.

  • Programmable operating modes
  • Programmable mode of operation, pre-purge and shower time
  • Floor matting operated switch for sequential operation of the air shower
  • Fully washable pre-filters capable of removing around 85% of particulate matters
  • Highly efficient HEPA filters with around 99.99% filtration efficiency for removing particles as small as 0.3 microns and larger.
  • Both the doors are Interlocked and magnetically operated to prevent them from opening at the same time
  • The auto reset feature unlocks the doors to prevent accidental lockouts
  • The reset default function resets the program settings to default values
  • Microprocessor based controls for the set parameters, detection of errors and their display
  • The clean room/grey room settings can be reversed via microprocessor based controllers, eliminating the need for physical reorientation of the unit.
  • Permanently lubricated direct drive centrifugal motors and efficient blowers capable of maintaining appropriate face velocities of the air (6000 ft/min + 20 feet)
  • Multidirectional air flow for better reachability
  • Emergency override buttons on both sides of the air shower to release the doors even when the air shower cycle has not completed
  • Indicator lights for open doors
  • LED indicators for interlock and shower sequence
  • An administrator PIN can be set to prevent unauthorized access to the air shower settings
  • A maintenance function operates the fan continuously for service checks and air velocity measurements
  • Versatile usage
  • Ergonomic design
  • Reduced vibration levels
  • Low noise level < 60 db
  • Programmable operation
  • Calibration and protocol documentation
  • Conforms to the US Federal Standards

Constructions Stainless Steel
Operation Time (Adjustable) 0-9,990 seconds
Pre Filter Washable pre-filter unit (Non-WovenSynthetic Polyester)
HEPA Filters Glass pleated non-woven fabric filter having 99.99% efficiency 0.3 micron particle size.
Air Flow One side/two side/tower flow/multidirectional
Face velocity 6000 ft./min + 20 feet
Air Flow Control Solid State Control Unit
Illumination Fluorescent light illumination greater than 800 lux on work table
Blower Assembly Centrifugal lubricated bearing type ISI marked assembly
Noise level Noise level less than 60 dB
Add on Features Sequential feature operation by door mat magnetic switch.
Power Requirements 500 watts – 950 watts (Model specific)
Nominal voltage 220-230 Volts,
Frequency 50/60 Hz
View Complete Details

Vertical Laminar Air Flow

Vertical Laminar Air Floware conceptualized to provide a work area completely bathed in high efficiency perfect air, which is free from any kind of particulate contamination or impurities. These units are ideally suited in all the applications, requiring protection of biological specimens or products from the possible contamination during the process or test. OurLaminar Air Flow Benchis fast gaining popularity in other fields, such as pharmaceutical production, electronic industries and various other manufacturing applications.

A vertical clean bench pushes air through a HEPA filter which is located at the top of enclosure. The air is directed downward onto the work surface at a constant speed.

It is useful for various works that require maintenance of the cleanness and purity like plant tissue culture, examination and experimentation of precision electronic parts, medical science, entomology, pharmacy, agriculture sector, seed science, veterinary science.

A vertical clean bench, on the other hand, offers a pivoting glass sash as a safety measure. This sash offers personal protection and a physical barrier when working with chemicals. Vertical clean benches are common place in microbiology, forensic, biotech and many other industries, which utilizes them during procedures that require clean work area.

  • Durable & cost effective
  • Fluorescent tube light
  • HEPA filter /ULPA filters that allows unidirectional air flow preventing recirculation of molecules.
  • No gaps and joints to prevent accumulation of germs.
  • Air filters made up of mini plated non-woven fabric.
  • Balanced motor static as well as dynamic
  • 99.997% efficiency at 0.3 particle
  • Transparent Front Door (5mm)
  • Static Pressure Manometer
  • Built in U.V. Germicidal Light
  • Conforms to US Federal Standard 209 B
  • Microprocessor based controls (HMI+PLC as an option)
  • Aesthetically designed-Designed according to the standards and principles underlining industrys aesthetic values.
  • Corrosion Resistant interior and exteriors-Corrosion resistant coatings like epoxy coatings are applied inside and outside the laminar air flow to prevent against degradation due to moisture, salt spray, oxidation or exposure to a variety of environmental or industrial chemicals/ corrosive agents.
  • Energy Efficient WEIBER laminar air flow uses less energy to provide the same level of performance, comfort and convenience, thus making it energy conserving.
  • Sturdy Constructionlaminar air flow are built with robustness to withstand stress and strain, giving it long life and ability to perform in extreme stress environments.

