Automatic Modular Fire Extinguisher

  • 5KG | 10kg Stored Pressure
  • Dry Powder (ABC/BC Powder Conforming To IS 14609 / IS 4308) or HFC 227 ea Based Clean Agent Nitrogen
  • 57°C Onwards As Per Requirement 8-10 | 10-15
  • 3-4m2 – 5-7m2 27 kg/cm2
Application Areas:

Stock Godowns, Material Stocks, Paper, Wood, Textiles, Rubber, Plastic, Oil, Petrol, Paint, Petrochemical Products, Resins, Compressed Gases Like Acetylene, LPG, CNG.

View Complete Details

Carbon Dioxide Gas Extinguisher

  • 2 KG CO21012
Application Areas:

Fires Involving all Flammable Liquids, Gases, Machinery Fires, Electrical and Sophisticated Electronic Equipment Fires, Transformer and Switch Gear Fires, Etc.,

CAPACITY 2 KG 4.5 KG 6.5 KG
INDIAN STANDARD IS 15683
ISI MARK Yes Yes Yes
TYPE Stored Pressure
EXTINGUISHER MEDIA Carbon Dioxide Gas Conforming To IS 15222
EXPELLANT Self Expelling
FILLING RATIO, MAX 0.667
OPERATING TEMPERATURE -10 To +55°C -10 To +55°C -30 To +55°C
MINIMUM EFFECTIVE DISCHARGE (%) More Than 95 Percent
THROW MINIMUM 1 Meter 1 Meter
DISCHARGE TIME (SECS) MINIMUM 8 8 10
RESISTANCE TO VIBRATION Yes Yes N/A
FIRE RATING 8B 13B N/A
View Complete Details

Water Fire Extinguisher

  • 6 Liters  WC02106 
Application Areas:

All A Class Fires which involve Material like Wood, Paper, Cloth, Fiber, Plastic, Rubber Etc.,

CAPACITY 6 Liters 9 Liters
INDIAN STANDARD IS15683
ISI MARK Yes Yes
TYPE Stored Pressure
EXTINGUISHER MEDIA Water
EXPELLANT Nitrogen Nitrogen
OPERATING TEMPERATURE -10 To +55°C
MINIMUM EFFECTIVE DISCHARGE (%) More Than 95 Percent
HYDRAULIC TEST PRESSURE 27 kg/cm2 27 kg/cm2
THROW (MINIMUM) 2 Meters 2 Meters
DISCHARGE TIME (SECS) MINIMUM 13 13
RESISTANCE TO IMPACT Yes Yes
RESISTANCE TO VIBRATION Yes Yes
TABBING TEST (500 STROKES) Conforms Conforms
RESISTANCE TO CORROSION (SALT SPRAY TEST) Yes Yes
FIRE RATING 3A 3A
View Complete Details

Dry Powder Fire Extinguisher

  • 6 KG  DCP1016 
Application Areas:

All B and C Class Fires Like Oil, Petrol, Diesel, Solvents, Chemicals, Varnishes, Chemical Liquids, all Flammable Liquids and fires resulting from Gases Like Acetylene, LPG, CNG Etc.,

CAPACITY 6 Liters 9 Liters
INDIAN STANDARD IS15683
ISI MARK Yes Yes
TYPE Stored Pressure
EXTINGUISHER MEDIA Dry Powder (BC Powder Conforming To IS 4308)
EXPELLANT Nitrogen Nitrogen
OPERATING TEMPERATURE -10 To +55°C
MINIMUM EFFECTIVE DISCHARGE (%) More Than 90 Percent
HYDRAULIC TEST PRESSURE 27 kg/cm2 27 kg/cm2
THROW (MINIMUM) >2M >2M
DISCHARGE TIME (SECS) MINIMUM 8 8
RESISTANCE TO IMPACT Yes Yes
RESISTANCE TO VIBRATION Yes Yes
TABBING TEST (500 STROKES) Conforms Conforms
RESISTANCE TO CORROSION (SALT SPRAY TEST) Yes Yes
View Complete Details

