Our Products
Leading Manufacturer, Supplier & Retailer of MICRO TIPS, INDIVIDUALLY WRAPPED, STERILE, PREMIUM PLUS PIPETTES, PP, FIXED PREMIUM PIPETTE, PP, PREMIUM PLUS MULTI-CHANNEL PIPETTE, PP and PREMIUM ELECTRONIC PIPETTE.
Code | Capacity (ml) | Colour | No. Per Case |
P10164 | 0.2 - 10 μl (Graduated) | Natural | 400 |
P10161 | 2 - 200 μl (Bevelled Graduated) | Natural | 400 |
P10163 | 100 - 1000 μl | Natural | 40 |
Specifiaction | Maximum permissible systematic error | Maximum permissible random error | |||||
Code | Capacity (μl) | Increment (μl) | Test Volume (μl) | Inaccuracy (±) | Inaccuracy (±) | Imprecision (±) | Inaccuracy (±) |
E11145 | 0.1 - 2.5 | 0.05 | 2.5 1.25 0.25 |
2.50% 3.00% 12.00% |
0.062μl 0.037μl 0.03μl |
2.00% 3.00% 6.00% |
0.05μl 0.0375μl 0.015μl |
E11107 | 0.5-10 | 0.1 | 10 5 1 |
1.00% 1.50% 2.50% |
0.1μl 0.175μl 0.025μl |
0.80% 1.50% 1.50% |
0.08μl 0.075μl 0.015μl |
E11108 | 2-20 | 0.5 | 20 10 2 |
0.90% 1.20% 3.00% |
0.18μl 0.12μl 0.06 |
0.40% 1.00% 2.00% |
0.08μl 0.10μl 0.04μl |
E11146 | 5 - 50 | 0.5 | 50 25 5 |
0.60% 0.90% 2.00% |
0.3μl 0.225μl 0.1μl |
0.30% 0.60% 2.00% |
0.15μl 0.15μl 0.1μl |
E11109 | 10-100 | 1 | 100 50 10 |
0.80% 1.00% 3.00% |
0.80μl 0.50μl 0.30μl |
0.15% 0.40% 1.50% |
0.15μl 0.20μl 0.15μl |
E11110 | 20-200 | 1 | 200 100 20 |
0.60% 0.80% 3.00% |
1.20μl 0.80μl 0.60μl |
0.15% 0.30% 1.00% |
0.30μl 0.30μl 0.20μl |
E11147 | 50 - 200 | 1.1 | 200 100 50 |
0.60% 0.80% 1.00% |
1.20μl 0.80μl 0.50μl |
0.15% 0.30% 0.40% |
0.15% 0.30% 0.2% |
E11111 | 100-1000 | 5 | 1000 500 100 |
0.60% 0.70% 2.00% |
6μl 3.50μl 2μl |
0.20% 0.25% 0.70% |
2μl 1.25μl 0.70μl |
E11134 | 1000-5000 | 50 | 5000 2500 1000 |
0.50% 0.60% 0.70% |
25μl 15μl 7μl |
0.15% 0.30% 0.30% |
7.5μl 7.5μl 3μl |
E11135 | 2000-10000 | 100 | 10000 5000 2000 |
0.60% 1.20% 3.00% |
60μl 60μl 60μl |
0.20% 0.30% 0.60% |
20μl 15μl 12μl |
Specifiaction | Maximum permissible systematic error | Maximum permissible random error | ||||
Code | Capacity (μl) | Test Volume (μl) | Inaccuracy (±) | Inaccuracy (±) | Inaccuracy (±) | Inaccuracy (±) |
E10001 | 5 | 5 | 1.3% | 0.065μl | 1.2% | 0.06μl |
E10002 | 10 | 10 | 0.8% | 0.08μl | 0.8% | 0.08μl |
E10003 | 20 | 20 | 0.6% | 0.12μl | 0.5% | 0.1μl |
E10004 | 25 | 25 | 0.5% | 0.125μl | 0.3% | 0.075μl |
E10005 | 50 | 50 | 0.5% | 0.25μl | 0.3% | 0.15μl |
E10006 | 100 | 100 | 0.5% | 0.50μl | 0.3% | 0.30μl |
E10007 | 200 | 200 | 0.4% | 0.80μl | 0.2% | 0.40μl |
E10008 | 250 | 250 | 0.4% | 1μl | 0.2% | 0.50μl |
E10009 | 500 | 500 | 0.3% | 1.5μl | 0.2% | 1.0μl |
E100010 | 1000 | 1000 | 0.3% | 3μl | 0.2% | 2.0μl |
Fixed Volume Pipette | ||||||
Code | Capacity (μl) | No. per Case | ||||
E10001 | 5 | 1 | ||||
E10002 | 10 | 1 | ||||
E10003 | 20 | 1 | ||||
E10004 | 25 | 1 | ||||
E10005 | 50 | 1 | ||||
E10006 | 100 | 1 | ||||
E10007 | 200 | 1 | ||||
E10008 | 250 | 1 | ||||
E10009 | 500 | 1 | ||||
E100010 | 1000 | 1 |