Cabinet construction SS-304/PCRC SHEET
Frequency 50Hz
Nominal voltage 220-230 volts
Air flow Unidirectional
Noise pressure(dB) (A) <54dB
Pre filter unit Washable pre filter unit
Illumination Fluorescent light illumination greater than 800 lux
Power Requirements 500-750 watts
View Complete Details

Horizontal Laminar Air Flow

Horizontal Laminar Flowworkstations are designed to protect the product within the work area from airborne particulates in the ambient air. The regulated efflux of custom made laminar airflow supplies the work zone with ISO Class 5 air cleanliness to offer the best product production by a clean bench in the industry. TheHorizontal Laminar Flowworkstations pushes the air through a HEPA filter and directs the filtered air horizontally over the work surface at a constant speed, toward the operator.

Our versatile unit is useful for various works that require maintenance of the cleanness and purity like plant tissue culture, examination and experimentation of precision electronic parts, medical science, entomology, pharmacy, agriculture sector, seed science, veterinary science.

Horizontal Laminar Air Flowgenerally have a taller and therefore a larger loading and working area. This allows for instruments, like microscopes to be placed inside. They are typically the preferred selection for plant tissue culture, media plate preparation, electronics inspection, medical device assembly and pharmacy drug preparation. Because they do not provide protection to the user, they should not be used in conjunction with biohazardous material, toxins or radionuclides. One of the key benefits is the absence of a sash, which is an advantage when placing instruments and equipment inside. This cabinet also known asLaminar Air Flow Cabinet.

  • Durable & cost effective
  • Fluorescent tube light
  • HEPA filter /ULPA filters that allows unidirectional air flow preventing recirculation of molecules.
  • No gaps and joints to prevent accumulation of germs.
  • Air filters made up of mini plated non-woven fabric.
  • Balanced motor static as well as dynamic
  • 99.997% efficiency at 0.3 particle
  • Transparent Front Door (5mm)
  • Static Pressure Manometer
  • Built in U.V. Germicidal Light
  • Conforms to US Federal Standard 209 B
  • Microprocessor based controls (HMI+PLC as an option)
  • Aesthetically designed-Designed according to the standards and principles underlining industrys aesthetic values.
  • Corrosion Resistant interior and exteriors-Corrosion resistant coatings like epoxy coatings are applied inside and outside the laminar air flow to prevent against degradation due to moisture, salt spray, oxidation or exposure to a variety of environmental or industrial chemicals/ corrosive agents.
  • Energy Efficient WEIBER laminar air flow uses less energy to provide the same level of performance, comfort and convenience, thus making it energy conserving.
  • Sturdy Constructionlaminar air flow are built with robustness to withstand stress and strain, giving it long life and ability to perform in extreme stress environments.

Cabinet construction SS-304/PCRC SHEET
Frequency 50Hz
Nominal voltage 220-230 volts
Air flow Unidirectional
Noise pressure(dB) (A) <54dB
Pre filter unit Washable pre filter unit
Illumination Fluorescent light illumination greater than 800 lux
Power Requirements 500-750 watts
View Complete Details

CLEAN STOKER

Clean Stoker for Clean Room is designed to maintain the cleanliness integrity of clean room garments during storage. It can effectively purge and remove particles such as lint and dust ingress on the clothing fabric.

