Our Products
Generators, Turbines & Power Plants
2 Products availableVoltage Stabilizer
1 Products availableLamps
1 Products availableFuses, Circuit Breakers & Components
1 Products availableSwitch Gears
1 Products availableElectrodes
1 Products availableProcess Control Systems & Equipment
1 Products availableDomestic Fans, AC & Coolers
1 Products availableGenerators
1 Products availableSolar Water Heater
1 Products availableOur product range contains a wide range of condensed milk plants, Electronics Products and power products
We design, manufacture, installation and commissioning of DG synchronization panel. Electricity is prominent need of todays competitive market and everyone wants continuous power supply that is making possible through synchronization of DG sets (emergency supply) with mains supply.
We are providing DG to DG synchronization, DG to MAINS (GRID) synchronization and Reverse synchronization that is base load generation in auto and manual mode both.
We are providing wide range of DG synchronization panel ranges from 35 kVA to 1000 KVA and above. We are providing solution to clients existing system as well as plan system through advance engineering skills.
Our synchronizing Panel is designed and manufactured as per IP standards. This panel is manufactured using quality components and the latest control system.
INTRODUCTION: Indotech Introduces the Surge Protection Device For the Power Line. This Document Introduces about the Brief Description of technical specifications, installation, inspection, application and the maintenance of Surge Protection Devices of Surge Protection Devices of Class B and Class C and Combo.
The First Stage of the protection provided before the equipment at mains distribution panel is called as Class B type .This type of the Protection shall be provided against the LighteningElectromagnetic Pulse(LEMP) and other high surges at the Power Distribution Panel. The Device is designed and manufactured to handle the lightening current pulses of 10/350 . The class B Protects the AC Power System against the Lightening. This is the Separate Wall Mounted System which is to be installed at the Power Input Point at the ACDB/LT Panel. This equipment consists of the Class B Protection Device and the Protective MCB of suitable rating with the Proper termination of the Line, Neutral and Earthling Connections. Following table shows the technical specifications of the Class B Protection Equipment.This type of protection device is provided against the low voltage surges at the equipment input level connected between line and neutral . The Device is designed and manufactured to handle the lightening current pulses of 8/20 . The class C Provides the protection for the appliances in the AC Power System against the Low voltage surge . This is the Separate Wall Mounted System which is to be installed near to appliance or the sensitive equipment but at the minimum 15 meter distance from the class B Protection. This equipment consists of the Class B Protection Device and the Protective MCB of suitable rating with the Proper termination of the Line , Neutral and Earthling Connections. Following table shows the technical specifications of the Class C Protection.
We design and manufacture automatic power factor correction panel. (contactor switching) Power Factor is ratio which represents actual power dissipated in A.C. circuit to the product of R.M.S. voltage and current. The phase difference between voltage and current is caused by reactance in circuit and represents power that does no useful work.
Power factor is low in industrial settings where most of the plant energy is used to power electric motors. It is lowest when the induction motors tend to be oversized and under-loaded. A lagging (less than 1.0) power factor causes some additional energy loss because more current is required to deliver a required amount of power. Correcting power factor can be an appropriate and cost-effective measure.
Inductive load is major cause of poor factor and which is responsible for unnecessarily power loss, hence it results in rise of electricity bills of industrial, commercial consumer so Reactive power compensation is very need of todays industries. We can easily control and maintain power factor near to unity with Automatic Power Factor Correction Panel.
We are blessed with solar energy in abundance at no cost. Thats why to utilize this god gifted energy and to help you to reduce your daily expenses considerably Indotech has come forward with an effective system of Solar water Heaters. With their simple design and effective water heating capability it has already proven best solution for electric heaters and gas geysers. Being an eco-friendly energy source it automatically leads us toward achieving a goal of clean environment.
We are engaged in the supply of ice bank tank that are in high demand in the domestic market. Manufactured from superior quality SS (304) these are used for dairy, Chilled milk tank, Plate heat exchanger, etc. Moreover we faithfully satisfy our clients offering customized ranges adhering to their designs and specifications.
Features :A Diesel Generator is used to generate electrical energy. It is the combination of a diesel engine with an electric generator (alternator) .Diesel generators are used as source of emergency power supply when there is failure in grid power. Diesel generators are also used in Co-gen plant in sugar factory, when grid fails Diesel generators are used.