Specifiaction | Maximum permissible systematic error | Maximum permissible random error | |||||
Code | Capacity (μl) | Increment (μl) | Test Volume (μl) | Inaccuracy (±) | Inaccuracy (±) | Inaccuracy (±) | Inaccuracy (±) |
E11136 | 0.5-10 | 0.1 | 10 5 1 |
1.50% 2.50% 4.00% |
0.15μl 0.125μl 0.04μl |
1.50% 2.50% 4.00% |
0.15μl 0.125 0.04 |
E11137 | 5 - 50 | 0.5 | 50 25 5 |
1.00% 1.50% 3.00% |
0.50μl 0.375μl 0.15μl |
0.50% 1.00% 2.00% |
0.25 0.25 0.10 |
E11138 | 50 - 300 | 1 | 300 150 50 |
0.70% 1.00% 1.50% |
2.10μl 1.50μl 0.75μl |
0.25% 0.50% 0.80% |
0.75 0.75 0.40 |
8 - Channel Adjustable Premium Plus Pipettes | |||||||
Code | Capacity (μl) | No. per Case | |||||
E11136 | 0.5-10 | 1 | |||||
E11137 | 5 - 50 | 1 | |||||
E11138 | 50-300 | 1 |
Specifiaction | |||||||
Code | Capacity (μl) | Increment (μl) | Test Volume (μl) | Inaccuracy (±) | Inaccuracy (±) | ||
E11161 | 0.5-10 | 0.01 | 10 1 |
± 0.10 μl ± 0.035 μl |
± 1.0% ± 3.5% |
0.05 s.d. μl 0.03 s.d. μl |
0.5 CV% 3.0 CV% |
E11162 | 5-50 | 0.1 | 50 5 |
± 0.40 μl ± 0.15 μl |
± 0.8% ± 3.0% |
0.15 s.d. μl 0.125 s.d. μl |
0.3 CV%l 2.5 CV% |
E11163 | 30-300 | 1 | 300 30 |
± 1.8 μl ± 0.9 μl |
± 0.6% ± 3.0% |
0.6 s.d. μl 0.21 s.d. μl |
0.2 CV% 0.7 CV% |
E11164 | 100-1000 | 5 | 1000 100 |
± 6.0 μl ± 3.0 μl |
± 0.6% ± 3.0% |
2.0 s.d. μl 0.6 s.d. μl |
0.2 CV% 0.6 CV% |
S.D – Standard Deviation I CV – Coefficient of Variation | |||||||
Code | Capacity (μl) | No. per Case | |||||
E11161 | 0.5-10 | 1 | |||||
E11162 | 5.0 - 50 | 1 | |||||
E11163 | 30-300 | 1 | |||||
E11164 | 100-1000 | 1 |
Specifiaction | ||
Code | Place | No. per Case |
E11161 | 6 | 1 |
Specifiaction | |||||||
Syringe Volume (ml) | Test Volume (μl) | A% | P% | ||||
0.50 | 10 | 20 | 30 | 40 | 50 | 0.8 | 0.7 |
1.25 | 25 | 50 | 75 | 100 | 125 | 0.8 | 0.5 |
2.50 | 50 | 100 | 150 | 200 | 250 | 0.8 | 0.4 |
5.00 | 100 | 200 | 300 | 400 | 500 | 0.4 | 0.3 |
12.50 | 250 | 500 | 750 | 1000 | 1250 | 0.3 | 0.3 |
25.00 | 500 | 1000 | 1500 | 2000 | 2500 | 0.2 | 0.3 |
50.0 | 1000 | 2000 | 3000 | 4000 | 5000 | 0.2 | 0.2 |
Dial Setting | 1 | 2 | 3 | 4 | 5 | ||
Number of steps | 48 | 23 | 15 | 11 | 8 | ||
Suitable Tips & Adapter for Stepmate Stepper | |||||||
Code | Capacity (μl) | Colour | No. per Case | ||||
P11090 | 0.5 | Natural | 5 | ||||
P11091 | 1.25 | Natural | 5 | ||||
P11092 | 2.5 | Natural | 5 | ||||
P11093 | 5 | Natural | 5 | ||||
P11094 | 12.5 | Natural | 5 | ||||
P11095 | 25 | Natural | 2 pcs piston + 1 pcs adaptor | ||||
P11096 | 50 | Natural | 2 pcs piston + 1 pcs adaptor | ||||
P11097 | 25 & 50 Adaptor | Natural | 10 | ||||
* The first and last dispensing liquid should be discarded for precision. |
Code | Capacity (ml)) | No. Per Case |
E11218 | 10 | 4 |
E11216 | 25 | 4 |
Code | Capacity (ml) | Length (mm) | No. Per Case |
P31201 | 1.0 | 150 | 500 |
P31202 | 1.0 (Sterile) | 150 | 500 |
P31205 | 3.0 | 155 | 500 |
P31206 | 3.0 (Sterile) | 155 | 500 |