Clean Room Stoker features a quiet, direct drive, variable- speed blower mounted above a HEPA filter rated 99.99%0.3m, and delivers a continuous downstream that block the inrush of contaminants into the storage area, as a result, helps garments virtually free of particulates. Door of the scientific equipment is made available to make movable and curtain type.

  • Avoid Pollution
  • Easy installation
  • Available to make movable door and curtain type
  • Available to change the ventilation rate for need
  • Specious
  • Class Grade :Class ISO5-ISO8
  • Convenient for take clothes.
  • Easy installation & low price

Main Body Steel Plate with stoving varnish or stainless steel
Containment PVC or toughened glass
Door Curtain or movable door
Clothes Hange SUS304 or plastic
Capacity 20 pcs clean clothes
Cleanness Class 100
Overlength Class 100
Fuel Electric
Machine Type High Pressure Cleaner
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

Retailer of Clean Room Equipment from Delhi, Delhi by Acmas Technocracy Private Limited
Post Buy Requirement
AT

Acmas Technocracy Private Limited

Add Review

Our Products

  1. Laboratory Equipments 41 Products available
  2. Measuring Instruments & Equipment 17 Products available
  3. Testing Equipments 17 Products available
  4. Bath Linens 11 Products available
  5. Industrial Ovens & Furnaces 8 Products available
  6. Freezers 6 Products available
  7. Microscope 6 Products available
  8. Dryers 5 Products available
  9. Autoclaves 5 Products available
  10. Others Products 95 Products available

Clean Room Equipment

We are leaders in the market for providing best range of Clean Room Air Shower, Air Shower, Vertical Laminar Air Flow, Horizontal Laminar Air Flow and CLEAN STOKER

Clean Room Air Shower

ThePersonnel Air Showerfrom Weiber are fully self-contained units, designed to provide complete decontamination solutions for various clean room applications. They are ideally installed at the entrance of a clean room or controlled environment chamber to minimize the entry of dust and particulate matters inside the clean room via the clothes and skin surfaces of the personnel. OurClean Room Air Showerfeature programmable operating modes for flexible application and microprocessor based controller for precise supervision of the operating parameters. They use highly efficient pre-filters and HEPA filters for maintaining highly sterile working environments and an integrated fan/blower assembly to provide high velocity air streams for maximum scrubbing action against dust and particulate matters adherent on the exposed skin, clothes and material surfaces.

3 types of configurations are available:

One side flow:The unit allows one-way operation, with the clean side door locked and the grey side door unlocked at the idle state. This mode of operation helps in controlling the flow of traffic in and out of the clean room for maintaining maximum sterility in the working area.

Two side flow:The unit allows both side flows, allowing theAir Showersto be activated in both the directions. The user can exit through the clean room door or the grey side door, without compromising the sanctity of the clean air environment. This mode of operation prevents the egress of harmful contaminants from the clean room to the outside environment, making the unit particularly useful in pharmaceutical industries, animal research laboratories and other applications that require working with harmful and biohazardous substances.

Tower flow:the flow is from the upper roof of the shower.

The fully automatic operation prevents the need for manual switching on/off of the air shower cycle and the shower time, providing an unmatched ease of use. The incorporated safety features such as magnetically operated interlocked doors, the auto reset feature and an array of alarms and LED indicators for actual and set parameters prevent accidental lockouts and ensure smooth functioning of the unit.

