Recirculating chillers are the ideal solution when you need precise temperature control or cooling below ambient temperature. A compressor-based recirculating chiller offers outstanding performance and high reliability as well as quiet operation and ease-of-use. These chillers are used for controlled cooling of products, mechanisms and factory machinery in a wide range of industries.
hey are often used in the plastic industries , injection and blow molding, metal working, welding equipment, die-casting and machine tooling, chemical processing, pharmaceutical formulation, food and beverage processing, paper and cement processing, vacuum systems, X-ray diffraction, power supplies and power generation stations, analytical equipment, semiconductors, compressed air and gas cooling. They are also used to cool high-heat specialized items such as MRI machines and lasers, and in hospitals, hotels and campuses.
Outer construction | SS 304/PCRC |
Inner construction | SS 304 |
Temperature Sensitivity | 0.2°C or better |
Temp. Stability | ± 0.5°C |
Readability | 0.1 |
Temperature Range | -25°C to 150°C (Standard) |
Temperature Controller | Microprocessor based |
Display | LCD/LED (with 0.1°C resolution) |
Pump capacity | 15 LPM |
Pressure | 500-800 mbar |
Flow rate | >10LPM |
Filling Volume | Up to 8 Liters |
Cooling compressor | Air |
Dimension D x L x H | 31” x 42” x 64” |
Nominal Power | 500-650 W |
Nominal Voltage | 220-230 volts |
Frequency | 50 Hz |
Automatic De-icing system | Optional |
Timer (999 minutes of hours) | Optional |
Serial Port (Printer) | Optional |
Real Time Program | Optional |
Printer Report Program | Optional |
Refrigerated Fluid Chiller System cools various fluids such as water, water/glycol or oil down to, or below, the ambient temperature. These provide Stable and reliable cooling for many common heat removal applications, including laser etching, AA furnaces, ICP, rotary evaporators, vacuum systems, reaction vessels, plasma etching and condenser cooling. It can achieve cooling capacity of 2KW, 1.8KW, 1.6KW and 1.4KW, for diversity of applications.
Whether integrated into a machine or used as an auxiliary cooler, this system will tackle any cooling task and guarantees quality with utmost precision.
Temperature range | ℃ | -10~+40 | ||||
Temperature stability | ℃ | ±0.5 | ||||
Interior size | mm | 240W×280D×200H | ||||
Opening | mm | Ø90(Accessible for maintenance only) | ||||
Overall dimension | mm | 500W×660D×780H | ||||
Duty cycle | Continuous | |||||
Auxiliary and safety functions | ATC, temperature sensor failure cutoff and alarm, high-temperature cutoff and low temperature alarm, high/low pressure cutoff, and auto-restart after power failure | |||||
Power | AC220V±10%, 50Hz | |||||
Cooling capacity@20℃ambient | +20℃ | W | 1,400 | 1,600 | 1,800 | 2,000 |
5℃ | 600 | 900 | 800 | 1,100 | ||
-10℃ | 150 | 400 | 250 | 500 | ||
Maximum pump head | bar | 4.0 | 1.0 | 4.0 | 1.0 | |
Outer construction | PCRC | |||||
Inner construction | SS 304 |
Water cooled chiller is a refrigeration apparatus that produces cold water or water/glycol mix, to cool industrial process equipment or provide comfort cooling for buildings. A water chiller uses the evaporation of a refrigerant to cool the fluid through a heat exchanger. Weiber offers a large selection of water cooled chillers/heater with quality construction and innovative technology, serving a variety of industries. The size and type of equipment used varies from small pre-packed low temperature environmental chambers of only a few horsepower (kW) to large custom-designed and often field-erected systems ranging to several hundred horsepower (kW).
The larger units are by nature one-of-a-kind, designed and built for a specific purpose, for a specific duty at a precisely controlled low temperature condition. The large units use a combination of one, two or more refrigerants in open cascade arrangements to obtain the desired low temperature. 7 standard models are available to choose from however we have the capacity to customize the specification as per individual needs.
