Our Product / Services
Industrial Machinery
2 Products availableLOAD CELL REPAIRING SERVICES
2 Services availableElectrical & Electronic Testing Devices
1 Products availableWe are leaders in the market for providing best range of Digital Indicator Repair Service, AARCH Load Cell and S Type Load Cells
For any Digital Indication - Repair for Digital Indicator require to be use with Load Cells, Electronic weighing system, Multi weigh feeder, Tensile Testing system, Peak Testing System.
Digital Indiactor can be available with RS232, RS485, Multi Load Cell junstion included, 0-5 volt & 4-20 MAmp conversion.
we have carved a niche in the market as the manufacturer, repairer & supplier of stainless steel s type load cells. we are based in maharashtra, india. the s type load cells we offer are used for conversion systems in various industries. we check the s type load cells on stringent quality parameters before the final delivery. buyers can acquire the s type load cells from us at reasonable prices.
applications : suspended hooper weighing force measurement, tension/ compression, tensile testing, material testing, hybrid scale, crane scale, process weighting, industrial automation.
Additional Information:
Payment Terms : T/T,
Technical Specifications
All Dimensions are in MM | ||||
Capacity | Height | Length | Width | Thread |
2 kg to 50 kg. | 75 | 50 | 16 | M-8 |
100 kg to 750 kg. | 75 | 50 | 20 | M-10 |
1 T to 5 T | 100 | 75 | 35 | M-20 |
7.5 to 10 Ton | 175 | 125 | 50 | M-33 |
15 T, 20 T | 175 | 125 | 70 | M-42 |
30 T | 230 | 190 | 85 | M-42 |
|
||||
O/P | 2 mV/V # | |||
Non Linearity | < ± 0.02%of Rated Load | |||
Repeatability | < ± 0.02%of Rated Load | |||
Hysteresis | < ± 0.02%of Rated Load | |||
Creep@30 Min. | < ± 0.02%of Rated Load | |||
Zero Balance | < ± 2%of Rated Load | |||
Total Error | < ± 0.03% of Rated Load | |||
I/P Impedance | 417 Ohms ± 15 Ohms | |||
O/P impedance | 350 Ohms ±5ohms | |||
Insulation Impedance | 1000 M Ohms@50VDC | |||
Service Load | 100% of Rated Load | |||
Safe Over Load | 150% of Rated Load | |||
Ultimate Over Load | 200% of Rated Load | |||
Tempt. Effect on Zero | < 0.002% of Rated Load /°C | |||
Tempt. Effect on O/P | < 0.002% of Rated Load /°C | |||
Deflection | <0.5 mm at Full load | |||
# 3mV/V Optional |