  • High velocity shower jets in excess of 20 m/s ensure efficient scrubbing action to remove particulate matter.
  • Programmable operating modes
  • Solid state programmable microprocessor based controls for various operating parameters
  • Fully washable pre-filters remove around 85% of particulate matters, therefore reducing the load on HEPA filters and increasing their efficiency and life span
  • Highly efficient HEPA filters with around 99.99% filtration efficiency for removing particles as small as 0.3 microns and larger.
  • Floor matting operated switch for sequential operation of the air shower
  • Multidirectional air flow
  • Adjustable air nozzles
  • Permanently lubricated direct drive centrifugal motors and efficient blowers for maintaining appropriate face velocities of the air (6000 ft/min + 20 feet), while producing minimum vibrations and noise (less than 60 db)
  • Indicator lights on both sides of the air shower for regulation of traffic within the cubicle
  • Emergency buttons on both sides of the air shower to prevent accidental lock-outs
  • Interlocked doors minimize any chances of contamination
  • Door interlocks operate on the magnetic system
  • Hinged motor/blower compartment access panels made of coated aluminium
  • Tamper proof junction box, placed on top
  • Emergency switch off button with audible alarm located within the shower cubicle

Constructions Stainless Steel
Operation Time (Adjustable) 0-9,990 seconds
Pre Filter Washable pre-filter unit (Non-WovenSynthetic Polyester)
HEPA Filters Glass pleated non-woven fabric filter having 99.99% efficiency 0.3 micron particle size.
Air Flow One side/two side/tower flow/multidirectional
Face velocity 6000 ft./min + 20 feet
Air Flow Control Solid State Control Unit
Illumination Fluorescent light illumination greater than 800 lux on work table
Blower Assembly Centrifugal lubricated bearing type ISI marked assembly
Noise level Noise level less than 60 dB
Add on Features Sequential feature operation by door mat magnetic switch.
Power Requirements 500 watts – 950 watts (Model specific)
Nominal voltage 220-230 Volts,
Frequency 50/60 Hz
View Complete Details

Air Shower

Material Handling Air Showerare self-contained units, installed at the entrance of a clean room and other controlled environment chambers for minimizing the entry of dust particles and other particulate matters into the working area. TheMaterial Handling Air Showeris designed to provide and maintain clean room conditions for research applications and particle sensitive manufacturing processes. These energy efficient units are fully self-contained and well equipped to provide and sustain a highly sterile working environment. Our versatileAir Showersare quite adept at controlling the level of contamination for particle sensitive processes such as disc drive and semiconductor manufacturing, pharmaceutical drug testing and for research applications involving molecular biology and biochemical experiments, cell and tissue culture experiments etc.

They are available in both standard and customized designs to suit the requirements of the industry. The entireair showerassembly is HEPA/ULPA filtered, pre-wired and tested, ready to use with a simple plug-in, therefore providing an unmatched ease of operation. Moreover, the use of high quality construction materials ensures unparalleled manufacturing quality, whereas the highly efficient blowers and motors ensure long lasting dependable results.

3 types of configurations are available:

One side flow:The unit allows one-way operation, with the clean side door locked and the grey side door unlocked at the idle state. This mode of operation helps in controlling the flow of traffic in and out of the clean room for maintaining maximum sterility in the working area.

Two side flow:The unit allows both side flows, allowing the air showers to be activated in both the directions. The user can exit through the clean room door or the grey side door, without compromising the sanctity of the clean air environment. This mode of operation prevents the egress of harmful contaminants from the clean room to the outside environment, making the unit particularly useful in pharmaceutical industries, animal research laboratories and other applications that require working with harmful and biohazardous substances.

Tower flow:the flow is from the upper roof of the shower.

  • Programmable operating modes
  • Programmable mode of operation, pre-purge and shower time
  • Floor matting operated switch for sequential operation of the air shower
  • Fully washable pre-filters capable of removing around 85% of particulate matters
  • Highly efficient HEPA filters with around 99.99% filtration efficiency for removing particles as small as 0.3 microns and larger.
  • Both the doors are Interlocked and magnetically operated to prevent them from opening at the same time
  • The auto reset feature unlocks the doors to prevent accidental lockouts
  • The reset default function resets the program settings to default values
  • Microprocessor based controls for the set parameters, detection of errors and their display
  • The clean room/grey room settings can be reversed via microprocessor based controllers, eliminating the need for physical reorientation of the unit.
  • Permanently lubricated direct drive centrifugal motors and efficient blowers capable of maintaining appropriate face velocities of the air (6000 ft/min + 20 feet)
  • Multidirectional air flow for better reachability
  • Emergency override buttons on both sides of the air shower to release the doors even when the air shower cycle has not completed
  • Indicator lights for open doors
  • LED indicators for interlock and shower sequence
  • An administrator PIN can be set to prevent unauthorized access to the air shower settings
  • A maintenance function operates the fan continuously for service checks and air velocity measurements
  • Versatile usage
  • Ergonomic design
  • Reduced vibration levels
  • Low noise level < 60 db
  • Programmable operation
  • Calibration and protocol documentation
  • Conforms to the US Federal Standards