Temperature Range |
-40°C to +25°C |
Number of Channels |
1 |
Cooling Capacity |
3 KW at -35°C, 7.5 KW at -20°C |
Heating Capacity |
1.5 KW |
Temperature Stability |
± 0.5°C or better |
Fluid (HTF) |
Water / Glycol (Dowtherm SR-1) |
Reservoir Volume |
5 Gallons |
Pump: Flow at Pressure |
6 GPM at 65 PSI |
Input Power |
440/480VAC, 60Hz, 3ph, 20 Amp |
Configuration |
Indoor, Water cooled |
Temperature Range |
+8°C to +40°C |
Number of Channels |
1 |
Cooling Capacity |
44 KW at +8°C |
Heating Capacity |
3 KW |
Temperature Stability |
± 0.5°C or better |
Fluid (HTF) |
DI Water |
Reservoir Volume |
44 Gallons |
Pump: Flow at Pressure |
40 GPM at 50 PSI |
Input Power |
440/460VAC, 60Hz, 3ph, 30 amp |
Configuration |
Indoor, Water cooled |
Temperature Range |
+15°C to +30°C |
Number of Channels |
1 |
Cooling Capacity |
65 KW at +20°C |
Heating Capacity |
3 KW |
Temperature Stability |
± 0.05°C or better |
Fluid (HTF) |
Water |
Reservoir Volume |
60 Gallons |
Pump: Flow at Pressure |
110 GPM at 60 PSI |
Input Power |
440/480VAC, 60 Hz, 3ph, 60 amp |
Configuration |
Indoor, Water-cooled |
Temperature Range |
-20°C to +30°C |
Number of Channels |
1 |
Cooling Capacity |
2 KW at -5°C, 600 Watts at -20°C |
Heating Capacity |
3 KW |
Temperature Stability |
± 0.5°C or better |
Fluid (HTF) |
Fluorinert FC-77, Galden HT-90 |
Reservoir Volume |
5 Gallons |
Pump: Flow at Pressure |
2 GPM at 60 PSI |
Input Power |
208/240VAC, 60Hz, 3ph, 30 Amp |
Configuration |
Indoor, Water cooled |
Temperature Range |
-70°C to +125°C |
Number of Channels |
1 |
Cooling Capacity |
4 KW at -40°C, 450 Watts at -70°C |
Heating Capacity |
3 KW |
Temperature Stability |
± 0.5°C or better |
Reservoir Volume |
8 Gallons |
Pump: Flow at Pressure |
5 GPM at 65 PSI |
Input Power |
440/480VAC, 60Hz, 3ph, 30 Amp |
Configuration |
Indoor, Water cooled |
Temperature Range |
-30°C to +70°C |
Number of Channels |
2 |
Cooling Capacity |
5 KW Total, 2.5 KW each loop at -30°C, |
Heating Capacity |
3 KW each loop |
Temperature Stability |
± 1.0 °C or better |
Fluid (HTF) |
Ethylene Glycol / Water |
Reservoir Volume |
10 Gallons each loop |
Pump: Flow at Pressure |
8 GPM at 80 PSI |
Input Power |
440/480VAC, 60Hz, 3ph, 50 Amp |
Configuration |
Indoor, Water cooled |
Temperature Range |
+18°C to +32°C |
Number of Channels |
3 |
Cooling Capacity |
6 KW Total, 2 KW loops 1 & 2 |
Heating Capacity |
2 KW loops 1 & 2, 4 KW loop 3 |
Temperature Stability |
± 0.05°C or better |
Fluid (HTF) |
Water |
Reservoir Volume |
11 Gallons loops 1 & 2, 22 Gallons loop 3 |
Pump: Flow at Pressure |
5 GPM at 50 PSI loops 1 & 2 |
Input Power |
208/240VAC, 60Hz, 3ph, 70 Amp |
Configuration |
Indoor, Water cooled |
Industrial chillers (air cooled) is a refrigeration system used to cool a process fluid and dehumidifies air in industrial facilities. Air cooled chiller uses fans to dissipate the heat removed by the refrigeration system. The equipment works as an air conditioning system with the world's best standard A-type screw compressor and newly designed shell and tube heat exchanger that have powerful cooling ability, low noise, low vibration, high efficiency and high reliability. These are equipped where no source of liquid are available for cooling the condenser.
Air Cooled Chiller comes complete with PID microprocessor-controlled controller that utilizes fully proportional cooling and heating. The equipment offers low-stress refrigeration system, circulating pumps, R-134A CFC free refrigerant and fluid reservoir. WEIBER gives you an option to choose from the seven models as per the desired recirculating fluid and other technical parameters.We specialize in both standard as well as customized chillers to meet the demands in required areas.