Mechanical Foam Fire Extinguisher

  • 6 Liters  MF1016 
Application Areas:

All A and B Class Fires Involving Wood, Paper, Textiles, Stationary, Volatile Liquids Like Oil, Petrol, Diesel, Kerosene, Solvents and Chemicals, Wax, Resins and Other Petrochemical Products Etc.,

CAPACITY 6 Liters 9 Liters
INDIAN STANDARD IS15683
ISI MARK Yes Yes
TYPE Stored Pressure
EXTINGUISHER MEDIA Aqueous Film Forming (AFFF) Conforming To IS 4989
EXPELLANT Nitrogen Nitrogen
OPERATING TEMPERATURE -10 To +55°C
MINIMUM EFFECTIVE DISCHARGE (%) 95%
HYDRAULIC TEST PRESSURE 27 kg/cm2 27 kg/cm2
THROW (MINIMUM) 2 Meters 2 Meters
DISCHARGE TIME (SECS) 13 13
RESISTANCE TO IMPACT Yes Yes
RESISTANCE TO VIBRATION Yes Yes
TABBING TEST (500 STROKES) Conforms Conforms
RESISTANCE TO CORROSION Yes Yes
FIRE RATING 3A 34B
View Complete Details

Home Fire Extinguisher

  • Discharge Range 2 Meters
  • 2 KG Stored Pressure
  • Dry Powder (ABC Powder Conforming To IS 14609) Nitrogen
  • -10 To +55°C More Than 90 Percent
  • 8 Yes
  • Yes Conforms
  • Yes 1A, 8B
Application Areas:

Suitable for Homes, Apartments, Bungalows, Villas, Resorts, Hotel Rooms Etc.,

View Complete Details

Kitchen Fire Extinguisher

  • 2 KG Stored Pressure
  • Dry Powder (BC Powder Conforming To IS 4308) Nitrogen
  • -10 To +55°C More Than 90 Percent
  • 27 kg/cm2 2 Meters
  • 8 Yes
  • Yes Conforms
  • Yes 1A, 8B
Application Areas:

For B and C Class Fire and at all places involving use of Cooking Fats and Oils at High Temperatures Like Canteens, Hotels, Restaurants, Food Courts, all Small and Big Kitchens Etc.,

View Complete Details

Multipurpose ABC Trolley Mounted Fire Extinguishers

Application Areas:

Papers, Wood, Textiles, Rubber, Plastics, Oil, Petrol, Paint, Petrochemical Products, Resins, Compressed Gases Like Acetylene, LPG, CNG, Electrical and Sophisticated Electronic Equipments.

CAPACITY 25 KG 50 KG
INDIAN STANDARD IS 10658
TYPE Cartridge / Co2 Cylinder
EXTINGUISHER MEDIA Dry Powder (ABC Powder Conforming To IS 14609)
EXPELLANT Co2 Gas Co2 Gas
OPERATING TEMPERATURE N/A
MINIMUM EFFECTIVE DISCHARGE (%) More Than 85 Percent
HYDRAULIC TEST PRESSURE 30 kg/cm2 30 kg/cm2
DISCHARGE TIME (SECS) 25-30 40-50
RESISTANCE TO IMPACT N/A N/A
RESISTANCE TO VIBRATION N/A N/A
TABBING TEST (500 STROKES) N/A N/A
RESISTANCE TO CORROSION (SALT SPRAY TEST) N/A N/A
View Complete Details

Vehicle Fire Extinguisher

  • Discharge Range 2 Meters
  • 2 KG 15683
  • Yes Stored Pressure
  • Dry Powder (ABC Powder Conforming To IS 4308) Nitrogen
  • -10 To +55°C More Than 90 Percent
  • 8 Yes
  • Yes Conforms
  • Yes 1A, 8B