Constructions Stainless Steel
Operation Time (Adjustable) 0-9,990 seconds
Pre Filter Washable pre-filter unit (Non-WovenSynthetic Polyester)
HEPA Filters Glass pleated non-woven fabric filter having 99.99% efficiency 0.3 micron particle size.
Air Flow One side/two side/tower flow/multidirectional
Face velocity 6000 ft./min + 20 feet
Air Flow Control Solid State Control Unit
Illumination Fluorescent light illumination greater than 800 lux on work table
Blower Assembly Centrifugal lubricated bearing type ISI marked assembly
Noise level Noise level less than 60 dB
Add on Features Sequential feature operation by door mat magnetic switch.
Power Requirements 500 watts – 950 watts (Model specific)
Nominal voltage 220-230 Volts,
Frequency 50/60 Hz
View Complete Details

Vertical Laminar Air Flow

Vertical Laminar Air Floware conceptualized to provide a work area completely bathed in high efficiency perfect air, which is free from any kind of particulate contamination or impurities. These units are ideally suited in all the applications, requiring protection of biological specimens or products from the possible contamination during the process or test. OurLaminar Air Flow Benchis fast gaining popularity in other fields, such as pharmaceutical production, electronic industries and various other manufacturing applications.

A vertical clean bench pushes air through a HEPA filter which is located at the top of enclosure. The air is directed downward onto the work surface at a constant speed.

It is useful for various works that require maintenance of the cleanness and purity like plant tissue culture, examination and experimentation of precision electronic parts, medical science, entomology, pharmacy, agriculture sector, seed science, veterinary science.

A vertical clean bench, on the other hand, offers a pivoting glass sash as a safety measure. This sash offers personal protection and a physical barrier when working with chemicals. Vertical clean benches are common place in microbiology, forensic, biotech and many other industries, which utilizes them during procedures that require clean work area.

  • Durable & cost effective
  • Fluorescent tube light
  • HEPA filter /ULPA filters that allows unidirectional air flow preventing recirculation of molecules.
  • No gaps and joints to prevent accumulation of germs.
  • Air filters made up of mini plated non-woven fabric.
  • Balanced motor static as well as dynamic
  • 99.997% efficiency at 0.3 particle
  • Transparent Front Door (5mm)
  • Static Pressure Manometer
  • Built in U.V. Germicidal Light
  • Conforms to US Federal Standard 209 B
  • Microprocessor based controls (HMI+PLC as an option)
  • Aesthetically designed-Designed according to the standards and principles underlining industrys aesthetic values.
  • Corrosion Resistant interior and exteriors-Corrosion resistant coatings like epoxy coatings are applied inside and outside the laminar air flow to prevent against degradation due to moisture, salt spray, oxidation or exposure to a variety of environmental or industrial chemicals/ corrosive agents.
  • Energy Efficient WEIBER laminar air flow uses less energy to provide the same level of performance, comfort and convenience, thus making it energy conserving.
  • Sturdy Constructionlaminar air flow are built with robustness to withstand stress and strain, giving it long life and ability to perform in extreme stress environments.