Application Area :We are the prominent Manufacturer and Supplier of Uninterrupted Power Supply (UPS) in nationwide markets. The ability to perform in hardcore industrial applications has earned the huge popularity to our Uninterrupted Power Supply (UPS). We provide availability of Uninterrupted power supply that is viable with digital display which can be obtained at cost effective prices.
We offer Milk chiller to keep the temperature of milk to 4 C. Chiller is a machine that removes heat from a liquid. This liquid can be circulated through a heat exchanger to cool air or equipment as required. As a necessary byproduct, refrigeration creates waste heat that must be exhausted to ambient or, for greater efficiency, recovered for heating purposes. Concerns in design and selection of chillers include performance, efficiency, maintenance and product life cycle environmental impact.
We are leading manufacturer of MCC Panel. Motor Control Centre consist of DOL starter for an induction motor upto 5HP and star-delta starter above 7.5 HP motor. Contactor based starter provides overload protection and allow to smooth start of an induction motor and also limit its higher starting current.
We are provide both indoor and outdoor mcc panel which gives IP65 protection. Our panel follows all IEC standards of panel fabrication with quality and security. MCC panel also provide facility of remote starting and controlling of motor so it will become so much easy to control number of motor from single compact panel.
Aviation Obstruction Light ideally suitable for installation on communication Towers (GSM, CDMA & Radio), Buildings, Industrial exhaust chimney, and Aviation control towers. This is Low Energy Consumption LED based Aviation Obstruction light with Single and Double Dome for respective applications. All the models are designed & developed as per ICAO Norms.
Auto mains failure (AMF) Panels is meant for controlling DG START / STOP sequence in accordance to the availability of utility power supply. We design & manufacture the AMF panels for various capacity & different make of Diesel EA set.
Indotech introduces AMF Controller, which is a micro-controller based product that is meant to protect and control of a Diesel Generator in absence of mains power supply. It Monitors mains supply and if there is any voltage unbalance or phase failure it transfers load to DG by making it ON, considering all parameters that are associated with DG. Fur5thermore, it contains a three phase AC voltage measuring circuit and is equipped with LCD display and 4, 7 Segment Display presenting all values and alarms.
The Earthing Electrode diameter and the thickness of the strip depends on the soil conditions as well as the application load .It will be of 2mtrs and 3mtrs in length depending upon the soil condition and application load.
For 2 Mtrs electrode 1 Bag of Earth Enhance Compound is required. For 3 Mtrs electrode 2Bags of Earth Enhance Compound are required. The quantity of Compound. may increase depending upon the soil conditions.
FEATURES :Indotech introduces AC Protector designed for safety of Air conditioners. It monitors healthy/abnormal conditions Mains supply. This AC controller helps in reducing the power consumption and wear & tear of Air Conditioners. It has been also provided with advanced feature of GSM communication, which will give alarm status or all parameter status on cellphone (through SMS) as per user requirement.
Indotech offers Milk powder Plant for capacity 50 kg/h to 50 ton/day powder production.
Drying process extends the shelf life of milk and also reduces the weight and volume. Drying reduces the transportation cost.
Milk concentrated up to 45 % solid concentration in multiple effects falling milk evaporator with TVR system.
We offer reliable corrections against the voltage fluctuations to the valuable devices connected to raw electricity SVR uses the advanced micro controller based digital controller to control the high speed MOSFET & IGBTs for the basic voltage correction rate & speed correction also. The complete absence of moving parts demand zero maintenance, enhance reliability thereby further reducing service trips & network down time man days. These true RMS based static stabilizers are specially design as per requirements & specifications of user.
Indotech introduces lightning arrester that provides three phase comprehensive for grounding solution and lightning protection. Our system is single point grounding system. We design lightning arrester to give maximum protection against direct lightning strikes.Charge dissipation technology uses the point discharge principle to facilitate the dissipation of a build-up of static charges. The sole purpose of static dissipation product is to reduce the accumulation of electrical charges and thereby prevent an electrical arc or an electrical current flow that can cause damage.
This same technology has been successfully applied to the lightning protection industry by developing product line that can be mounted on the structures to reduce the accumulation of ground charge.
A single point, such as on a lightning rod or as occurs on a corner of tower or structure will reach a point of saturation of extent that it cannot disperse charge at fast enough rate to keep up with the charge accumulation. These areas then become the points where steamers will form, thereby attracting a lightning strike to themselves.