Cabinet construction SS-304/PCRC SHEET
Frequency 50Hz
Nominal voltage 220-230 volts
Air flow Unidirectional
Noise pressure(dB) (A) <54dB
Pre filter unit Washable pre filter unit
Illumination Fluorescent light illumination greater than 800 lux
Power Requirements 500-750 watts
View Complete Details

Horizontal Laminar Air Flow

Horizontal Laminar Flowworkstations are designed to protect the product within the work area from airborne particulates in the ambient air. The regulated efflux of custom made laminar airflow supplies the work zone with ISO Class 5 air cleanliness to offer the best product production by a clean bench in the industry. TheHorizontal Laminar Flowworkstations pushes the air through a HEPA filter and directs the filtered air horizontally over the work surface at a constant speed, toward the operator.

Our versatile unit is useful for various works that require maintenance of the cleanness and purity like plant tissue culture, examination and experimentation of precision electronic parts, medical science, entomology, pharmacy, agriculture sector, seed science, veterinary science.

Horizontal Laminar Air Flowgenerally have a taller and therefore a larger loading and working area. This allows for instruments, like microscopes to be placed inside. They are typically the preferred selection for plant tissue culture, media plate preparation, electronics inspection, medical device assembly and pharmacy drug preparation. Because they do not provide protection to the user, they should not be used in conjunction with biohazardous material, toxins or radionuclides. One of the key benefits is the absence of a sash, which is an advantage when placing instruments and equipment inside. This cabinet also known asLaminar Air Flow Cabinet.

  • Durable & cost effective
  • Fluorescent tube light
  • HEPA filter /ULPA filters that allows unidirectional air flow preventing recirculation of molecules.
  • No gaps and joints to prevent accumulation of germs.
  • Air filters made up of mini plated non-woven fabric.
  • Balanced motor static as well as dynamic
  • 99.997% efficiency at 0.3 particle
  • Transparent Front Door (5mm)
  • Static Pressure Manometer
  • Built in U.V. Germicidal Light
  • Conforms to US Federal Standard 209 B
  • Microprocessor based controls (HMI+PLC as an option)
  • Aesthetically designed-Designed according to the standards and principles underlining industrys aesthetic values.
  • Corrosion Resistant interior and exteriors-Corrosion resistant coatings like epoxy coatings are applied inside and outside the laminar air flow to prevent against degradation due to moisture, salt spray, oxidation or exposure to a variety of environmental or industrial chemicals/ corrosive agents.
  • Energy Efficient WEIBER laminar air flow uses less energy to provide the same level of performance, comfort and convenience, thus making it energy conserving.
  • Sturdy Constructionlaminar air flow are built with robustness to withstand stress and strain, giving it long life and ability to perform in extreme stress environments.

Cabinet construction SS-304/PCRC SHEET
Frequency 50Hz
Nominal voltage 220-230 volts
Air flow Unidirectional
Noise pressure(dB) (A) <54dB
Pre filter unit Washable pre filter unit
Illumination Fluorescent light illumination greater than 800 lux
Power Requirements 500-750 watts
View Complete Details

CLEAN STOKER

Clean Stoker for Clean Room is designed to maintain the cleanliness integrity of clean room garments during storage. It can effectively purge and remove particles such as lint and dust ingress on the clothing fabric.

Clean Room Stoker features a quiet, direct drive, variable- speed blower mounted above a HEPA filter rated 99.99%0.3m, and delivers a continuous downstream that block the inrush of contaminants into the storage area, as a result, helps garments virtually free of particulates. Door of the scientific equipment is made available to make movable and curtain type.

  • Avoid Pollution
  • Easy installation
  • Available to make movable door and curtain type
  • Available to change the ventilation rate for need
  • Specious
  • Class Grade :Class ISO5-ISO8
  • Convenient for take clothes.
  • Easy installation & low price

Main Body Steel Plate with stoving varnish or stainless steel
Containment PVC or toughened glass
Door Curtain or movable door
Clothes Hange SUS304 or plastic
Capacity 20 pcs clean clothes
Cleanness Class 100
Overlength Class 100
Fuel Electric
Machine Type High Pressure Cleaner
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us